NBS-EUSM-MIB
186 objects
MIB for representing NBS Eusm information
Imported Objects
| NBS-CMMC-MIB | nbsCmmcPortEntry nbsCmmcSlotEntry |
| NBS-MIB | nbs |
| SNMPv2-SMI | Counter32 Counter64 Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString RowStatus StorageType |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.629.202 | IdentitynbsEusmMib | MIB for representing NBS Eusm information | ||
| 1.3.6.1.4.1.629.202.1 | IdentitynbsEusmSlotGrp | current | Stage-II Slot context features for EUSM boards | |
| 1.3.6.1.4.1.629.202.1.1 | TablenbsEusmSlotTable | not-accessible | current | Contains a description of slot context features applicable for the whole module. There is going to be one row for each slot. All the scalar type objects applic… |
| 1.3.6.1.4.1.629.202.1.1.1 | RownbsEusmSlotEntry | not-accessible | current | Contains a description of slot context features applicable for the whole module. There is going to be one row for each slot. All the scalar type objects applic… |
| 1.3.6.1.4.1.629.202.1.1.1.1 | ColumnnbsEusmSlotSupportsEusm | read-only | current | Is EUSM config and status supported for this slot? |
| 1.3.6.1.4.1.629.202.1.1.1.2 | ColumnnbsEusmSlotAccControlActionUntag | read-write | current | permit(2) or deny(3) works on all untagged frames |
| 1.3.6.1.4.1.629.202.1.1.1.3 | ColumnnbsEusmSlotAccControlActionTag | read-write | current | denyAll(2) filters all tagged frames denyVlan(3) and permitVlan(4) work on the specified list permitAll(5) negates access control of tagged frames |
| 1.3.6.1.4.1.629.202.1.1.1.4 | ColumnnbsEusmSlotAccControlVidList | read-write | current | List of VLAN in a free format, for example 10-12 15 23-43 1000-1050 specifies 3 different ranges of vlan ids and one isolated vlan id |
| 1.3.6.1.4.1.629.202.1.1.1.5 | ColumnnbsEusmSlotLinkAggrAdmin | read-write | current | Depending on the link status of the trunk ports the Link Aggregation operational status may be different, this is why it calls for both Admin and Oper objects |
| 1.3.6.1.4.1.629.202.1.1.1.6 | ColumnnbsEusmSlotLinkAggrOper | read-only | current | |
| 1.3.6.1.4.1.629.202.1.1.1.7 | ColumnnbsEusmSlotStormControlBroadcast | read-write | current | User-specified maximum allowed Broadcast frames, in units of 1000 frames/second. The value zero (0) indicates this feature is disabled, so no cap will be enfor… |
| 1.3.6.1.4.1.629.202.1.1.1.8 | ColumnnbsEusmSlotStormControlMulticast | read-write | current | User-specified maximum allowed Multicast frames, in units of 1000 frames/second. The value zero (0) indicates this feature is disabled, so no cap will be enfor… |
| 1.3.6.1.4.1.629.202.1.1.1.9 | ColumnnbsEusmSlotStormControlUnicast | read-write | current | User-specified maximum allowed Unicast frames, in units of 1000 frames/second. The value zero (0) indicates this feature is disabled, so no cap will be enforce… |
| 1.3.6.1.4.1.629.202.1.1.1.10 | ColumnnbsEusmSlotStormBurstSize | read-write | deprecated | **** DEPRECATED **** |
| 1.3.6.1.4.1.629.202.1.1.1.11 | ColumnnbsEusmSlotCoSMode | read-write | current | If the user selects bothTagDscp(4), and a packet arrives with both DSCP and a Vlan tag, the DSCP priority system will take precedence. tagOnly(3) will use Laye… |
| 1.3.6.1.4.1.629.202.1.1.1.12 | ColumnnbsEusmSlotDscpRemark | read-write | current | The EUSM can be set to mark egress packets with a new DSCP. The user can set to remark egress DSCP in one of the following modes: AF or CS Remarking only appli… |
| 1.3.6.1.4.1.629.202.1.1.1.13 | ColumnnbsEusmSlotDscpEgressMode | read-write | current | The user can set to egress remark DSCP in one of the following modes: a) Map CoS class to AF CPs (call it AF-mode) 0: AF12 1: AF22 2: AF32 3: AF42 b) Map CoS c… |
| 1.3.6.1.4.1.629.202.1.1.1.14 | ColumnnbsEusmSlotDscpIngressEf | read-write | current | One of the five ingress options EF,AF,CS,ZERO and OTHER |
| 1.3.6.1.4.1.629.202.1.1.1.15 | ColumnnbsEusmSlotDscpIngressAf | read-write | current | One of the five ingress options EF,AF,CS,ZERO and OTHER |
| 1.3.6.1.4.1.629.202.1.1.1.16 | ColumnnbsEusmSlotDscpIngressCs | read-write | current | One of the five ingress options EF,AF,CS,ZERO and OTHER |
| 1.3.6.1.4.1.629.202.1.1.1.17 | ColumnnbsEusmSlotDscpIngressZeroDscp | read-write | current | One of the five ingress options EF,AF,CS,ZERO and OTHER |
| 1.3.6.1.4.1.629.202.1.1.1.18 | ColumnnbsEusmSlotDscpIngressAllOther | read-write | current | One of the five ingress options EF,AF,CS,ZERO and OTHER |
| 1.3.6.1.4.1.629.202.1.1.1.19 | ColumnnbsEusmSlotIometrix | read-write | current | Controls whether or not the EUSM should enable Iometrix Level 1 cNode agent behavior |
| 1.3.6.1.4.1.629.202.1.1.1.20 | ColumnnbsEusmSlotManagementVid | read-write | current | VLAN Id reserved for EUSM management activities. |
| 1.3.6.1.4.1.629.202.1.1.1.21 | ColumnnbsEusmSlotUserPortIRAdmin | read-write | current | Unit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to represent 1 Terabit communication. This applies to user ingress … |
| 1.3.6.1.4.1.629.202.1.1.1.22 | ColumnnbsEusmSlotUserPortIROper | read-only | current | Unit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to represent 1 Terabit communication. This is the actual value appl… |
| 1.3.6.1.4.1.629.202.1.1.1.23 | ColumnnbsEusmSlotMaxFlowCfgSize | read-only | current | Maximum number of entries in the FlowCfg table. This may vary from slot to slot if different versions of EUSM software support different table sizes. |
| 1.3.6.1.4.1.629.202.1.1.1.24 | ColumnnbsEusmSlotMaxVlanTranSize | read-only | current | Maximum number of entries in the VLAN Translation table. This may vary from slot to slot if different versions of EUSM software support different table sizes. |
| 1.3.6.1.4.1.629.202.1.1.1.25 | ColumnnbsEusmSlotMaxDscpMapSize | read-only | current | Maximum number of entries in the DSCP to SLC Priority Map table. This may vary from slot to slot if different versions of EUSM software support different table… |
| 1.3.6.1.4.1.629.202.1.1.1.26 | ColumnnbsEusmSlotMaxCosPrioSize | read-only | current | Maximum number of entries in the VLAN CoS to SLC Priority table. This may vary from slot to slot if different versions of EUSM software support different table… |
| 1.3.6.1.4.1.629.202.1.2 | TablenbsEusmFlowCfgTable | not-accessible | current | A table that describes the Vlan Flow Rate Limits At the moment there is a limit of 32 entries for this table |
| 1.3.6.1.4.1.629.202.1.2.1 | RownbsEusmFlowCfgEntry | not-accessible | current | Contains a description of a particular Vlan Flow Rate Limit information |
| 1.3.6.1.4.1.629.202.1.2.1.1 | ColumnnbsEusmFlowCfgChassis | read-only | current | The index of the table to refer to Chassis |
| 1.3.6.1.4.1.629.202.1.2.1.2 | ColumnnbsEusmFlowCfgSlot | read-only | current | The index of the table to refer to Slot of this EUSM |
| 1.3.6.1.4.1.629.202.1.2.1.3 | ColumnnbsEusmFlowCfgVid | read-only | current | The Vid part of the index. |
| 1.3.6.1.4.1.629.202.1.2.1.4 | ColumnnbsEusmFlowCfgPriority | read-only | current | Priority part of the VLAN as index. 0(Zero) is don't care and the real priority starts 1 based. |
| 1.3.6.1.4.1.629.202.1.2.1.5 | ColumnnbsEusmFlowCfgRowStatus | read-create | current | This table RowStatus object to create, modify and delete the rows |
| 1.3.6.1.4.1.629.202.1.2.1.6 | ColumnnbsEusmFlowCfgStorageType | read-create | current | This table StorageType |
| 1.3.6.1.4.1.629.202.1.2.1.7 | ColumnnbsEusmFlowCfgIRAdmin | read-create | current | Information Rate (IR) specified for the Vid and priority combo. Unit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to … |
| 1.3.6.1.4.1.629.202.1.2.1.8 | ColumnnbsEusmFlowCfgIROper | read-only | current | Information Rate (IR) that is actually applied to the flow. Unit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to repr… |
| 1.3.6.1.4.1.629.202.1.2.1.9 | ColumnnbsEusmFlowCfgClearCounter | read-create | current | To clear the counters for selected row |
| 1.3.6.1.4.1.629.202.1.3 | TablenbsEusmFlowStatusTable | not-accessible | current | A table that describes the Vlan Flow Rate Limits At the moment there is a limit of 32 entries for this table. |
| 1.3.6.1.4.1.629.202.1.3.1 | RownbsEusmFlowStatusEntry | not-accessible | current | Contains status part of the FlowCfgTable |
| 1.3.6.1.4.1.629.202.1.3.1.1 | ColumnnbsEusmFlowStatusRxFrames | read-only | current | Received Frames counted |
| 1.3.6.1.4.1.629.202.1.3.1.2 | ColumnnbsEusmFlowStatusRxOctets | read-only | current | Received Octets counted |
| 1.3.6.1.4.1.629.202.1.4 | TablenbsEusmVidMapTable | not-accessible | current | A table that describes the Vlan Translation table At the moment there is a limit of 3 or 7 entries for this table |
| 1.3.6.1.4.1.629.202.1.4.1 | RownbsEusmVidMapEntry | not-accessible | current | Contains a description of a particular Vlan Translation table feature |
| 1.3.6.1.4.1.629.202.1.4.1.1 | ColumnnbsEusmVidMapChassis | read-only | current | The index of the table to refer to Chassis |
| 1.3.6.1.4.1.629.202.1.4.1.2 | ColumnnbsEusmVidMapSlot | read-only | current | The index of the table to refer to Slot of this EUSM |
| 1.3.6.1.4.1.629.202.1.4.1.3 | ColumnnbsEusmVidMapFromVid | read-only | current | The vlanTranslation index. |
| 1.3.6.1.4.1.629.202.1.4.1.4 | ColumnnbsEusmVidMapToVid | read-create | current | The vlanTranslation index. |
| 1.3.6.1.4.1.629.202.1.4.1.5 | ColumnnbsEusmVidMapRowStatus | read-create | current | This table RowStatus object to create, modify and delete the rows |
| 1.3.6.1.4.1.629.202.1.4.1.6 | ColumnnbsEusmVidMapStorageType | read-create | current | This table StorageType |
| 1.3.6.1.4.1.629.202.1.5 | TablenbsEusmCoSDscpMapTable | not-accessible | current | Only 7 possible rows in this table.It is possible to make this table without the RowStatus object as there are not going to be variable number of rows in this … |
| 1.3.6.1.4.1.629.202.1.5.1 | RownbsEusmCoSDscpMapEntry | not-accessible | current | Ingress Tag prio is mapped to egress SL class queue or priority |
| 1.3.6.1.4.1.629.202.1.5.1.1 | ColumnnbsEusmCoSDscpMapChassis | read-only | current | The index of the table to refer to Chassis |
| 1.3.6.1.4.1.629.202.1.5.1.2 | ColumnnbsEusmCoSDscpMapSlot | read-only | current | The index of the table to refer to Slot of this EUSM |
| 1.3.6.1.4.1.629.202.1.5.1.3 | ColumnnbsEusmCoSDscpMapDscp | read-only | current | DSCP range is 0..63 and since it is an index we make it 1..64 as the 1 based range |
| 1.3.6.1.4.1.629.202.1.5.1.4 | ColumnnbsEusmCoSDscpMapSlcPrio | read-create | current | Service Level Class Priority has 4 queues. Each ingress packet is assigned a Diffserv Service Level Class as part of the ingress traffic process. A packet can … |
| 1.3.6.1.4.1.629.202.1.5.1.5 | ColumnnbsEusmCoSDscpMapRowStatus | read-create | current | This table RowStatus object to create, modify and delete the rows |
| 1.3.6.1.4.1.629.202.1.5.1.6 | ColumnnbsEusmCoSDscpMapStorageType | read-create | current | This table StorageType |
| 1.3.6.1.4.1.629.202.1.6 | TablenbsEusmCoSTagPrioMapTable | not-accessible | current | Only 8 rows in this table. It is a fixed size table because rows for all values of the table index Priority object must be defined in the configured device. |
| 1.3.6.1.4.1.629.202.1.6.1 | RownbsEusmCoSTagPrioMapEntry | not-accessible | current | Ingress Tag priority is mapped to egress Service Level class queue or priority. |
| 1.3.6.1.4.1.629.202.1.6.1.1 | ColumnnbsEusmCoSTagPrioMapChassis | read-only | current | The index of the table to refer to Chassis |
| 1.3.6.1.4.1.629.202.1.6.1.2 | ColumnnbsEusmCoSTagPrioMapSlot | read-only | current | The index of the table to refer to Slot of this EUSM |
| 1.3.6.1.4.1.629.202.1.6.1.3 | ColumnnbsEusmCoSTagPrioMapPriority | read-only | current | Tag priority range is 0..7. |
| 1.3.6.1.4.1.629.202.1.6.1.4 | ColumnnbsEusmCoSTagPrioMapSlcPrio | read-create | current | Service Level Class Priority has 4 queues. Each ingress packet is assigned a Diffserv Service Level Class as part of the ingress traffic process. A packet can … |
| 1.3.6.1.4.1.629.202.2 | IdentitynbsEusmPortGrp | current | Stage-II Port context featurea for EUSM boards | |
| 1.3.6.1.4.1.629.202.2.1 | TablenbsEusmPortTable | not-accessible | current | Contains a description of Port context features applicable There is going to be one row for each port. All the scalar type objects applicable at the port conte… |
| 1.3.6.1.4.1.629.202.2.1.1 | RownbsEusmPortEntry | not-accessible | current | Contains a description of slot context features applicable for the whole module. There is going to be one row for each slot. All the scalar type objects applic… |
| 1.3.6.1.4.1.629.202.2.1.1.1 | ColumnnbsEusmPortSupportsEusm | read-only | current | Is EUSM config and status supported for this slot? |
| 1.3.6.1.4.1.629.202.2.1.1.2 | ColumnnbsEusmPortSmartLoopbackAction | read-write | current | |
| 1.3.6.1.4.1.629.202.2.1.1.3 | ColumnnbsEusmPortSmartLoopbackSwap | read-write | current | |
| 1.3.6.1.4.1.629.202.2.1.1.4 | ColumnnbsEusmPortSmartLoopbackMac | read-write | current | |
| 1.3.6.1.4.1.629.202.2.1.1.5 | ColumnnbsEusmPortSmartLoopbackVid | read-write | current | |
| 1.3.6.1.4.1.629.202.2.1.1.6 | ColumnnbsEusmPortVlanTagAction | read-write | current | add(2) need two more arguments s-vlanId and s-vlan-priority strip(3)and ignore(4) does not need any argument |
| 1.3.6.1.4.1.629.202.2.1.1.7 | ColumnnbsEusmPortVlanTagVid | read-write | current | need to be specified when VlanTagAction is add(2) |
| 1.3.6.1.4.1.629.202.2.1.1.8 | ColumnnbsEusmPortVlanTagPriority | read-write | current | need to be specified when VlanTagAction is add(2) |
| 1.3.6.1.4.1.629.202.3 | IdentitynbsEusmTestGrp | current | Testing category of features for EUSM boards. The example items that may go here are the smart loopback traffic generation, loss/gain analysis, performance mon… | |
| 1.3.6.1.4.1.629.202.3.1 | TablenbsEusmTgaTable | not-accessible | current | Contains a description of Test context features applicable. There is going to be one row for each port. |
| 1.3.6.1.4.1.629.202.3.1.1 | RownbsEusmTgaEntry | not-accessible | current | Contains a description of slot context features applicable for the whole module. There is going to be one row for each port. |
| 1.3.6.1.4.1.629.202.3.1.1.1 | ColumnnbsEusmTgaDa | read-write | current | Destination Address - MAC address |
| 1.3.6.1.4.1.629.202.3.1.1.2 | ColumnnbsEusmTgaDaType | read-write | current | Different options to specify the Destination Address |
| 1.3.6.1.4.1.629.202.3.1.1.3 | ColumnnbsEusmTgaSa | read-write | current | Source Address - MAC address |
| 1.3.6.1.4.1.629.202.3.1.1.4 | ColumnnbsEusmTgaSaType | read-write | current | Different options to specify the Source Address |
| 1.3.6.1.4.1.629.202.3.1.1.5 | ColumnnbsEusmTgaTag | read-write | current | VLAN tag or e-type plus initial data If VLAN tagging is not specified (i.e. Tag does not begin as '8100h', then the first two bytes of Tag define the frame typ… |
| 1.3.6.1.4.1.629.202.3.1.1.6 | ColumnnbsEusmTgaTagType | read-write | current | Different options to specify the Tag |
| 1.3.6.1.4.1.629.202.3.1.1.7 | ColumnnbsEusmTgaPattern | read-write | current | The two Pattern bytes are replicated as needed to fill-out the frame to the specified size |
| 1.3.6.1.4.1.629.202.3.1.1.8 | ColumnnbsEusmTgaPatternType | read-write | current | Different options to specify the Source Address |
| 1.3.6.1.4.1.629.202.3.1.1.9 | ColumnnbsEusmTgaFrameSize | read-write | current | Frame Size range from 64 to 9600 |
| 1.3.6.1.4.1.629.202.3.1.1.10 | ColumnnbsEusmTgaFrameSizeType | read-write | current | Different options to specify the Frame Size |
| 1.3.6.1.4.1.629.202.3.1.1.11 | ColumnnbsEusmTgaFrameCount | read-write | current | |
| 1.3.6.1.4.1.629.202.3.1.1.12 | ColumnnbsEusmTgaFrameCountType | read-write | current | Different options to specify the Frame Size |
| 1.3.6.1.4.1.629.202.3.1.1.13 | ColumnnbsEusmTgaInterPacketGap | read-write | current | Rate Control - only option is fixed. Default is 1249928. This sets an approx rate of 100/10/1 fps at 1000/100/10 Mbps. Number of bytes between frames. Controls… |
| 1.3.6.1.4.1.629.202.3.1.1.14 | ColumnnbsEusmTgaAction | read-write | current | Different actions to activate the traffic generation. There are three frame generation activities: specify, start, and stop. Specifying and actually starting t… |
| 1.3.6.1.4.1.629.202.3.2 | TablenbsEusmCableTestTable | not-accessible | current | Cable testing feature |
| 1.3.6.1.4.1.629.202.3.2.1 | RownbsEusmCableTestEntry | not-accessible | current | Cable testing feature |
| 1.3.6.1.4.1.629.202.3.2.1.1 | ColumnnbsEusmCableTestStatus | read-write | current | To initiate and get the status of the cable test feature. It is applicable only to copper ports. In the future we may have multiple copper ports. A GET on this… |
| 1.3.6.1.4.1.629.202.3.2.1.2 | ColumnnbsEusmCableTestResult | read-only | current | This string will give out the result of the cable test done with a time stamp that gives the indication as to when the CableTest was initiated. This also gives… |
| 1.3.6.1.4.1.629.202.3.3 | TablenbsEusmLgaTable | not-accessible | current | Contains a description of Traffic discrepancy counters. |
| 1.3.6.1.4.1.629.202.3.3.1 | RownbsEusmLgaEntry | not-accessible | current | Discrepancy entry |
| 1.3.6.1.4.1.629.202.3.3.1.1 | ColumnnbsEusmLgaRdAllFrames | read-only | current | The count of all frames (good+bad) lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.2 | ColumnnbsEusmLgaRducFrames | read-only | current | The count of good unicast frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.3 | ColumnnbsEusmLgaRdmcFrames | read-only | current | The count of good multicast frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.4 | ColumnnbsEusmLgaRdbcFrames | read-only | current | The count of good broadcast frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.5 | ColumnnbsEusmLgaRdSize64 | read-only | current | The count of all 64 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.6 | ColumnnbsEusmLgaRdSizeMax127 | read-only | current | The count of all 65-127 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.7 | ColumnnbsEusmLgaRdSizeMax255 | read-only | current | The count of all 128-255 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.8 | ColumnnbsEusmLgaRdSizeMax511 | read-only | current | The count of all 256-511 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.9 | ColumnnbsEusmLgaRdSizeMax1023 | read-only | current | The count of all 512-1023 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.10 | ColumnnbsEusmLgaRdSizeMax1518 | read-only | current | The count of all 1024-1518 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.11 | ColumnnbsEusmLgaRdSizeMax2047 | read-only | current | The count of all 1519-2047 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.12 | ColumnnbsEusmLgaRdSizeOvr2047 | read-only | current | The count of all 2048-plus byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.13 | ColumnnbsEusmLgaRdFrameDivisor | read-only | current | The divisor to calculate frame loss/gain ratios for the most recent interval. |
| 1.3.6.1.4.1.629.202.3.3.1.14 | ColumnnbsEusmLgaRdAllOctets | read-only | current | The count of all frame octets lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.15 | ColumnnbsEusmLgaRdOctetDivisor | read-only | current | The divisor to calculate octet loss/gain ratios for the most recent interval. |
| 1.3.6.1.4.1.629.202.3.3.1.16 | ColumnnbsEusmLgaRdTimeSpan | read-only | current | The time span (tenths of a sec) for the most recent interval. |
| 1.3.6.1.4.1.629.202.3.3.1.17 | ColumnnbsEusmLgaAdAllFrames | read-only | current | The accumulated count of all frames (good+bad) lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.18 | ColumnnbsEusmLgaAducFrames | read-only | current | The accumulated count of good unicast frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.19 | ColumnnbsEusmLgaAdmcFrames | read-only | current | The accumulated count of good multicast frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.20 | ColumnnbsEusmLgaAdbcFrames | read-only | current | The accumulated count of good broadcast frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.21 | ColumnnbsEusmLgaAdSize64 | read-only | current | The accumulated count of all 64 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.22 | ColumnnbsEusmLgaAdSizeMax127 | read-only | current | The accumulated count of all 65-127 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.23 | ColumnnbsEusmLgaAdSizeMax255 | read-only | current | The accumulated count of all 128-255 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.24 | ColumnnbsEusmLgaAdSizeMax511 | read-only | current | The accumulated count of all 256-511 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.25 | ColumnnbsEusmLgaAdSizeMax1023 | read-only | current | The accumulated count of all 512-1023 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.26 | ColumnnbsEusmLgaAdSizeMax1518 | read-only | current | The accumulated count of all 1024-1518 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.27 | ColumnnbsEusmLgaAdSizeMax2047 | read-only | current | The accumulated count of all 1519-2047 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.28 | ColumnnbsEusmLgaAdSizeOvr2047 | read-only | current | The accumulated count of all 2048-plus byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.29 | ColumnnbsEusmLgaAdFrameDivisor | read-only | current | The divisor to calculate frame loss/gain ratios over all intervals. |
| 1.3.6.1.4.1.629.202.3.3.1.30 | ColumnnbsEusmLgaAdAllOctets | read-only | current | The accumulated count of all frame octets lost/gained (-/+) over all intervals. Not supported value: 0x80000000 |
| 1.3.6.1.4.1.629.202.3.3.1.31 | ColumnnbsEusmLgaAdOctetDivisor | read-only | current | The divisor to calculate octet loss/gain ratios over all intervals. |
| 1.3.6.1.4.1.629.202.3.3.1.32 | ColumnnbsEusmLgaAdTimeSpan | read-only | current | The accumulated time span (tenths of a sec) for all intervals. |
| 1.3.6.1.4.1.629.202.3.3.1.33 | ColumnnbsEusmSlotLgaInterval | read-write | current | Traffic Analysis (loss/gain) sampling time interval (sec). Practical range allowed is 10 seconds to 1 day. |
| 1.3.6.1.4.1.629.202.3.3.1.34 | ColumnnbsEusmSlotLgaAction | read-write | current | Traffic Analysis (loss/gain) activity status. |
| 1.3.6.1.4.1.629.202.3.4 | TablenbsEusmPmTable | not-accessible | current | Contains a description of Traffic discrepancy counters. |
| 1.3.6.1.4.1.629.202.3.4.1 | RownbsEusmPmEntry | not-accessible | current | Performance Monitoring entry |
| 1.3.6.1.4.1.629.202.3.4.1.1 | ColumnnbsEusmPmAvgAllSizes | read-only | current | The average transit time (nanosec) for monitored frames. |
| 1.3.6.1.4.1.629.202.3.4.1.2 | ColumnnbsEusmPmAvg64 | read-only | current | The average transit time (nanosec) for monitored 64 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.3 | ColumnnbsEusmPmAvg127 | read-only | current | The average transit time (nanosec) for monitored 65-127 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.4 | ColumnnbsEusmPmAvg255 | read-only | current | The average transit time (nanosec) for monitored 128-255 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.5 | ColumnnbsEusmPmAvg511 | read-only | current | The average transit time (nanosec) for monitored 256-511 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.6 | ColumnnbsEusmPmAvg1023 | read-only | current | The average transit time (nanosec) for monitored 512-1023 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.7 | ColumnnbsEusmPmAvg1518 | read-only | current | The average transit time (nanosec) for monitored 1024-1518 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.8 | ColumnnbsEusmPmAvg2047 | read-only | current | The average transit time (nanosec) for monitored 1519-2047 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.9 | ColumnnbsEusmPmAvgOvr2047 | read-only | current | The average transit time (nanosec) for monitored 2048-plus byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.10 | ColumnnbsEusmPmMinAllSizes | read-only | current | The minimum transit time (nanosec) for monitored frames. |
| 1.3.6.1.4.1.629.202.3.4.1.11 | ColumnnbsEusmPmMin64 | read-only | current | The minimum transit time (nanosec) for monitored 64 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.12 | ColumnnbsEusmPmMin127 | read-only | current | The minimum transit time (nanosec) for monitored 65-127 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.13 | ColumnnbsEusmPmMin255 | read-only | current | The minimum transit time (nanosec) for monitored 128-255 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.14 | ColumnnbsEusmPmMin511 | read-only | current | The minimum transit time (nanosec) for monitored 256-511 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.15 | ColumnnbsEusmPmMin1023 | read-only | current | The minimum transit time (nanosec) for monitored 512-1023 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.16 | ColumnnbsEusmPmMin1518 | read-only | current | The minimum transit time (nanosec) for monitored 1024-1518 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.17 | ColumnnbsEusmPmMin2047 | read-only | current | The minimum transit time (nanosec) for monitored 1519-2047 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.18 | ColumnnbsEusmPmMinOvr2047 | read-only | current | The minimum transit time (nanosec) for monitored 2048-plus byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.19 | ColumnnbsEusmPmMaxAllSizes | read-only | current | The maximum transit time (nanosec) for monitored frames. |
| 1.3.6.1.4.1.629.202.3.4.1.20 | ColumnnbsEusmPmMax64 | read-only | current | The maximum transit time (nanosec) for monitored 64 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.21 | ColumnnbsEusmPmMax127 | read-only | current | The maximum transit time (nanosec) for monitored 65-127 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.22 | ColumnnbsEusmPmMax255 | read-only | current | The maximum transit time (nanosec) for monitored 128-255 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.23 | ColumnnbsEusmPmMax511 | read-only | current | The maximum transit time (nanosec) for monitored 256-511 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.24 | ColumnnbsEusmPmMax1023 | read-only | current | The maximum transit time (nanosec) for monitored 512-1023 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.25 | ColumnnbsEusmPmMax1518 | read-only | current | The maximum transit time (nanosec) for monitored 1024-1518 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.26 | ColumnnbsEusmPmMax2047 | read-only | current | The maximum transit time (nanosec) for monitored 1519-2047 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.27 | ColumnnbsEusmPmMaxOvr2047 | read-only | current | The maximum transit time (nanosec) for monitored 2048-plus byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.28 | ColumnnbsEusmPmFramesAllSizes | read-only | current | The count of all monitored frames. |
| 1.3.6.1.4.1.629.202.3.4.1.29 | ColumnnbsEusmPmFrames64 | read-only | current | The count of all monitored 64 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.30 | ColumnnbsEusmPmFrames127 | read-only | current | The count of all monitored 65-127 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.31 | ColumnnbsEusmPmFrames255 | read-only | current | The count of all monitored 128-255 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.32 | ColumnnbsEusmPmFrames511 | read-only | current | The count of all monitored 256-511 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.33 | ColumnnbsEusmPmFrames1023 | read-only | current | The count of all monitored 512-1023 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.34 | ColumnnbsEusmPmFrames1518 | read-only | current | The count of all monitored 1024-1518 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.35 | ColumnnbsEusmPmFrames2047 | read-only | current | The count of all monitored 1519-2047 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.36 | ColumnnbsEusmPmFramesOvr2047 | read-only | current | The count of all monitored 2048-plus byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.37 | ColumnnbsEusmPmOctetsAllSizes | read-only | current | The count of octets in all monitored frames. |
| 1.3.6.1.4.1.629.202.3.4.1.38 | ColumnnbsEusmPmOctets64 | read-only | current | The count of octets in all monitored 64 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.39 | ColumnnbsEusmPmOctets127 | read-only | current | The count of octets in all monitored 65-127 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.40 | ColumnnbsEusmPmOctets255 | read-only | current | The count of octets in all monitored 128-255 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.41 | ColumnnbsEusmPmOctets511 | read-only | current | The count of octets in all monitored 256-511 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.42 | ColumnnbsEusmPmOctets1023 | read-only | current | The count of octets in all monitored 512-1023 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.43 | ColumnnbsEusmPmOctets1518 | read-only | current | The count of octets in all monitored 1024-1518 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.44 | ColumnnbsEusmPmOctets2047 | read-only | current | The count of octets in all monitored 1519-2047 byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.45 | ColumnnbsEusmPmOctetsOvr2047 | read-only | current | The count of octets in all monitored 2048-plus byte frames. |
| 1.3.6.1.4.1.629.202.3.4.1.46 | ColumnnbsEusmSlotPmInterval | read-write | current | Performance Monitoring time duration (sec). Practical range allowed is 1 minute to 1 week. |
| 1.3.6.1.4.1.629.202.3.4.1.47 | ColumnnbsEusmSlotPmSelector | read-write | current | Performance Monitoring traffic direction selector. coToCpe(2) measures from CO's active trunk port to CPE's active trunk port. cpeToCo(3) measures from CPE's a… |
| 1.3.6.1.4.1.629.202.3.4.1.48 | ColumnnbsEusmSlotPmAction | read-write | current | Traffic Analysis (performance monitoring) activity status. |
| 1.3.6.1.4.1.629.202.3.4.1.49 | ColumnnbsEusmSlotPmCapabilities | read-only | current | This bitmask indicates which performance monitoring selectors this slot can support. This object is mandatory for all slots in systems where the nbsEusmSlotPmS… |