This is the MRV LX HDAM Alarm MIB module.
Imported Objects
MRV-IR-SYSTEM-MIBTrapSeverity
SNMPv2-SMICounter32 enterprises MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.33NodemrvBpd
1.3.6.1.4.1.33.100NodemrvLx
1.3.6.1.4.1.33.100.4IdentityirHdamMibThis is the MRV LX HDAM Alarm MIB module.
1.3.6.1.4.1.33.100.4.1NodeirHdam
1.3.6.1.4.1.33.100.4.1.1TableirHdamUnitTablenot-accessiblecurrentA list of hdam unit entries.
1.3.6.1.4.1.33.100.4.1.1.1RowirHdamUnitEntrynot-accessiblecurrentAn hdam unit entry.
1.3.6.1.4.1.33.100.4.1.1.1.1ColumnirHdamUnitPortIndexread-onlycurrentThe port index to which this hdam unit is connected.
1.3.6.1.4.1.33.100.4.1.1.1.2ColumnirHdamFwVersionread-onlycurrentThe HDAM unit firmware version string.
1.3.6.1.4.1.33.100.4.1.1.1.3ColumnirHdamConnectStatusread-onlycurrentThe HDAM unit connection status.
1.3.6.1.4.1.33.100.4.1.1.1.4ColumnirHdamPowerTyperead-onlycurrentThe type of power used by the hdam device.
1.3.6.1.4.1.33.100.4.1.1.1.5ColumnirHdamActionread-writecurrentThis object is used to perform an action on the HDAM unit. A read of this object always returns the value other(1). Setting this object to reset(2) causes the …
1.3.6.1.4.1.33.100.4.1.2TableirHdamModuleTablenot-accessiblecurrentA list of hdam module entries.
1.3.6.1.4.1.33.100.4.1.2.1RowirHdamModuleEntrynot-accessiblecurrentAn hdam module entry.
1.3.6.1.4.1.33.100.4.1.2.1.1ColumnirHdamPortIndexread-onlycurrentThe port index to which this hdam unit is connected.
1.3.6.1.4.1.33.100.4.1.2.1.2ColumnirHdamSlotIndexread-onlycurrentThe slot index for this module entry.
1.3.6.1.4.1.33.100.4.1.2.1.3ColumnirHdamModuleTyperead-onlycurrentThe type of module in the slot.
1.3.6.1.4.1.33.100.4.1.3TableirHdamPowerSupplyTablenot-accessiblecurrentA list of hdam power supply entries.
1.3.6.1.4.1.33.100.4.1.3.1RowirHdamPowerSupplyEntrynot-accessiblecurrentAn hdam power supply entry.
1.3.6.1.4.1.33.100.4.1.3.1.1ColumnirHdamPowerPortIndexread-onlycurrentThe index of the port to which the hdam unit is attached.
1.3.6.1.4.1.33.100.4.1.3.1.2ColumnirHdamPowerIndexread-onlycurrentThe index of the hdam power unit.
1.3.6.1.4.1.33.100.4.1.3.1.3ColumnirHdamPowerUnitPresentread-onlycurrentThis indicates if the power unit is present or not.
1.3.6.1.4.1.33.100.4.1.3.1.4ColumnirHdamPowerInputStatusread-onlycurrentThis indicates if the power unit is plugged into a power source.
1.3.6.1.4.1.33.100.4.1.3.1.5ColumnirHdamPowerOutputStatusread-onlycurrentThis indicates the status of the internal power feed to the device components.
1.3.6.1.4.1.33.100.4.1.3.1.6ColumnirHdamPowerStatusread-onlycurrentThe overall status of the power unit.
1.3.6.1.4.1.33.100.4.2NodeirHdamAlarm
1.3.6.1.4.1.33.100.4.2.1TableirAlarmConfigTablenot-accessiblecurrentA list of alarm config entries.
1.3.6.1.4.1.33.100.4.2.1.1RowirAlarmConfigEntrynot-accessiblecurrentAn hdam alarm config entry.
1.3.6.1.4.1.33.100.4.2.1.1.1ColumnirAlarmPortIndexread-onlycurrentThe port index on which the alarm unit is attached.
1.3.6.1.4.1.33.100.4.2.1.1.2ColumnirAlarmSlotIndexread-onlycurrentThe slot in the alarm unit which identifies this module.
1.3.6.1.4.1.33.100.4.2.1.1.3ColumnirAlarmPointIndexread-onlycurrentAn integer which uniquely identifies an alarm on this module.
1.3.6.1.4.1.33.100.4.2.1.1.4ColumnirAlarmNameread-writecurrentThe name assigned to the alarm.
1.3.6.1.4.1.33.100.4.2.1.1.5ColumnirAlarmContactStateread-onlycurrentThe current state of the alarm contacts.
1.3.6.1.4.1.33.100.4.2.1.1.6ColumnirAlarmContactFaultStateread-writecurrentThe contact state (open or closed) which indicates the fault condition. If the value of this object and irAlarmContactState is the same, then the alarm has bee…
1.3.6.1.4.1.33.100.4.2.1.1.7ColumnirAlarmDebounceIntervalread-writecurrentThe number of seconds the alarm must be in the fault state before it is considered valid.
1.3.6.1.4.1.33.100.4.2.1.1.8ColumnirAlarmAudibleStatusread-writecurrentThis indicates whether the audible alarm on the unit will sound when this alarm is generated.
1.3.6.1.4.1.33.100.4.2.1.1.9ColumnirAlarmTrapStatusread-writecurrentThis indicates whether an snmp trap will be generated when this alarm is generated.
1.3.6.1.4.1.33.100.4.2.1.1.10ColumnirAlarmTrapSeverityread-writecurrentThe trap severity assigned to this alarm. This value will be sent when an alarm fires and an snmp trap is generated.
1.3.6.1.4.1.33.100.4.2.1.1.11ColumnirAlarmCountread-onlycurrentThe number of times the alarm has been generated since the unit was started.
1.3.6.1.4.1.33.100.4.2.1.1.12ColumnirAlarmTimestampread-onlycurrentA timestamp string indicating the time the last alarm was generated. A null string indicates that the alarm has not been generated.
1.3.6.1.4.1.33.100.4.2.1.1.13ColumnirAlarmDescriptionread-writecurrentA user configurable alarm description string.
1.3.6.1.4.1.33.100.4.3NodeirHdamControl
1.3.6.1.4.1.33.100.4.3.1TableirControlConfigTablenot-accessiblecurrentA list of control config entries.
1.3.6.1.4.1.33.100.4.3.1.1RowirControlConfigEntrynot-accessiblecurrentA control config entry.
1.3.6.1.4.1.33.100.4.3.1.1.1ColumnirControlPortIndexread-onlycurrentThe port index on which the control unit is attached.
1.3.6.1.4.1.33.100.4.3.1.1.2ColumnirControlSlotIndexread-onlycurrentThe slot in the control unit which identifies this module.
1.3.6.1.4.1.33.100.4.3.1.1.3ColumnirControlPointIndexread-onlycurrentAn integer which uniquely identifies a control on this module.
1.3.6.1.4.1.33.100.4.3.1.1.4ColumnirControlNameread-writecurrentThe name assigned to the control.
1.3.6.1.4.1.33.100.4.3.1.1.5ColumnirControlStateread-writecurrentThe current value of the control state.
1.3.6.1.4.1.33.100.4.3.1.1.6ColumnirControlActiveStateread-writecurrentThe value of the control state that activates the attached device.
1.3.6.1.4.1.33.100.4.3.1.1.7ColumnirControlDescriptionread-writecurrentA user configurable control description string.
1.3.6.1.4.1.33.100.4.4NodeirHdamAnalog
1.3.6.1.4.1.33.100.4.4.1TableirAnalogConfigTablenot-accessiblecurrentA list of analog loop config entries.
1.3.6.1.4.1.33.100.4.4.1.1RowirAnalogConfigEntrynot-accessiblecurrentAn analog loop config entry.
1.3.6.1.4.1.33.100.4.4.1.1.1ColumnirAnalogPortIndexread-onlycurrentThe port index on which the analog unit is attached.
1.3.6.1.4.1.33.100.4.4.1.1.2ColumnirAnalogSlotIndexread-onlycurrentThe slot in the analog unit which identifies this module.
1.3.6.1.4.1.33.100.4.4.1.1.3ColumnirAnalogPointIndexread-onlycurrentAn integer which uniquely identifies an analog point on this module.
1.3.6.1.4.1.33.100.4.4.1.1.4ColumnirAnalogNameread-writecurrentThe name assigned to the analog.
1.3.6.1.4.1.33.100.4.4.1.1.5ColumnirAnalogDescriptionread-writecurrentA user configurable analog description string.
1.3.6.1.4.1.33.100.4.4.1.1.6ColumnirAnalogStatusread-writecurrentThe status of the analog point.
1.3.6.1.4.1.33.100.4.4.1.1.7ColumnirAnalogValueread-onlycurrentThe current analog sensor reading in milliAmps.
1.3.6.1.4.1.33.100.4.4.1.1.8ColumnirAnalogCalValueread-onlycurrentThe current analog sensor calibrated value.
1.3.6.1.4.1.33.100.4.4.1.1.9ColumnirAnalogCalMinValueread-writecurrentThe calibration value assigned to the minimum sensor reading.
1.3.6.1.4.1.33.100.4.4.1.1.10ColumnirAnalogCalMaxValueread-writecurrentThe calibration value assigned to the maximum analog sensor reading.
1.3.6.1.4.1.33.100.4.4.1.1.11ColumnirAnalogCalMarginread-writecurrentThe calibration margin value. This will be added to the calibrated analog sensor value.
1.3.6.1.4.1.33.100.4.4.1.1.12ColumnirAnalogCalUnitsread-writecurrentA user defined string describing the calibrated units for the analog sensor.
1.3.6.1.4.1.33.100.4.4.1.1.13ColumnirAnalogThresholdHighread-writecurrentThe analog sensor high threshold value. A value of -0 indicates threshold is not configured.
1.3.6.1.4.1.33.100.4.4.1.1.14ColumnirAnalogThresholdLowread-writecurrentThe analog sensor low threshold value. A value of -0 indicates threshold is not configured.
1.3.6.1.4.1.33.100.4.4.1.1.15ColumnirAnalogThresholdSeverityread-writecurrentThe severity value of the analog sensor assigned to the low threshold. This value will be sent in the threshold trap.
1.3.6.1.4.1.33.100.4.4.1.1.16ColumnirAnalogThresholdHysteresisread-writecurrentAfter crossing a threshold, the delta by which the caliberated value must drop within the normal range before the alarm condition is cleared (i.e. a cleared al…
1.3.6.1.4.1.33.100.4.4.1.1.17ColumnirAnalogThresholdHighAlarmCountread-onlycurrentThe number of times the analog sensor high threshold has been crossed since the unit was started.
1.3.6.1.4.1.33.100.4.4.1.1.18ColumnirAnalogThresholdLowAlarmCountread-onlycurrentThe number of times the analog sensor low threshold has been crossed since the unit was started.