MIB Viewer

IEEE8021-CFM-V2-MIB

49 objects
Connectivity Fault Management V2 module. Unless otherwise indicated, the references in this MIB module are to IEEE 802.1Q-2011. Copyright (C) IEEE. This version of this MIB module is part of IEEE802.1Q; see the draft itself for full legal notices.
OIDNameAccessStatusDescription
1.3.111.2.802.1.1.7Identityieee8021CfmV2MibConnectivity Fault Management V2 module. Unless otherwise indicated, the references in this MIB module are to IEEE 802.1Q-2011. Copyright (C) IEEE. This versio…
1.3.111.2.802.1.1.8.1.1.2Tableieee8021CfmStackTablenot-accessiblecurrentThere is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface.
1.3.111.2.802.1.1.8.1.1.2.1Rowieee8021CfmStackEntrynot-accessiblecurrentThe Stack table entry
1.3.111.2.802.1.1.8.1.1.2.1.1Columnieee8021CfmStackifIndexnot-accessiblecurrentThis object represents the Bridge Port or aggregated port on which MEPs or MHFs might be configured. Upon a restart of the system, the system SHALL, if necessa…
1.3.111.2.802.1.1.8.1.1.2.1.2Columnieee8021CfmStackServiceSelectorTypenot-accessiblecurrentType of the Service Selector identifier indicated by ieee8021CfmStackServiceSelectorOrNone. See textual convention IEEE8021ServiceSelectorType for details.
1.3.111.2.802.1.1.8.1.1.2.1.3Columnieee8021CfmStackServiceSelectorOrNonenot-accessiblecurrentService Selector identifier to which the MP is attached, or 0, if none. See textual convention IEEE8021ServiceSelectorValue for details.
1.3.111.2.802.1.1.8.1.1.2.1.4Columnieee8021CfmStackMdLevelnot-accessiblecurrentMD Level of the Maintenance Point.
1.3.111.2.802.1.1.8.1.1.2.1.5Columnieee8021CfmStackDirectionnot-accessiblecurrentDirection in which the MP faces on the Bridge Port
1.3.111.2.802.1.1.8.1.1.2.1.6Columnieee8021CfmStackMdIndexread-onlycurrentThe index of the Maintenance Domain in the ieee8021CfmMdTable to which the MP is associated, or 0, if none.
1.3.111.2.802.1.1.8.1.1.2.1.7Columnieee8021CfmStackMaIndexread-onlycurrentThe index of the MA in the ieee8021CfmMaNetTable and ieee8021CfmMaCompTable to which the MP is associated, or 0, if none.
1.3.111.2.802.1.1.8.1.1.2.1.8Columnieee8021CfmStackMepIdread-onlycurrentIf an MEP is configured, the MEPID, else 0
1.3.111.2.802.1.1.8.1.1.2.1.9Columnieee8021CfmStackMacAddressread-onlycurrentMAC address of the MP.
1.3.111.2.802.1.1.8.1.2.5Tableieee8021CfmDefaultMdTablenot-accessiblecurrentFor each bridge component, the Default MD Level Managed Object controls MHF creation for VIDs that are not attached to a specific Maintenance Association Manag…
1.3.111.2.802.1.1.8.1.2.5.1Rowieee8021CfmDefaultMdEntrynot-accessiblecurrentThe Default MD Level table entry.
1.3.111.2.802.1.1.8.1.2.5.1.1Columnieee8021CfmDefaultMdComponentIdnot-accessiblecurrentThe bridge component within the system to which the information in this ieee8021CfmDefaultMdEntry applies. If the system is not a Bridge, or if only one compon…
1.3.111.2.802.1.1.8.1.2.5.1.2Columnieee8021CfmDefaultMdPrimarySelectorTypenot-accessiblecurrentType of the Primary Service Selector identifier indicated by ieee8021CfmDefaultMdPrimarySelector. See textual convention IEEE8021ServiceSelectorType for detail…
1.3.111.2.802.1.1.8.1.2.5.1.3Columnieee8021CfmDefaultMdPrimarySelectornot-accessiblecurrentPrimary Service Selector identifier of a Service Instance with no MA configured. See IEEE8021ServiceSelectorValue for details.
1.3.111.2.802.1.1.8.1.2.5.1.4Columnieee8021CfmDefaultMdStatusread-onlycurrentState of this Default MD Level table entry. True if there is no entry in the Maintenance Association table defining an MA for the same VLAN ID and MD Level as …
1.3.111.2.802.1.1.8.1.2.5.1.5Columnieee8021CfmDefaultMdLevelread-writecurrentA value indicating the MD Level at which MHFs are to be created, and Sender ID TLV transmission by those MHFs is to be controlled, for the VLAN to which this e…
1.3.111.2.802.1.1.8.1.2.5.1.6Columnieee8021CfmDefaultMdMhfCreationread-writecurrentA value indicating if the Management entity can create MHFs (MIP Half Function) for this VID at this MD Level. If this object has the value defMHFdefer, MHF cr…
1.3.111.2.802.1.1.8.1.2.5.1.7Columnieee8021CfmDefaultMdIdPermissionread-writecurrentEnumerated value indicating what, if anything, is to be included in the Sender ID TLV (21.5.3) transmitted by MHFs created by the Default Maintenance Domain. I…
1.3.111.2.802.1.1.8.1.3.2Tableieee8021CfmVlanTablenot-accessiblecurrentThis table defines the association of VIDs into VLANs. There is an entry in this table, for each component of the bridge, for each VID that is: a) a VID belong…
1.3.111.2.802.1.1.8.1.3.2.1Rowieee8021CfmVlanEntrynot-accessiblecurrentThe VLAN table entry.
1.3.111.2.802.1.1.8.1.3.2.1.1Columnieee8021CfmVlanComponentIdnot-accessiblecurrentThe bridge component within the system to which the information in this ieee8021CfmVlanEntry applies. If the system is not a Bridge, or if only one component i…
1.3.111.2.802.1.1.8.1.3.2.1.3Columnieee8021CfmVlanSelectornot-accessiblecurrentThis is a service ID belonging to a service that is associated with more than one Service Selector identifiers, and this is not the Primary Service ID of the s…
1.3.111.2.802.1.1.8.1.3.2.1.5Columnieee8021CfmVlanPrimarySelectorread-createcurrentThis is the Primary Service selector for a Service that is associated with more than one Service Selector identifiers. This value MUST not equal the value of i…
1.3.111.2.802.1.1.8.1.3.2.1.6Columnieee8021CfmVlanRowStatusread-createcurrentThe status of the row. The writable columns in a row can not be changed if the row is active. All columns MUST have a valid value before a row can be activated.
1.3.111.2.802.1.1.8.1.4.2Tableieee8021CfmConfigErrorListTablenot-accessiblecurrentThe CFM Configuration Error List table provides a list of Interfaces and VIDs that are incorrectly configured.
1.3.111.2.802.1.1.8.1.4.2.1Rowieee8021CfmConfigErrorListEntrynot-accessiblecurrentThe Config Error List Table entry
1.3.111.2.802.1.1.8.1.4.2.1.1Columnieee8021CfmConfigErrorListSelectorTypenot-accessiblecurrentType of the Service Selector identifier indicated by ieee8021CfmConfigErrorListSelector. See textual convention IEEE8021ServiceSelectorType for details.
1.3.111.2.802.1.1.8.1.4.2.1.2Columnieee8021CfmConfigErrorListSelectornot-accessiblecurrentThe Service Selector Identifier of the Service with interfaces in error. See IEEE8021ServiceSelectorValue for details.
1.3.111.2.802.1.1.8.1.4.2.1.3Columnieee8021CfmConfigErrorListIfIndexnot-accessiblecurrentThis object is the IfIndex of the interface. Upon a restart of the system, the system SHALL, if necessary, change the value of this variable so that it indexes…
1.3.111.2.802.1.1.8.1.4.2.1.4Columnieee8021CfmConfigErrorListErrorTyperead-onlycurrentA vector of Boolean error conditions from 22.2.4, any of which may be true: 0) CFMleak; 1) ConflictingVids; 2) ExcessiveLevels; 3) OverlappedLevels.
1.3.111.2.802.1.1.8.1.6.4Tableieee8021CfmMaCompTablenot-accessiblecurrentThe Maintenance Association table. Each row in the table represents an MA. An MA is a set of MEPs, each configured with a single service instance. This is the …
1.3.111.2.802.1.1.8.1.6.4.1Rowieee8021CfmMaCompEntrynot-accessiblecurrentThe MA table entry.
1.3.111.2.802.1.1.8.1.6.4.1.1Columnieee8021CfmMaComponentIdnot-accessiblecurrentThe bridge component within the system to which the information in this ieee8021CfmMaCompEntry applies. If the system is not a Bridge, or if only one component…
1.3.111.2.802.1.1.8.1.6.4.1.2Columnieee8021CfmMaCompPrimarySelectorTyperead-createcurrentType of the Service Selector identifiers indicated by ieee8021CfmMaCompPrimarySelectorOrNone. If the service instance is defined by more than one Service Selec…
1.3.111.2.802.1.1.8.1.6.4.1.3Columnieee8021CfmMaCompPrimarySelectorOrNoneread-createcurrentService Selector identifier to which the MP is attached, or 0, if none. If the MA is associated with more than one Service Selectors Identifiers, the ieee8021C…
1.3.111.2.802.1.1.8.1.6.4.1.4Columnieee8021CfmMaCompMhfCreationread-createcurrentIndicates if the Management entity can create MHFs (MIP Half Function) for this MA.
1.3.111.2.802.1.1.8.1.6.4.1.5Columnieee8021CfmMaCompIdPermissionread-createcurrentEnumerated value indicating what, if anything, is to be included in the Sender ID TLV (21.5.3) transmitted by MPs configured in this MA.
1.3.111.2.802.1.1.8.1.6.4.1.6Columnieee8021CfmMaCompNumberOfVidsread-createcurrentThe number of VIDs associated with the MA.
1.3.111.2.802.1.1.8.1.6.4.1.7Columnieee8021CfmMaCompRowStatusread-createcurrentThe status of the row. The writable columns in a row can not be changed if the row is active. All columns MUST have a valid value before a row can be activated.
1.3.111.2.802.1.1.8.2.1.2Complianceieee8021CfmComplianceV2not-accessiblecurrentThe compliance statement for support of the CFM MIB module.
1.3.111.2.802.1.1.8.2.1.3Compliancedot1agCfmWithPbbTeCompliancenot-accessiblecurrentThe compliance statement for support of the CFM MIB for systems that support PBB-TE.
1.3.111.2.802.1.1.8.2.2.12Groupieee8021CfmStackGroupcurrentObjects for the Stack group.
1.3.111.2.802.1.1.8.2.2.13Groupieee8021CfmMaGroupcurrentObjects for the MA group.
1.3.111.2.802.1.1.8.2.2.14Groupieee8021CfmDefaultMdGroupcurrentObjects for the Default MD Level group.
1.3.111.2.802.1.1.8.2.2.15Groupieee8021CfmVlanIdGroupcurrentObjects for the VLAN ID group.
1.3.111.2.802.1.1.8.2.2.16Groupieee8021CfmConfigErrorListGroupcurrentObjects for the CFM Configuration Error List Group.