HUAWEI-SWITCHOVER-MIB

61 objects
This MIB object provides functions of active/standby switchover, data saving and duplication, and query of data synchronization status between the active and standby control boards.
Imported Objects
HUAWEI-DEVICE-MIBhwFrameIndex hwSlotIndex
HUAWEI-MIBhuaweiUtility
SNMPv2-SMI--FROM RFC1155-SMI TimeTicks Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.6.22IdentityhwSwitchOverThis MIB object provides functions of active/standby switchover, data saving and duplication, and query of data synchronization status between the active and s…
1.3.6.1.4.1.2011.6.22.1NodeswitchoverMibObject
1.3.6.1.4.1.2011.6.22.1.1NodehwDataswitchover
1.3.6.1.4.1.2011.6.22.1.1.1ScalarhwQrydatasynconditionread-onlycurrentThe query of the status of data synchronization between the active and standby control boards. Data synchronization between the active and standby control boar…
1.3.6.1.4.1.2011.6.22.1.1.2ScalarhwswitchoverAdminStatusread-writecurrentManual active/standby switchover. Active/standby switchover refers to the process that the standby control board works as the active control board when the act…
1.3.6.1.4.1.2011.6.22.1.1.3ScalarhwDataSYNSWStatusread-writecurrentThe switch of data synchronization. This object is not supported currently. Options: 1. on(1) -The switch of data synchronization is on. 2. off(2) -The switch …
1.3.6.1.4.1.2011.6.22.1.2NodehwDataSave
1.3.6.1.4.1.2011.6.22.1.2.1ScalarhwAutoSaveSwitchread-writecurrentThe switch of automatic data saving. Options: 1. on(1) -indicates that the automatic data saving is enabled. The system saves the data and configuration files …
1.3.6.1.4.1.2011.6.22.1.2.2ScalarhwAutoSaveCycleread-writecurrentThe period of automatic data saving. The period is in the unit of 10 ms, with a value range of 60000-60480000 (10 minutes to one week). If the data saving is e…
1.3.6.1.4.1.2011.6.22.1.2.3ScalarhwImmediateSaveread-writecurrentIt is the object for saving the data and the configuration file. Options: 1. saveDBBDRN(1) -indicates that the data and the configuration file are saved at the…
1.3.6.1.4.1.2011.6.22.1.2.4ScalarhwAutoSaveTimeSwitchread-writecurrentThe switch of automatic data saving at the absolute time. Options: 1. on(1) -indicates that the automatic data saving at the absolute time is enabled. That is,…
1.3.6.1.4.1.2011.6.22.1.2.5ScalarhwAutoSaveTimeread-writecurrentThe time of automatic data saving. This value can be converted into the hexadecimal number 0x00hhmmss (hh representing hour, mm representing minute, and ss rep…
1.3.6.1.4.1.2011.6.22.1.2.6ScalarhwSaveDataread-writecurrentImmediate saving of the database. Only database is saved through the operation on this object. Options: 1. nosavedata(-1) -No database saving is performed in t…
1.3.6.1.4.1.2011.6.22.1.2.7ScalarhwSaveConfigurationread-writecurrentIt is the object for saving the configuration file. Options: 1. saveconfiguration(1) -indicates that only the configuration file is saved, the data is not save…
1.3.6.1.4.1.2011.6.22.1.2.8ScalarhwSaveRequestIDread-writecurrentThe saving of the operation request ID. The request ID is used for identifying each saving operation. It must be unique, and cannot be issued separately. The o…
1.3.6.1.4.1.2011.6.22.1.2.9ScalarhwActiveConfigurationread-writecurrentThe activation of the configuration files. Options: 1. noactiveConfiguration(-1) -indicates that the configuration files are not activated. 2. activeConfigurat…
1.3.6.1.4.1.2011.6.22.1.2.10ScalarhwActiveConfigurationResultread-onlycurrentThe result of Configuration Actived. Options: 1. partialFailure(1) -indicates that activating the configuration files of the active control board fails. 2. suc…
1.3.6.1.4.1.2011.6.22.1.2.11ScalarhwAutoSaveCfgChangedtimerread-writecurrentThe time of saving configuration files automatically. The time is in the unit of 10 ms,with a value range of 12000-8640000 (two minutes to one day). If the val…
1.3.6.1.4.1.2011.6.22.1.2.12ScalarhwAutoSaveTyperead-writecurrentThe type of automatic saving. Options: 1. database(1) -indicates the saving of only the database. 2. configuration(2) -indicates the saving of only the configu…
1.3.6.1.4.1.2011.6.22.1.2.13ScalarhwEraseDataread-writecurrentThe erasing of the database. If the configuration data of the active or standby control board needs to be erased, the database requires to be erased. After the…
1.3.6.1.4.1.2011.6.22.1.3NodehwRollBack
1.3.6.1.4.1.2011.6.22.1.3.1ScalarhwRollBackOperread-writecurrentThis object is used to roll back the system. Options: 1. initial(1) -Indicates the initial value. 2. rollback(2) -Indicates the system is to be rolled back.
1.3.6.1.4.1.2011.6.22.1.4NodehwDuplicate
1.3.6.1.4.1.2011.6.22.1.4.1ScalarhwSynDataAdminStatusread-writecurrentDuplication of the host programs, databases, multi-lingual files, configuration files, and package files from the active control board to the standby control b…
1.3.6.1.4.1.2011.6.22.1.4.2ScalarhwDuplicateProcessread-onlycurrentThe process of duplication. Range: 0-100
1.3.6.1.4.1.2011.6.22.1.4.3ScalarhwCloneRequestIDread-writeobsoleteThe request ID for operation information table. This object is not supported currently.
1.3.6.1.4.1.2011.6.22.1.5NodehwDataChange
1.3.6.1.4.1.2011.6.22.1.5.1ScalarhwSystemDataChangeread-onlycurrentQuerying whether the system configuration (database and configuration files) changes. For the value of this object, 0 indicates that the system configuration d…
1.3.6.1.4.1.2011.6.22.1.5.2ScalarhwSystemDataStateread-onlycurrentQuerying whether the current database is null. A null database refers to the database with no configuration data. Options: 1. blank(1) -indicates that the data…
1.3.6.1.4.1.2011.6.22.1.5.3ScalarhwSystemDataInitStateread-onlycurrentQuerying database state when system init. Options: 1. blank(1) -indicates that the database is null. 2. modified(2) -indicates that the database is not null.
1.3.6.1.4.1.2011.6.22.1.6NodehwConfigurationResumedResult
1.3.6.1.4.1.2011.6.22.1.6.1TablehwConfigurationUnResumedTablenot-accessiblecurrentThis table is used to query information not restored during the system configuration restoration.
1.3.6.1.4.1.2011.6.22.1.6.1.1RowhwConfigurationUnResumedEntrynot-accessiblecurrentThe index of this entry is hwConfigurationUnResumedListIndex.
1.3.6.1.4.1.2011.6.22.1.6.1.1.1ColumnhwConfigurationUnResumedListIndexnot-accessiblecurrentThis is the index of table hwConfigurationUnResumedTable.
1.3.6.1.4.1.2011.6.22.1.6.1.1.2ColumnhwConfigurationUnResumedListread-onlycurrentThis is a list for unresumed configurations, for example: board add 0/1 ADI board add 0/2 FBSDE
1.3.6.1.4.1.2011.6.22.1.6.1.1.3ColumnhwConfigurationUnResumedListIsLastread-onlycurrentIndicates whether the unresumed configuration list is the last one. Options: 1.islast(1)-last. 2.notlast(2)-not last.
1.3.6.1.4.1.2011.6.22.2NodehwSwitchOverTraps
1.3.6.1.4.1.2011.6.22.2.1NodehwSwitchOverTrapsOids
1.3.6.1.4.1.2011.6.22.2.1.1ScalarhwConfigSNaccessible-for-notifycurrentThe count of saving the system configurations.
1.3.6.1.4.1.2011.6.22.2.1.2ScalarhwSynSchedulguageaccessible-for-notifycurrentProgress of the synchronization between the active and standby control boards. Range: 0-100
1.3.6.1.4.1.2011.6.22.2.1.3ScalarhwTrapSaveResultaccessible-for-notifycurrentResult of the data saving. The returned value 0 indicates that the data is saved successfully. The returned value 1 indicates that the data saving fails.
1.3.6.1.4.1.2011.6.22.2.2NodehwSwitchOverCommonTraps
1.3.6.1.4.1.2011.6.22.2.2.0NodehwSwitchOverCommonTrapsPrefix
1.3.6.1.4.1.2011.6.22.2.2.0.1NotificationhwSysCfgChangedTrapcurrentThis trap message is reported when the system database is being saved.
1.3.6.1.4.1.2011.6.22.2.2.0.2NotificationhwSynScheduleTrapcurrentThis trap message, indicating the synchronization progress, is reported during the data synchronization between the active and standby control boards.
1.3.6.1.4.1.2011.6.22.2.2.0.3NotificationhwSaveConfigStartTrapcurrentThis trap is reported when configuration file starts to be saved.
1.3.6.1.4.1.2011.6.22.2.2.0.4NotificationhwSaveConfigCompleteTrapcurrentThis trap is reported when configuration file is saved completely.
1.3.6.1.4.1.2011.6.22.2.3NodehwSwitchOverAlarmTraps
1.3.6.1.4.1.2011.6.22.2.3.0NodehwSwitchOverAlarmTrapsPrefix
1.3.6.1.4.1.2011.6.22.2.3.0.1NotificationhwSwitchoverTrapcurrentThis trap is reported when the switchover occurs between the active and standby boards.
1.3.6.1.4.1.2011.6.22.2.3.0.2NotificationhwBatchBackupStartTrapcurrentThis trap is reported when the system batch hot backup starts.
1.3.6.1.4.1.2011.6.22.2.3.0.3NotificationhwBatchBackupCompleteTrapcurrentThis trap is reported when the system batch hot backup is complete.
1.3.6.1.4.1.2011.6.22.2.3.0.4NotificationhwInUpgradeTrapcurrentThis trap is reported when the system enters the in-service upgrade scenario.
1.3.6.1.4.1.2011.6.22.2.3.0.5NotificationhwSoftVersionInconsistentTrapcurrentThis trap is reported when software versions of active and standby boards are inconsistent.
1.3.6.1.4.1.2011.6.22.2.3.0.6NotificationhwDataChangeDuringSwitchOverTrapcurrentThis trap is reported when Data changes during the system switchover.
1.3.6.1.4.1.2011.6.22.3NodehwSwitchOverControl
1.3.6.1.4.1.2011.6.22.3.1ScalarhwSwitchOverStatusread-writecurrentThe switch of the active/standby switchover. Options: 1. on(1) -indicates that the active/standby switchover is enabled. 2. off(2) -indicates that the active/s…
1.3.6.1.4.1.2011.6.22.3.2ScalarhwSwitchOverPeriodread-writecurrentThe period of the active/standby switchover. Options: 1. day(1) -indicates that the switchover is performed once a day. 2. week(2) -indicates that the switchov…
1.3.6.1.4.1.2011.6.22.3.3ScalarhwSwitchOverInverseDayNoread-writecurrentDays since the periodic switchover has been started. Its value range depends on the value of object hwSwitchOverPeriod. When hwSwitchOverPeriod is set to day(1…
1.3.6.1.4.1.2011.6.22.3.4ScalarhwSwitchOverTimeread-writecurrentTime when switchover will happen. Time is set by a string in the format of hh:mm:ss. The value range of hh is from 00 to 23. The value range of mm is from 00 t…
1.3.6.1.4.1.2011.6.22.3.5ScalarhwAutoSwitchOverStatusread-writecurrentStatus of auto switchover function. If the value of switchover switch hwSwitchOverStatus is off(2), the system cannot perform the active/standby switchover. Op…