HUAWEI-LINE-COMMON-MIB

126 objects
The MIB is used for defining Huawei's ACCESS management common MIB objects.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.6.158IdentityhwAccessCommonMIBmanagementThe MIB is used for defining Huawei's ACCESS management common MIB objects.
1.3.6.1.4.1.2011.6.158.1NodehwAccessCommonObjectMIB
1.3.6.1.4.1.2011.6.158.1.1NodehwAccessCommonObjects
1.3.6.1.4.1.2011.6.158.1.1.1NodehwAccessCommonControlObjects
1.3.6.1.4.1.2011.6.158.1.1.1.1TablehwOpticsDdmInfoExTablenot-accessiblecurrentTable hwOpticsDdmInfoExTable supports the query of the information about the optical transceiver. The index of this table is ifIndex.
1.3.6.1.4.1.2011.6.158.1.1.1.1.1RowhwOpticsDdmInfoExEntrynot-accessiblecurrentTable hwOpticsDdmInfoExTable supports the query of the information about the optical transceiver. The index of this entry is ifIndex.
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.1ColumnhwOpticsDdmInfoExTemperatureread-onlycurrentTemperature of the optical transceiver. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is dete…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.2ColumnhwOpticsDdmInfoExTemperatureHighAlarmThresholdread-onlycurrentUpper alarm threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.3ColumnhwOpticsDdmInfoExTemperatureLowAlarmThresholdread-onlycurrentLower alarm threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.4ColumnhwOpticsDdmInfoExTemperatureHighWarningThresholdread-onlycurrentUpper warning threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is …
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.5ColumnhwOpticsDdmInfoExTemperatureLowWarningThresholdread-onlycurrentLower warning threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is …
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.6ColumnhwOpticsDdmInfoExSupplyVoltageread-onlycurrentVoltage of the optical transceiver. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.7ColumnhwOpticsDdmInfoExSupplyVoltageHighAlarmThresholdread-onlycurrentUpper alarm threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.8ColumnhwOpticsDdmInfoExSupplyVoltageLowAlarmThresholdread-onlycurrentLower alarm threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.9ColumnhwOpticsDdmInfoExSupplyVoltageHighWarningThresholdread-onlycurrentUpper warning threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.10ColumnhwOpticsDdmInfoExSupplyVoltageLowWarningThresholdread-onlycurrentLower warning threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.11ColumnhwOpticsDdmInfoExTxBiasCurrentread-onlycurrentCurrent of the optical transceiver. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.12ColumnhwOpticsDdmInfoExTxBiasCurrentHighAlarmThresholdread-onlycurrentUpper alarm threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.13ColumnhwOpticsDdmInfoExTxBiasCurrentLowAlarmThresholdread-onlycurrentLower alarm threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.14ColumnhwOpticsDdmInfoExTxBiasCurrentHighWarningThresholdread-onlycurrentUpper warning threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.15ColumnhwOpticsDdmInfoExTxBiasCurrentLowWarningThresholdread-onlycurrentLower warning threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.16ColumnhwOpticsDdmInfoExTxPowerread-onlycurrentTx optical power of the optical transceiver. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.17ColumnhwOpticsDdmInfoExTxPowerHighAlarmThresholdread-onlycurrentUpper alarm threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.18ColumnhwOpticsDdmInfoExTxPowerLowAlarmThresholdread-onlycurrentLower alarm threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.19ColumnhwOpticsDdmInfoExTxPowerHighWarningThresholdread-onlycurrentUpper warning threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.20ColumnhwOpticsDdmInfoExTxPowerLowWarningThresholdread-onlycurrentLower warning threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.21ColumnhwOpticsDdmInfoExRxPowerread-onlycurrentRx optical power of the optical transceiver. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.22ColumnhwOpticsDdmInfoExRxPowerHighAlarmThresholdread-onlycurrentUpper alarm threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.23ColumnhwOpticsDdmInfoExRxPowerLowAlarmThresholdread-onlycurrentLower alarm threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.24ColumnhwOpticsDdmInfoExRxPowerHighWarningThresholdread-onlycurrentUpper warning threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.25ColumnhwOpticsDdmInfoExRxPowerLowWarningThresholdread-onlycurrentLower warning threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.26ColumnhwOpticsDdmInfo10GTxBiasCurrentread-onlycurrentCurrent of the 10g optical transceiver. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.27ColumnhwOpticsDdmInfo10GTxPowerread-onlycurrentTx optical power of the 10g optical transceiver. Unit: 0.01dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.28ColumnhwOpticsDdmInfoExCatvRxPowerHighAlarmThresholdread-onlycurrentUpper AlarmThreshold threshold of the CATV Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.29ColumnhwOpticsDdmInfoExCatvRxPowerLowAlarmThresholdread-onlycurrentLower AlarmThreshold threshold of the CATV Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.30ColumnhwOpticsDdmInfoExModuleTyperead-onlycurrentOptions: 1. gpon(1) - GPON 2. epon(2) - EPON 3. epon10g(3) - 10G EPON 4. gpon10g(4) - 10G GPON 5. wdmpon(5) - WDM PON 6. hybridpon(6) - hybrid PON 7. gponepon(…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.31ColumnhwOpticsDdmInfoExSubTyperead-onlycurrentOptions: 1. classbplus(1) - CLASS B+ 2. classcplus(2) - CLASS C+ 3. classb(3) - CLASS B 4. classcplusplus(4) - CLASS C++ 5. n2a(33) - N2a 6. n2b(34) - N2b 7. n…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.32ColumnhwOpticsDdmInfoExPrecisionread-onlycurrentThis object indicates the precision of optical power. Unit: 0.1dBm Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.33ColumnhwOpticsDdmInfoExEncapsulationTyperead-onlycurrentOptions: 1. sff2x5(1) - SFF 2x5 2. sff2x10(2) - SFF 2x10 3. sfp(3) - SFP 4. xfp(4) - XFP 5. lxfp(5) - LXFP 6. bosaonboard(6) - BOSA ON BOARD 7. unknown(7) - Un…
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.34ColumnhwOpticsDdmInfoExVendorPNread-onlycurrentThis object indicates the part number.
1.3.6.1.4.1.2011.6.158.1.1.1.1.1.35ColumnhwOpticsDdmInfoExUsedTyperead-onlycurrentThis object indicates the application scenario of the optical transceiver. Options: 1. olt(1) - OLT 2. onu(3) - ONU 3. catvtriplex(4) - CATV TriPlex 4. unknown…
1.3.6.1.4.1.2011.6.158.1.1.1.2TablehwXponDeviceOntDdmInfoExTablenot-accessiblecurrentTable hwXponDeviceOntDdmInfoExTable supports the query of the information about the optical transceiver of the ONT port. The index of this table is a combinati…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1RowhwXponDeviceOntDdmInfoExEntrynot-accessiblecurrentTable hwXponDeviceOntDdmInfoExTable supports the query of the information about the optical transceiver of the ONT port. The index of this entry is a combinati…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.1ColumnhwXponOntDdmInfoExOntIndexnot-accessiblecurrentONT ID, range: 0-127
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.2ColumnhwXponOntDdmInfoExTemperatureread-onlycurrentTemperature of the optical transceiver on the ONT. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no informat…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.3ColumnhwXponOntDdmInfoExTemperatureHighAlarmThresholdread-onlycurrentUpper alarm threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.4ColumnhwXponOntDdmInfoExTemperatureLowAlarmThresholdread-onlycurrentLower alarm threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.5ColumnhwXponOntDdmInfoExTemperatureHighWarningThresholdread-onlycurrentUpper warning threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is …
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.6ColumnhwXponOntDdmInfoExTemperatureLowWarningThresholdread-onlycurrentLower warning threshold of the temperature. Unit: 0.000001 C(centigrade) Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is …
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.7ColumnhwXponOntDdmInfoExSupplyVoltageread-onlycurrentVoltage of the optical transceiver on the ONT. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.8ColumnhwXponOntDdmInfoExSupplyVoltageHighAlarmThresholdread-onlycurrentUpper alarm threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.9ColumnhwXponOntDdmInfoExSupplyVoltageLowAlarmThresholdread-onlycurrentLower alarm threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.10ColumnhwXponOntDdmInfoExSupplyVoltageHighWarningThresholdread-onlycurrentUpper warning threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.11ColumnhwXponOntDdmInfoExSupplyVoltageLowWarningThresholdread-onlycurrentLower warning threshold of the voltage. Unit: 0.000001V Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.12ColumnhwXponOntDdmInfoExTxBiasCurrentread-onlycurrentCurrent of the optical transceiver on the ONT. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.13ColumnhwXponOntDdmInfoExTxBiasCurrentHighAlarmThresholdread-onlycurrentUpper alarm threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.14ColumnhwXponOntDdmInfoExTxBiasCurrentLowAlarmThresholdread-onlycurrentLower alarm threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.15ColumnhwXponOntDdmInfoExTxBiasCurrentHighWarningThresholdread-onlycurrentUpper warning threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.16ColumnhwXponOntDdmInfoExTxBiasCurrentLowWarningThresholdread-onlycurrentLower warning threshold of the bias current. Unit: 0.000001A Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.17ColumnhwXponOntDdmInfoExTxPowerread-onlycurrentTx optical power of the optical transceiver on the ONT. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.18ColumnhwXponOntDdmInfoExTxPowerHighAlarmThresholdread-onlycurrentUpper alarm threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.19ColumnhwXponOntDdmInfoExTxPowerLowAlarmThresholdread-onlycurrentLower alarm threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.20ColumnhwXponOntDdmInfoExTxPowerHighWarningThresholdread-onlycurrentUpper warning threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.21ColumnhwXponOntDdmInfoExTxPowerLowWarningThresholdread-onlycurrentLower warning threshold of the Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.22ColumnhwXponOntDdmInfoExRxPowerread-onlycurrentRx optical power of the optical transceiver on the ONT. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.23ColumnhwXponOntDdmInfoExRxPowerHighAlarmThresholdread-onlycurrentUpper alarm threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.24ColumnhwXponOntDdmInfoExRxPowerLowAlarmThresholdread-onlycurrentLower alarm threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.25ColumnhwXponOntDdmInfoExRxPowerHighWarningThresholdread-onlycurrentUpper warning threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.26ColumnhwXponOntDdmInfoExRxPowerLowWarningThresholdread-onlycurrentLower warning threshold of the Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.27ColumnhwXponOntDdmInfoExOltRxOntPowerread-onlycurrentthreshold of the ont Tx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.28ColumnhwXponOntDdmInfoExCatvRxPowerHighAlarmThresholdread-onlycurrentUpper AlarmThreshold threshold of the CATV Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.29ColumnhwXponOntDdmInfoExCatvRxPowerLowAlarmThresholdread-onlycurrentLower AlarmThreshold threshold of the CATV Rx power. Unit: 0.000001dBm Options: 1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is de…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.30ColumnhwXponOntDdmInfoExModuleTyperead-onlycurrentOptions: 1. gpon(1) - GPON 2. epon(2) - EPON 3. epon10g(3) - 10G EPON 4. gpon10g(4) - 10G GPON 5. wdmpon(5) - WDM PON 6. hybridpon(6) - hybrid PON 7. gponepon(…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.31ColumnhwXponOntDdmInfoExSubTyperead-onlycurrentOptions: 1. classbplus(1) - CLASS B+ 2. classcplus(2) - CLASS C+ 3. classb(3) - CLASS B 4. classcplusplus(4) - CLASS C++ 5. n2a(33) - N2a 6. n2b(34) - N2b 7. n…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.32ColumnhwXponOntDdmInfoExPrecisionread-onlycurrentThis object indicates the precision of optical power. Unit: 0.1dBm Options: 1. invalid(-1) - Indicates that the query fails or no information is detected
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.33ColumnhwXponOntDdmInfoExEncapsulationTyperead-onlycurrentOptions: 1. sff2x5(1) - SFF 2x5 2. sff2x10(2) - SFF 2x10 3. sfp(3) - SFP 4. xfp(4) - XFP 5. lxfp(5) - LXFP 6. bosaonboard(6) - BOSA ON BOARD 7. unknown(7) - Un…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.34ColumnhwXponOntDdmInfoExVendorPNread-onlycurrentThis object indicates the part number.
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.35ColumnhwXponOntDdmInfoExUsedTyperead-onlycurrentThis object indicates the application scenario of the optical transceiver. Options: 1. olt(1) - OLT 2. onu(3) - ONU 3. catvtriplex(4) - CATV TriPlex 4. unknown…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.36ColumnhwXponOntDdmInfoExPortIdread-onlycurrentThis object indicates the ID of the ONT PON port where the optical module is located. It is numbered from 0. Options: 1. invalid(-1) - Indicates that the query…
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.37ColumnhwXponOntDdmInfoExVendorNameread-onlycurrentThis object indicates the SFP vendor name (ASCII).
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.38ColumnhwXponOntDdmInfoExVendorRevread-onlycurrentThis object indicates the revision level for part number provided by vendor (ASCII).
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.39ColumnhwXponOntDdmInfoExVendorSNread-onlycurrentThis object indicates the serial number provided by vendor (ASCII).
1.3.6.1.4.1.2011.6.158.1.1.1.2.1.40ColumnhwXponOntDdmInfoExDateCoderead-onlycurrentThis object indicates manufacturing date code of the vendor (ASCII).
1.3.6.1.4.1.2011.6.158.1.1.1.3TablehwXponNniOpticsModuleInfoTablenot-accessiblecurrentThe table supports the query of the information about the optical transceiver of the ONT port. The index of this table is ifIndex.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1RowhwXponNniOpticsModuleInfoEntrynot-accessiblecurrentThe table supports the query of the information about the optical transceiver of the ONT port. The index of this entry is ifIndex.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.1ColumnhwXponNniOpticsModuleInfoVendorNameread-onlycurrentThis object indicates the vendor name.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.2ColumnhwXponNniOpticsModuleInfoVendorRevread-onlycurrentThis object indicates the revision level for part number provided by vendor.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.3ColumnhwXponNniOpticsModuleInfoVendorOUIread-onlycurrentThis object indicates the vendor IEEE company ID.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.4ColumnhwXponNniOpticsModuleInfoVendorPNread-onlycurrentThis object indicates the part number provided by vendor.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.5ColumnhwXponNniOpticsModuleInfoVendorSNread-onlycurrentThis object indicates the serial number provided by vendor.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.6ColumnhwXponNniOpticsModuleInfoDateCoderead-onlycurrentThis object indicates manufacturing date code of the vendor.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.7ColumnhwXponNniOpticsModuleInfoSFF8472Complianceread-onlycurrentIndicates which revision of SFF-8472 the transceiver complies Options: 1. undefined(1) - Not included or undefined 2. includesRev93SFF8472(2) - Includes functi…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.8ColumnhwXponNniOpticsModuleInfoWaveLengthread-onlycurrentThis object indicates the laser wavelength, units of nm.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.9ColumnhwXponNniOpticsModuleInfoIdentifierread-onlycurrentThis object indicates the type of serial transceiver. Options: 1. unknown(1) - Unknown or unspecified 2. gbic(2) - GBIC 3. solderedToMotherboard(3) - Module so…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.10ColumnhwXponNniOpticsModuleInfoExtIDread-onlycurrentThis object indicates the extended identifier of type of serial transceiver. Options: 1. notSpecifiedOrNotCompliant(1) - Not specified or not compliant with a …
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.11ColumnhwXponNniOpticsModuleInfoConnectorread-onlycurrentThis object indicates the code for connector type. Options: 1. unknown(1) - Unknown 2. sc(2) - SC 3. copperConnector1(3) - Fibre Channel Style 1 copper connect…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.12ColumnhwXponNniOpticsModuleInfoEncodingread-onlycurrentThis object indicates the code for serial encoding algorithm. Options: 1. unspecified(1) - Unspecified 2. encodingMethod8B10B(2) - 8B10B 3. encodingMethod4B5B(…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.13ColumnhwXponNniOpticsModuleInfoLength9Micronkmread-onlycurrentThis object indicates the link length supported for 9/125 micron fiber, units of 1000 m.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.14ColumnhwXponNniOpticsModuleInfoLength50Micronread-onlycurrentThis object indicates the link length supported for 50/125 micron fiber, units of 10 m.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.15ColumnhwXponNniOpticsModuleInfoLength62Micron5read-onlycurrentThis object indicates the link length supported for 62.5/125 micron fiber, units of 10 m.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.16ColumnhwXponNniOpticsModuleInfoLengthCopperread-onlycurrentThis object indicates the link length supported for copper, units of meters.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.17ColumnhwXponNniOpticsModuleInfoLengthOm3read-onlycurrentThis object indicates the link length supported for 50/125 micron OM3 fiber, units of 10 m.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.18ColumnhwXponNniOpticsModuleInfoBrMaxread-onlycurrentThis object indicates the upper bit rate margin, units of %.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.19ColumnhwXponNniOpticsModuleInfoBrMinread-onlycurrentThis object indicates the lower bit rate margin, units of %.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.20ColumnhwXponNniOpticsModuleInfoBrNominalread-onlycurrentThis object indicates the nominal bit rate, units of 100 MBits/sec.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.21ColumnhwXponNniOpticsModuleInfoDiagnosticMonitoringTyperead-onlycurrentIndicates which type of diagnostic monitoring is implemented. bit Description of Diagnostic Monitoring Type 7 Reserved 6 Digital diagnostic monitoring 5 Intern…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.22ColumnhwXponNniOpticsModuleInfoOptionsread-onlycurrentIndicates which optional transceiver signals are implemented. bit Description of option 10 Cooled Transceiver Declaration 9 Power Level Declaration 8 Linear Re…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.23ColumnhwXponNniOpticsModuleInfoEnhancedOptionsread-onlycurrentIndicates which optional enhanced features are implemented. bit Description of Enhanced Options 7 Alarm/warning flags 6 TX_DISABLE control and monitoring 5 TX_…
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.24ColumnhwXponNniOpticsModuleInfoCcBaseread-onlycurrentThis object indicates the check code for Base ID Fields.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.25ColumnhwXponNniOpticsModuleInfoCcExtread-onlycurrentThis object indicates the check code for the Extended ID Fields.
1.3.6.1.4.1.2011.6.158.1.1.1.3.1.26ColumnhwXponNniOpticsModuleInfoRateIdentifierread-onlycurrentThis object indicates the code for connector type. Options: 1. undefined1(1) - Not included or undefined 2. sff8079(2) - SFF-8079 4/2/1GRate_Select&AS0/AS1 3. …
1.3.6.1.4.1.2011.6.158.1.1.2NodehwAccessCommonStatisticObjects
1.3.6.1.4.1.2011.6.158.50NodehwLineCommonTrapsVbOids
1.3.6.1.4.1.2011.6.158.50.1ScalarhwPortHostmodeaccessible-for-notifycurrentThe port host mode. Options: 1. geMode(7) - Ge mode 2. adaptMode(27) - Adapt mode 3. gponMode(114) - Gpon mode 4. eponMode(115) - Epon mode
1.3.6.1.4.1.2011.6.158.50.2ScalarhwPortActualmodeaccessible-for-notifycurrentThe port actual mode. Options: 1. geMode(7) - Ge mode 2. adaptMode(27) - Adapt mode 3. gponMode(114) - Gpon mode 4. eponMode(115) - Epon mode 5. unknown(65535)…
1.3.6.1.4.1.2011.6.158.50.3ScalarhwReservedValueaccessible-for-notifycurrentReserved value.
1.3.6.1.4.1.2011.6.158.51NodehwLineCommonTraps
1.3.6.1.4.1.2011.6.158.51.1NodehwLineTraps
1.3.6.1.4.1.2011.6.158.51.1.0NodehwLineTrapsPrefix
1.3.6.1.4.1.2011.6.158.51.1.0.1NotificationhwXponnniPortSwitchTrapcurrentTypeC or TypeD port switch trap. The first ifIndex is the active one after switching over. The second ifIndex is the standby one after switching over.
1.3.6.1.4.1.2011.6.158.51.2NodehwLineAlarmTraps
1.3.6.1.4.1.2011.6.158.51.2.0NodehwLineAlarmTrapsPrefix
1.3.6.1.4.1.2011.6.158.51.2.0.1NotificationhwPortTypeAdaptFaultAlarmTrapcurrentPort type adaptation fault alarm trap. This trap message is generated when the uplink port on the ONU is set to work in adaptive mode, the type of the OLT down…
1.3.6.1.4.1.2011.6.158.51.2.0.2NotificationhwPortTypeAdaptFaultRestoreAlarmTrapcurrentPort type adaptation fault recovery alarm trap. This trap message is generated when the uplink port on the ONU is set to work in adaptive mode, the type of the…
1.3.6.1.4.1.2011.6.158.51.2.0.3NotificationhwPortTypeAdaptSuccessAlarmTrapcurrentPort type adaptation success alarm trap. This trap message is generated when the type of the OLT downlink port transmitting the optical signal changes, the ada…
1.3.6.1.4.1.2011.6.158.51.2.0.4NotificationhwXponnniPortSwitchAlarmTrapcurrentProtection switchover occurs on the PON port and it has no effect on the service. The first hwPortIndex is the source port index, the second hwPortIndex is the…