HPN-ICF-EOC-COMMON-MIB
136 objects
The objects in this MIB module are used to manage and display common configuration between Ethernet Passive Optical Network (EOC) port which are based on the Ethernet in the First Mile (EFM) Passive Optical Network(PON) as defined in IEEE Draft P802.3ah/D3.0 clause 60, 64, 65.. and Ethernet Over Cable (EOC) which is based on HomePlug AV Specification.
Imported Objects
| HPN-ICF-HPEOC-MIB | hpnicfHPEOCDownLoadCNUFWResult |
| HPN-ICF-OID-MIB | hpnicfCommon |
| IANAifType-MIB | IANAifType |
| IF-MIB | ifDescr ifIndex |
| SNMPv2-SMI | Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString MacAddress RowStatus TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.83 | IdentityhpnicfEOCCommon | The objects in this MIB module are used to manage and display common configuration between Ethernet Passive Optical Network (EOC) port which are based on the E… | ||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.1 | NodehpnicfEOCCommonSysMan | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.1.1 | NodehpnicfEOCCommonSysScalarObjects | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.1.1.1 | ScalarhpnicfEOCCommonSysVersion | read-only | current | Eoc version. If the object length is zero, it means the version is unknown. The length is up to 1024. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.1.1.2 | ScalarhpnicfEOCCommonUpLinkMacAddress | read-only | current | EOC CLT's uplink device's mac address. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.2 | NodehpnicfEOCCommonCltMan | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.2.1 | TablehpnicfEOCCommonCltManTable | not-accessible | current | This table defines the primary parameters of the CLT configuration. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.2.1.1 | RowhpnicfEOCCommonCltManEntry | not-accessible | current | The entry of the table hpnicfEOCCommonCltManTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.2.1.1.1 | ColumnhpnicfEOCCommonCltAutoAuthorize | read-write | current | This value determines whether software performs self-authorization for each Cable Network Unit(CNU) registering to the network. Setting it to false means for e… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.2.1.1.2 | ColumnhpnicfEOCCommonCltMaxAllowToAccess | read-write | current | This value determines how many CNU can be bound in this CLT. If the number of CNU is more than this value , then the rest of CNU should not be allow to access. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3 | NodehpnicfEOCComCnuMan | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1 | NodehpnicfEOCComCnuScalarObjects | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.1 | ScalarhpnicfEOCComCnuMaxDownBWMinVal | read-only | current | The lower limit of total-bandwidth which is confined to hpnicfEOCComCnuMaxDownBW. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.2 | ScalarhpnicfEOCComCnuMaxDownBWMaxVal | read-only | current | The upper limit of total-bandwidth which is confined to hpnicfEOCComCnuMaxDownBW. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.3 | ScalarhpnicfEOCComCnuSlaHighPriBWMinVal | read-only | current | The lower limit of high priority bandwidth which is confined to hpnicfEOCComCnuSlaHighPriBW. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.4 | ScalarhpnicfEOCComCnuSlaHighPriBWMaxVal | read-only | current | The upper limit of high priority bandwidth which is confined to hpnicfEOCComCnuSlaHighPriBW. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.5 | ScalarhpnicfEOCComCnuMaxUpBWMinVal | read-only | current | The lower limit of total-bandwidth which is confined to hpnicfEOCComCnuMaxUpBW. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.6 | ScalarhpnicfEOCComCnuMaxUpBWMaxVal | read-only | current | The upper limit of total-bandwidth which is confined to hpnicfEOCComCnuMaxUpBW. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.7 | ScalarhpnicfEOCComCnuAttenThrA | read-write | current | The value of cnu's average attenuation good level thresholds. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.8 | ScalarhpnicfEOCComCnuAttenThrB | read-write | current | The value of cnu's average attenuation normal level thresholds. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.1.9 | ScalarhpnicfEOCComCnuRateDropThr | read-write | current | The value of cnu's Tx/Rx rate drop thresholds. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2 | TablehpnicfEOCComCnuSysManTable | not-accessible | current | This table implements the management of CNUs(Coax Network Unit). |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1 | RowhpnicfEOCComCnuSysManEntry | not-accessible | current | The entry of the table hpnicfEOCComCnuSysManTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.1 | ColumnhpnicfEOCComCnuCableIfindex | read-only | current | The index of cable port which uniquely identifies the cable port of one device. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.2 | ColumnhpnicfEOCComCnuDeviceType | read-write | current | The type of the EOC CNU(Coax Network Unit). |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.3 | ColumnhpnicfEOCComCnuDeviceAlias | read-write | current | EOC CNU's alias which display as the device's name, it's recommended to set it uniquely and understandably. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.4 | ColumnhpnicfEOCComCnuDescr | read-write | current | User's description, including user's address, name, telephone number and so on. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.5 | ColumnhpnicfEOCComCnuUpTime | read-only | current | The time since the CNU last registered to the network. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.6 | ColumnhpnicfEOCComCnuVLANType | read-write | current | port vlan types. hybrid (3) port can carry multiple VLANs. If fabric function is supported, fabric(4) means the port is a fabric port. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.7 | ColumnhpnicfEOCComCnuPvid | read-write | current | The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on cable interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.8 | ColumnhpnicfEOCComCnuVlanTag | read-write | current | VLAN is set tagged or untagged on cable interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.9 | ColumnhpnicfEOCComCnuReset | read-write | current | This variable is used to reset the CNU device. The interface may be unavailable while the reset occurs and data may be lost. During reading operation it return… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.10 | ColumnhpnicfEOCComCnuDeregister | read-write | current | deregister CNU. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.11 | ColumnhpnicfEOCComCnuSave | read-write | current | Save the UNI and CNU related configurations to the CNU. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.2.1.12 | ColumnhpnicfEOCComCnuAccess | read-write | current | Control whether the user can access to the network. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.3 | TablehpnicfEOCComCnuMacTable | not-accessible | current | This table implements the management of CNUs. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.3.1 | RowhpnicfEOCComCnuMacEntry | not-accessible | current | The entry of the table hpnicfEOCComCnuMacTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.3.1.1 | ColumnhpnicfEOCComCnuMacAddress | read-create | current | EOC CNU's MAC address. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.3.1.2 | ColumnhpnicfEOCComCnuRowStatus | read-create | current | Operation status. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.3.1.3 | ColumnhpnicfEOCComCnuTempIndex | read-write | current | EOC CNU's model index from hpnicfHPEOCTemplateIndex, If configure 0, the CNU select no model. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4 | TablehpnicfEOCComCnuInfoTable | not-accessible | current | Primary status of the specified CNU. There will be one row in this table for each information in the system. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1 | RowhpnicfEOCComCnuInfoEntry | not-accessible | current | The entry of the hpnicfEOCComCnuInfoTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.1 | ColumnhpnicfEOCComCnuHardwareVersion | read-only | current | EOC CNU's hardware version. If the object length is zero, it means the version is unknown. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.2 | ColumnhpnicfEOCComCnuPCBVersion | read-only | current | EOC CNU's PCB version. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.3 | ColumnhpnicfEOCComCnuLinkState | read-only | current | The cable port's link state. The physicaldown(1) state indicates that the CNU is not powered on. The linkdown(2) state indicates that the CNU is powered on, bu… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.4 | ColumnhpnicfEOCComCnuAttenuation | read-only | current | The cnu's average attenuation. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.5 | ColumnhpnicfEOCComCnuSoftwareVersion | read-only | current | EOC CNU's software version. If the object length is zero, it means the version is unknown. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.6 | ColumnhpnicfEOCComCnuTxRate | read-only | current | The cnu's capability of tx speed in unit of 1Mbps. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.7 | ColumnhpnicfEOCComCnuRxRate | read-only | current | The cnu's capability of rx speed in unit of 1Mbps. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.8 | ColumnhpnicfEOCComCnuTxRateDrop | read-only | current | The cnu's capability droping of tx speed from it's history max value in unit of %. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.4.1.9 | ColumnhpnicfEOCComCnuRxRateDrop | read-only | current | The cnu's capability droping of rx speed from it's history max value in unit of %. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.5 | TablehpnicfEOCComCnuBandWidthTable | not-accessible | current | Set bandwidth parameters. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.5.1 | RowhpnicfEOCComCnuBandWidthEntry | not-accessible | current | The entry of table hpnicfEOCComCnuBandWidthTable. It is a pre-configuration. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.5.1.1 | ColumnhpnicfEOCComCnuMaxDownBW | read-write | current | Maximum bandwidth allowed for the CNU, measured in Kbit/s. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.5.1.2 | ColumnhpnicfEOCComCnuSlaHighPriBW | read-write | current | High priority bandwidth - measured in Kbit/s. The value of this object should be the multiple of the value of hpnicfEOCComCnuMaxUpBW. The high priority bandwid… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.3.5.1.3 | ColumnhpnicfEOCComCnuMaxUpBW | read-write | current | Total bandwidth - measured in Kbit/s. The value of this object should be the multiple of the value of hpnicfEOCComCnuSlaHighPriBW. The total bandwidth should b… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4 | NodehpnicfEOCComUniMan | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1 | TablehpnicfEOCComUniManTable | not-accessible | current | This table defines several user network interface(UNI) system parameters. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1 | RowhpnicfEOCComUniManEntry | not-accessible | current | The entry of hpnicfEOCComUniManTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.1 | ColumnhpnicfEOCUniIndex | not-accessible | current | The index value which uniquely identifies the FE(Fast Ethernet) interface of the CNU. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.2 | ColumnhpnicfEOCComUniDescr | read-only | current | A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the i… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.3 | ColumnhpnicfEOCComUniStatus | read-write | current | The desired state of the user network interface. When a managed system initializes, all user network interfaces start with down state. The testing state indica… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.4 | ColumnhpnicfEOCComUniSpeed | read-write | current | User network interface speed. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.5 | ColumnhpnicfEOCComUniDuplex | read-write | current | User network interface mode. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.6 | ColumnhpnicfEOCComUniCurrentSpeed | read-only | current | An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation ca… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.7 | ColumnhpnicfEOCComUniCurrentDuplex | read-only | current | The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mod… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.8 | ColumnhpnicfEOCComUniMdi | read-write | current | Type of the line connected to UNI interface: mdi-ii(straight-through cable), mdi-x (crossover cable), mdi-auto (auto-sensing). |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.9 | ColumnhpnicfEOCComUniFlowControl | read-write | current | Flow control status. true(1) - Flow control status enable. false(2) - Flow control status disable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.10 | ColumnhpnicfEOCComUniCountReset | read-write | current | Reset the counter which is about packets of the interface, then the counter will change to zero. There is no sense in reading this object. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.11 | ColumnhpnicfEOCComUniAlias | read-write | current | This object is an 'alias' name for the interface as specified by a network manager, and provides a non- volatile 'handle' for the interface. On the first insta… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.12 | ColumnhpnicfEOCComUniType | read-only | current | The type of interface. Additional values for hpnicfEOCComUniType are assigned by the Internet Assigned Numbers Authority(IANA), through updating the syntax of … |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.13 | ColumnhpnicfEOCComUniVLANType | read-write | current | port vlan types. hybrid (3) port can carry multiple VLANs. If fabric function is supported, fabric(4) means the port is a fabric port. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.14 | ColumnhpnicfEOCComUniPvid | read-write | current | The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on this port. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.15 | ColumnhpnicfEOCComUniVlanTag | read-write | current | VLAN is set tagged or untagged. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.16 | ColumnhpnicfEOCComUniPriority | read-write | current | The default ingress User Priority for this port. This only has effect on media, such as Ethernet, that do not support native User Priority. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.17 | ColumnhpnicfEOCComUniUpLineRate | read-write | current | The max speed upload in units of 1,000 bits per second on this interface. The value should between 0 and 100Mbps. If the value is 0, it means that the upload s… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.18 | ColumnhpnicfEOCComUniDownLineRate | read-write | current | The max speed download in units of 1,000 bits per second on this interface. The value should between 0 and 100Mbps. If the value is 0, it means that the downlo… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.1.1.19 | ColumnhpnicfEOCComUniAdminStatus | read-write | current | Control if open or close the UNI. If choose up(1), means the UNI is opened and packets can pass it. If choose down(2), means the UNI is closed and all packets … |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2 | TablehpnicfEOCComUniCountTable | not-accessible | current | A list of interface counter about frames entries. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1 | RowhpnicfEOCComUniCountEntry | not-accessible | current | An entry containing management information applicable to a particular interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.1 | ColumnhpnicfEOCUniInPkts | read-only | current | The total number of packets (including bad packets, broadcast packets, and multicast packets) received. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.2 | ColumnhpnicfEOCUniInUPkts | read-only | current | The total number of good packets received that are directed to the unicast address. Note that this does not include multicast and broadcast packets. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.3 | ColumnhpnicfEOCUniInBPkts | read-only | current | The total number of good packets received that are directed to the broadcast address. Note that this does not include multicast packets. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.4 | ColumnhpnicfEOCUniInMPkts | read-only | current | The total number of good packets received that are directed to a multicast address. Note that this number does not include packets directed to the broadcast ad… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.5 | ColumnhpnicfEOCUniInPausePkts | read-only | current | A count of MAC Control packets received on this interface by the pause(flow control) operation. This counter does not increment when the interface is in a half… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.6 | ColumnhpnicfEOCUniInTotalErrors | read-only | current | Total count of the error packets received on this interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.7 | ColumnhpnicfEOCUniInCRCErrs | read-only | current | The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had eit… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.8 | ColumnhpnicfEOCUniInUndersizePkts | read-only | current | The total number of packets received that are less than 64 octets long (excluding framing bits, but including FCS octets) and are otherwise well formed. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.9 | ColumnhpnicfEOCUniInOversizePkts | read-only | current | The total number of packets received that are longer than 1518 octets (excluding framing bits, but including FCS octets) and are otherwise well formed. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.10 | ColumnhpnicfEOCUniInErrorbyOther | read-only | current | The total number of other error packets received on this interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.11 | ColumnhpnicfEOCUniInOctets | read-only | current | The total number of octets received on this interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.12 | ColumnhpnicfEOCUniOutPkts | read-only | current | The total number of packets (including bad packets, broadcast packets, and multicast packets) sent. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.13 | ColumnhpnicfEOCUniOutUPkts | read-only | current | The total number of good packets sent that are directed to the unicast address. Note that this does not include multicast and broadcast packets. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.14 | ColumnhpnicfEOCUniOutBPkts | read-only | current | The total number of good packets sent that are directed to the broadcast address. Note that this does not include multicast packets. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.15 | ColumnhpnicfEOCUniOutMPkts | read-only | current | The total number of good packets sent that are directed to a multicast address. Note that this number does not include packets directed to the broadcast addres… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.16 | ColumnhpnicfEOCUniOutPausePkts | read-only | current | The total number of MAC control packets sent on this interface by the pause operation. This counter does not increment when the interface is in a half-duplex m… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.17 | ColumnhpnicfEOCUniOutTotalErrors | read-only | current | The total number of error packets sent on this interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.18 | ColumnhpnicfEOCUniOutCollisions | read-only | current | The best estimate of the total number of collisions on this Ethernet segment. The value returned will depend on the location of the RMON probe. Section 8.2.1.3… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.19 | ColumnhpnicfEOCUniOutDelayExceedDsds | read-only | current | The number of packets discarded by this port due to excessive transit delay through the bridge. It is incremented by both transparent and source route bridges. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.20 | ColumnhpnicfEOCUniOutErrorbyOther | read-only | current | The total number of other error packets sent on this interface. Other error packets means the error packets out of collision packets and excessive delayed pack… |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.21 | ColumnhpnicfEOCUniOutDroppedFrames | read-only | current | The total number of frames dropped because of buffer failure. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.4.2.1.22 | ColumnhpnicfEOCUniOutOctets | read-only | current | The total number of octets transmitted out of the interface. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5 | NodehpnicfEOCCommonTrap | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0 | NodehpnicfEOCTrapPrefix | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.1 | NotificationhpnicfEOCCnuRegExcessTrap | current | A hpnicfEOCCnuRegExcessTrap notification is sent when the number of registered CNUs exceeds the limit. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.2 | NotificationhpnicfEOCCnuRegExcessRecoverTrap | current | A hpnicfEOCCnuRegExcessRecoverTrap notification is sent when hpnicfEOCCnuRegExcessTrap is detected and then recoverd. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.3 | NotificationhpnicfEOCCnuRegSuccTrap | current | A hpnicfEOCCnuRegSuccTrap notification is sent when a CNU registers successful. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.4 | NotificationhpnicfEOCCnuOffLineTrap | current | A hpnicfEOCCnuOffLineTrap notification is sent when a CNU offline. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.5 | NotificationhpnicfEOCCnuLinkupTrap | current | A hpnicfEOCCnuLinkupTrap notification is sent when a CNU linkup. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.6 | NotificationhpnicfEOCOamDisconnectTrap | current | A hpnicfEOCOamDisconnectionTrap notification is sent when LLID's OAM link is disconnected. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.7 | NotificationhpnicfEOCOamDisconnectRecoverTrap | current | A hpnicfEOCOamDisconnectionRecoverTrap notification is sent when LLID's OAM link is disconnected and then connected. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.8 | NotificationhpnicfEOCBandwidthNotEnoughTrap | current | Bandwidth is not enough, cnu can not bind now. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.9 | NotificationhpnicfEOCCnuAttenuationTrap | current | A hpnicfHPEOCCnuAttenuationTrap notification is sent when a CNU's attenuation is changing. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.10 | NotificationhpnicfEOCCnuRegFailTrap | current | A hpnicfEOCCnuRegFailTrap notification is sent when a CNU registers fail. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.11 | NotificationhpnicfEOCCLTCablePortErrorTrap | current | A hpnicfEOCCLTCablePortErrorTrap notification is sent when the hardware of cable port occurs error or CLT's vlan is configged error. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.12 | NotificationhpnicfEOCCLTCablePortErrReTrap | current | A hpnicfEOCCLTCablePortErrReTrap notification is sent when cable port error and then recovered. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.13 | NotificationhpnicfEOCCnuTxRateDropTrap | current | A hpnicfEOCCnuTxRateDropTrap notification is sent when cable port rate of TX capability drop exceeded threshold. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.14 | NotificationhpnicfEOCCnuTxRateDropRecoverTrap | current | A hpnicfEOCCnuTxRateDropRecoverTrap notification is sent when cable port rate of TX capability recover from the recent rate-drop trap. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.15 | NotificationhpnicfEOCCnuRxRateDropTrap | current | A hpnicfEOCCnuRxRateDropTrap notification is sent when cable port rate of RX capability drop exceeded threshold. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.16 | NotificationhpnicfEOCCnuRxRateDropRecoverTrap | current | A hpnicfEOCCnuRxRateDropRecoverTrap notification is sent when cable port rate of RX capability recover from the recent rate-drop trap. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.17 | NotificationhpnicfEOCCnuFWDownLoadErrTrap | current | A hpnicfEOCCnuFWDownLoadErrTrap notification is sent when CLT can't download CNU firmware from the server successfully. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.18 | NotificationhpnicfEOCCnuFWDownLoadErrReTrap | current | A hpnicfEOCCnuFWDownLoadErrReTrap notification is sent when CLT recover from the download CNU firmware error. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.19 | NotificationhpnicfEOCCnuDeviceTypeErrTrap | current | A hpnicfEOCCnuDeviceTypeErrTrap notification is sent when the online CNU doesn't match the type which user defined earlier. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.20 | NotificationhpnicfEOCCnuDeviceTypeErrReTrap | current | A hpnicfEOCCnuDeviceTypeErrReTrap notification is sent when the online CNU doesn't match the type which user defined earlier and then recover. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.21 | NotificationhpnicfEOCCnuAutoUpdateErrTrap | current | A hpnicfEOCCnuAutoUpdateErrTrap notification is sent when the online CNU doesn't auto update successfully. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.22 | NotificationhpnicfEOCCnuAutoUpdateSuccTrap | current | A hpnicfEOCCnuAutoUpdateSuccTrap notification is sent when the online CNU auto update successfully. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.23 | NotificationhpnicfEOCLoopbackDetectTrap | current | A hpnicfEOCLoopbackDetectTrap notification is sent when the loopback between the ethernet ports of CNU or CLT is found. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.5.0.24 | NotificationhpnicfEOCLoopbackRecoverTrap | current | A hpnicfEOCLoopbackRecoverTrap notification is sent when the loopback between the ethernet ports of CNU or CLT is recover. | |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6 | NodehpnicfEOCComOnLineCnuMan | |||
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.1 | TablehpnicfEOCComCnuTypeTable | not-accessible | current | This table defines the description of cnu typ. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.1.1 | RowhpnicfEOCComCnuTypeEntry | not-accessible | current | The entry of the table hpnicfEOCComCnuTypeTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.1.1.1 | ColumnhpnicfEOCComCnuTypeIdx | not-accessible | current | A unique value for each cnu types. Its value ranges between 1 and the value of cny typess. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.1.1.2 | ColumnhpnicfEOCComCnuDescripton | read-only | current | The description for unique cnu types. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.2 | TablehpnicfEOCComCnuNumTable | not-accessible | current | This table defines the number of cnu registered in variable types of the CLT . |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.2.1 | RowhpnicfEOCComCnuNumEntry | not-accessible | current | The entry of the table hpnicfEOCComCnuNumTable. |
| 1.3.6.1.4.1.11.2.14.11.15.2.83.6.2.1.1 | ColumnhpnicfEOCComCnuNumber | read-only | current | The number of special type of cnu that has been registerd in clt. |