MIB Viewer

NBS-EUSM-MIB

186 objects
MIB for representing NBS Eusm information
OIDNameAccessStatusDescription
1.3.6.1.4.1.629.202IdentitynbsEusmMibMIB for representing NBS Eusm information
1.3.6.1.4.1.629.202.1IdentitynbsEusmSlotGrpcurrentStage-II Slot context features for EUSM boards
1.3.6.1.4.1.629.202.1.1TablenbsEusmSlotTablenot-accessiblecurrentContains a description of slot context features applicable for the whole module. There is going to be one row for each slot. All the scalar type objects applic…
1.3.6.1.4.1.629.202.1.1.1RownbsEusmSlotEntrynot-accessiblecurrentContains a description of slot context features applicable for the whole module. There is going to be one row for each slot. All the scalar type objects applic…
1.3.6.1.4.1.629.202.1.1.1.1ColumnnbsEusmSlotSupportsEusmread-onlycurrentIs EUSM config and status supported for this slot?
1.3.6.1.4.1.629.202.1.1.1.2ColumnnbsEusmSlotAccControlActionUntagread-writecurrentpermit(2) or deny(3) works on all untagged frames
1.3.6.1.4.1.629.202.1.1.1.3ColumnnbsEusmSlotAccControlActionTagread-writecurrentdenyAll(2) filters all tagged frames denyVlan(3) and permitVlan(4) work on the specified list permitAll(5) negates access control of tagged frames
1.3.6.1.4.1.629.202.1.1.1.4ColumnnbsEusmSlotAccControlVidListread-writecurrentList of VLAN in a free format, for example 10-12 15 23-43 1000-1050 specifies 3 different ranges of vlan ids and one isolated vlan id
1.3.6.1.4.1.629.202.1.1.1.5ColumnnbsEusmSlotLinkAggrAdminread-writecurrentDepending on the link status of the trunk ports the Link Aggregation operational status may be different, this is why it calls for both Admin and Oper objects
1.3.6.1.4.1.629.202.1.1.1.6ColumnnbsEusmSlotLinkAggrOperread-onlycurrent
1.3.6.1.4.1.629.202.1.1.1.7ColumnnbsEusmSlotStormControlBroadcastread-writecurrentUser-specified maximum allowed Broadcast frames, in units of 1000 frames/second. The value zero (0) indicates this feature is disabled, so no cap will be enfor…
1.3.6.1.4.1.629.202.1.1.1.8ColumnnbsEusmSlotStormControlMulticastread-writecurrentUser-specified maximum allowed Multicast frames, in units of 1000 frames/second. The value zero (0) indicates this feature is disabled, so no cap will be enfor…
1.3.6.1.4.1.629.202.1.1.1.9ColumnnbsEusmSlotStormControlUnicastread-writecurrentUser-specified maximum allowed Unicast frames, in units of 1000 frames/second. The value zero (0) indicates this feature is disabled, so no cap will be enforce…
1.3.6.1.4.1.629.202.1.1.1.10ColumnnbsEusmSlotStormBurstSizeread-writedeprecated**** DEPRECATED ****
1.3.6.1.4.1.629.202.1.1.1.11ColumnnbsEusmSlotCoSModeread-writecurrentIf the user selects bothTagDscp(4), and a packet arrives with both DSCP and a Vlan tag, the DSCP priority system will take precedence. tagOnly(3) will use Laye…
1.3.6.1.4.1.629.202.1.1.1.12ColumnnbsEusmSlotDscpRemarkread-writecurrentThe EUSM can be set to mark egress packets with a new DSCP. The user can set to remark egress DSCP in one of the following modes: AF or CS Remarking only appli…
1.3.6.1.4.1.629.202.1.1.1.13ColumnnbsEusmSlotDscpEgressModeread-writecurrentThe user can set to egress remark DSCP in one of the following modes: a) Map CoS class to AF CPs (call it AF-mode) 0: AF12 1: AF22 2: AF32 3: AF42 b) Map CoS c…
1.3.6.1.4.1.629.202.1.1.1.14ColumnnbsEusmSlotDscpIngressEfread-writecurrentOne of the five ingress options EF,AF,CS,ZERO and OTHER
1.3.6.1.4.1.629.202.1.1.1.15ColumnnbsEusmSlotDscpIngressAfread-writecurrentOne of the five ingress options EF,AF,CS,ZERO and OTHER
1.3.6.1.4.1.629.202.1.1.1.16ColumnnbsEusmSlotDscpIngressCsread-writecurrentOne of the five ingress options EF,AF,CS,ZERO and OTHER
1.3.6.1.4.1.629.202.1.1.1.17ColumnnbsEusmSlotDscpIngressZeroDscpread-writecurrentOne of the five ingress options EF,AF,CS,ZERO and OTHER
1.3.6.1.4.1.629.202.1.1.1.18ColumnnbsEusmSlotDscpIngressAllOtherread-writecurrentOne of the five ingress options EF,AF,CS,ZERO and OTHER
1.3.6.1.4.1.629.202.1.1.1.19ColumnnbsEusmSlotIometrixread-writecurrentControls whether or not the EUSM should enable Iometrix Level 1 cNode agent behavior
1.3.6.1.4.1.629.202.1.1.1.20ColumnnbsEusmSlotManagementVidread-writecurrentVLAN Id reserved for EUSM management activities.
1.3.6.1.4.1.629.202.1.1.1.21ColumnnbsEusmSlotUserPortIRAdminread-writecurrentUnit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to represent 1 Terabit communication. This applies to user ingress …
1.3.6.1.4.1.629.202.1.1.1.22ColumnnbsEusmSlotUserPortIROperread-onlycurrentUnit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to represent 1 Terabit communication. This is the actual value appl…
1.3.6.1.4.1.629.202.1.1.1.23ColumnnbsEusmSlotMaxFlowCfgSizeread-onlycurrentMaximum number of entries in the FlowCfg table. This may vary from slot to slot if different versions of EUSM software support different table sizes.
1.3.6.1.4.1.629.202.1.1.1.24ColumnnbsEusmSlotMaxVlanTranSizeread-onlycurrentMaximum number of entries in the VLAN Translation table. This may vary from slot to slot if different versions of EUSM software support different table sizes.
1.3.6.1.4.1.629.202.1.1.1.25ColumnnbsEusmSlotMaxDscpMapSizeread-onlycurrentMaximum number of entries in the DSCP to SLC Priority Map table. This may vary from slot to slot if different versions of EUSM software support different table…
1.3.6.1.4.1.629.202.1.1.1.26ColumnnbsEusmSlotMaxCosPrioSizeread-onlycurrentMaximum number of entries in the VLAN CoS to SLC Priority table. This may vary from slot to slot if different versions of EUSM software support different table…
1.3.6.1.4.1.629.202.1.2TablenbsEusmFlowCfgTablenot-accessiblecurrentA table that describes the Vlan Flow Rate Limits At the moment there is a limit of 32 entries for this table
1.3.6.1.4.1.629.202.1.2.1RownbsEusmFlowCfgEntrynot-accessiblecurrentContains a description of a particular Vlan Flow Rate Limit information
1.3.6.1.4.1.629.202.1.2.1.1ColumnnbsEusmFlowCfgChassisread-onlycurrentThe index of the table to refer to Chassis
1.3.6.1.4.1.629.202.1.2.1.2ColumnnbsEusmFlowCfgSlotread-onlycurrentThe index of the table to refer to Slot of this EUSM
1.3.6.1.4.1.629.202.1.2.1.3ColumnnbsEusmFlowCfgVidread-onlycurrentThe Vid part of the index.
1.3.6.1.4.1.629.202.1.2.1.4ColumnnbsEusmFlowCfgPriorityread-onlycurrentPriority part of the VLAN as index. 0(Zero) is don't care and the real priority starts 1 based.
1.3.6.1.4.1.629.202.1.2.1.5ColumnnbsEusmFlowCfgRowStatusread-createcurrentThis table RowStatus object to create, modify and delete the rows
1.3.6.1.4.1.629.202.1.2.1.6ColumnnbsEusmFlowCfgStorageTyperead-createcurrentThis table StorageType
1.3.6.1.4.1.629.202.1.2.1.7ColumnnbsEusmFlowCfgIRAdminread-createcurrentInformation Rate (IR) specified for the Vid and priority combo. Unit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to …
1.3.6.1.4.1.629.202.1.2.1.8ColumnnbsEusmFlowCfgIROperread-onlycurrentInformation Rate (IR) that is actually applied to the flow. Unit is kilobits per second. Max possible value is 4,294,967,295 which is large enough even to repr…
1.3.6.1.4.1.629.202.1.2.1.9ColumnnbsEusmFlowCfgClearCounterread-createcurrentTo clear the counters for selected row
1.3.6.1.4.1.629.202.1.3TablenbsEusmFlowStatusTablenot-accessiblecurrentA table that describes the Vlan Flow Rate Limits At the moment there is a limit of 32 entries for this table.
1.3.6.1.4.1.629.202.1.3.1RownbsEusmFlowStatusEntrynot-accessiblecurrentContains status part of the FlowCfgTable
1.3.6.1.4.1.629.202.1.3.1.1ColumnnbsEusmFlowStatusRxFramesread-onlycurrentReceived Frames counted
1.3.6.1.4.1.629.202.1.3.1.2ColumnnbsEusmFlowStatusRxOctetsread-onlycurrentReceived Octets counted
1.3.6.1.4.1.629.202.1.4TablenbsEusmVidMapTablenot-accessiblecurrentA table that describes the Vlan Translation table At the moment there is a limit of 3 or 7 entries for this table
1.3.6.1.4.1.629.202.1.4.1RownbsEusmVidMapEntrynot-accessiblecurrentContains a description of a particular Vlan Translation table feature
1.3.6.1.4.1.629.202.1.4.1.1ColumnnbsEusmVidMapChassisread-onlycurrentThe index of the table to refer to Chassis
1.3.6.1.4.1.629.202.1.4.1.2ColumnnbsEusmVidMapSlotread-onlycurrentThe index of the table to refer to Slot of this EUSM
1.3.6.1.4.1.629.202.1.4.1.3ColumnnbsEusmVidMapFromVidread-onlycurrentThe vlanTranslation index.
1.3.6.1.4.1.629.202.1.4.1.4ColumnnbsEusmVidMapToVidread-createcurrentThe vlanTranslation index.
1.3.6.1.4.1.629.202.1.4.1.5ColumnnbsEusmVidMapRowStatusread-createcurrentThis table RowStatus object to create, modify and delete the rows
1.3.6.1.4.1.629.202.1.4.1.6ColumnnbsEusmVidMapStorageTyperead-createcurrentThis table StorageType
1.3.6.1.4.1.629.202.1.5TablenbsEusmCoSDscpMapTablenot-accessiblecurrentOnly 7 possible rows in this table.It is possible to make this table without the RowStatus object as there are not going to be variable number of rows in this …
1.3.6.1.4.1.629.202.1.5.1RownbsEusmCoSDscpMapEntrynot-accessiblecurrentIngress Tag prio is mapped to egress SL class queue or priority
1.3.6.1.4.1.629.202.1.5.1.1ColumnnbsEusmCoSDscpMapChassisread-onlycurrentThe index of the table to refer to Chassis
1.3.6.1.4.1.629.202.1.5.1.2ColumnnbsEusmCoSDscpMapSlotread-onlycurrentThe index of the table to refer to Slot of this EUSM
1.3.6.1.4.1.629.202.1.5.1.3ColumnnbsEusmCoSDscpMapDscpread-onlycurrentDSCP range is 0..63 and since it is an index we make it 1..64 as the 1 based range
1.3.6.1.4.1.629.202.1.5.1.4ColumnnbsEusmCoSDscpMapSlcPrioread-createcurrentService Level Class Priority has 4 queues. Each ingress packet is assigned a Diffserv Service Level Class as part of the ingress traffic process. A packet can …
1.3.6.1.4.1.629.202.1.5.1.5ColumnnbsEusmCoSDscpMapRowStatusread-createcurrentThis table RowStatus object to create, modify and delete the rows
1.3.6.1.4.1.629.202.1.5.1.6ColumnnbsEusmCoSDscpMapStorageTyperead-createcurrentThis table StorageType
1.3.6.1.4.1.629.202.1.6TablenbsEusmCoSTagPrioMapTablenot-accessiblecurrentOnly 8 rows in this table. It is a fixed size table because rows for all values of the table index Priority object must be defined in the configured device.
1.3.6.1.4.1.629.202.1.6.1RownbsEusmCoSTagPrioMapEntrynot-accessiblecurrentIngress Tag priority is mapped to egress Service Level class queue or priority.
1.3.6.1.4.1.629.202.1.6.1.1ColumnnbsEusmCoSTagPrioMapChassisread-onlycurrentThe index of the table to refer to Chassis
1.3.6.1.4.1.629.202.1.6.1.2ColumnnbsEusmCoSTagPrioMapSlotread-onlycurrentThe index of the table to refer to Slot of this EUSM
1.3.6.1.4.1.629.202.1.6.1.3ColumnnbsEusmCoSTagPrioMapPriorityread-onlycurrentTag priority range is 0..7.
1.3.6.1.4.1.629.202.1.6.1.4ColumnnbsEusmCoSTagPrioMapSlcPrioread-createcurrentService Level Class Priority has 4 queues. Each ingress packet is assigned a Diffserv Service Level Class as part of the ingress traffic process. A packet can …
1.3.6.1.4.1.629.202.2IdentitynbsEusmPortGrpcurrentStage-II Port context featurea for EUSM boards
1.3.6.1.4.1.629.202.2.1TablenbsEusmPortTablenot-accessiblecurrentContains a description of Port context features applicable There is going to be one row for each port. All the scalar type objects applicable at the port conte…
1.3.6.1.4.1.629.202.2.1.1RownbsEusmPortEntrynot-accessiblecurrentContains a description of slot context features applicable for the whole module. There is going to be one row for each slot. All the scalar type objects applic…
1.3.6.1.4.1.629.202.2.1.1.1ColumnnbsEusmPortSupportsEusmread-onlycurrentIs EUSM config and status supported for this slot?
1.3.6.1.4.1.629.202.2.1.1.2ColumnnbsEusmPortSmartLoopbackActionread-writecurrent
1.3.6.1.4.1.629.202.2.1.1.3ColumnnbsEusmPortSmartLoopbackSwapread-writecurrent
1.3.6.1.4.1.629.202.2.1.1.4ColumnnbsEusmPortSmartLoopbackMacread-writecurrent
1.3.6.1.4.1.629.202.2.1.1.5ColumnnbsEusmPortSmartLoopbackVidread-writecurrent
1.3.6.1.4.1.629.202.2.1.1.6ColumnnbsEusmPortVlanTagActionread-writecurrentadd(2) need two more arguments s-vlanId and s-vlan-priority strip(3)and ignore(4) does not need any argument
1.3.6.1.4.1.629.202.2.1.1.7ColumnnbsEusmPortVlanTagVidread-writecurrentneed to be specified when VlanTagAction is add(2)
1.3.6.1.4.1.629.202.2.1.1.8ColumnnbsEusmPortVlanTagPriorityread-writecurrentneed to be specified when VlanTagAction is add(2)
1.3.6.1.4.1.629.202.3IdentitynbsEusmTestGrpcurrentTesting category of features for EUSM boards. The example items that may go here are the smart loopback traffic generation, loss/gain analysis, performance mon…
1.3.6.1.4.1.629.202.3.1TablenbsEusmTgaTablenot-accessiblecurrentContains a description of Test context features applicable. There is going to be one row for each port.
1.3.6.1.4.1.629.202.3.1.1RownbsEusmTgaEntrynot-accessiblecurrentContains a description of slot context features applicable for the whole module. There is going to be one row for each port.
1.3.6.1.4.1.629.202.3.1.1.1ColumnnbsEusmTgaDaread-writecurrentDestination Address - MAC address
1.3.6.1.4.1.629.202.3.1.1.2ColumnnbsEusmTgaDaTyperead-writecurrentDifferent options to specify the Destination Address
1.3.6.1.4.1.629.202.3.1.1.3ColumnnbsEusmTgaSaread-writecurrentSource Address - MAC address
1.3.6.1.4.1.629.202.3.1.1.4ColumnnbsEusmTgaSaTyperead-writecurrentDifferent options to specify the Source Address
1.3.6.1.4.1.629.202.3.1.1.5ColumnnbsEusmTgaTagread-writecurrentVLAN tag or e-type plus initial data If VLAN tagging is not specified (i.e. Tag does not begin as '8100h', then the first two bytes of Tag define the frame typ…
1.3.6.1.4.1.629.202.3.1.1.6ColumnnbsEusmTgaTagTyperead-writecurrentDifferent options to specify the Tag
1.3.6.1.4.1.629.202.3.1.1.7ColumnnbsEusmTgaPatternread-writecurrentThe two Pattern bytes are replicated as needed to fill-out the frame to the specified size
1.3.6.1.4.1.629.202.3.1.1.8ColumnnbsEusmTgaPatternTyperead-writecurrentDifferent options to specify the Source Address
1.3.6.1.4.1.629.202.3.1.1.9ColumnnbsEusmTgaFrameSizeread-writecurrentFrame Size range from 64 to 9600
1.3.6.1.4.1.629.202.3.1.1.10ColumnnbsEusmTgaFrameSizeTyperead-writecurrentDifferent options to specify the Frame Size
1.3.6.1.4.1.629.202.3.1.1.11ColumnnbsEusmTgaFrameCountread-writecurrent
1.3.6.1.4.1.629.202.3.1.1.12ColumnnbsEusmTgaFrameCountTyperead-writecurrentDifferent options to specify the Frame Size
1.3.6.1.4.1.629.202.3.1.1.13ColumnnbsEusmTgaInterPacketGapread-writecurrentRate Control - only option is fixed. Default is 1249928. This sets an approx rate of 100/10/1 fps at 1000/100/10 Mbps. Number of bytes between frames. Controls…
1.3.6.1.4.1.629.202.3.1.1.14ColumnnbsEusmTgaActionread-writecurrentDifferent actions to activate the traffic generation. There are three frame generation activities: specify, start, and stop. Specifying and actually starting t…
1.3.6.1.4.1.629.202.3.2TablenbsEusmCableTestTablenot-accessiblecurrentCable testing feature
1.3.6.1.4.1.629.202.3.2.1RownbsEusmCableTestEntrynot-accessiblecurrentCable testing feature
1.3.6.1.4.1.629.202.3.2.1.1ColumnnbsEusmCableTestStatusread-writecurrentTo initiate and get the status of the cable test feature. It is applicable only to copper ports. In the future we may have multiple copper ports. A GET on this…
1.3.6.1.4.1.629.202.3.2.1.2ColumnnbsEusmCableTestResultread-onlycurrentThis string will give out the result of the cable test done with a time stamp that gives the indication as to when the CableTest was initiated. This also gives…
1.3.6.1.4.1.629.202.3.3TablenbsEusmLgaTablenot-accessiblecurrentContains a description of Traffic discrepancy counters.
1.3.6.1.4.1.629.202.3.3.1RownbsEusmLgaEntrynot-accessiblecurrentDiscrepancy entry
1.3.6.1.4.1.629.202.3.3.1.1ColumnnbsEusmLgaRdAllFramesread-onlycurrentThe count of all frames (good+bad) lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.2ColumnnbsEusmLgaRducFramesread-onlycurrentThe count of good unicast frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.3ColumnnbsEusmLgaRdmcFramesread-onlycurrentThe count of good multicast frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.4ColumnnbsEusmLgaRdbcFramesread-onlycurrentThe count of good broadcast frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.5ColumnnbsEusmLgaRdSize64read-onlycurrentThe count of all 64 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.6ColumnnbsEusmLgaRdSizeMax127read-onlycurrentThe count of all 65-127 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.7ColumnnbsEusmLgaRdSizeMax255read-onlycurrentThe count of all 128-255 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.8ColumnnbsEusmLgaRdSizeMax511read-onlycurrentThe count of all 256-511 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.9ColumnnbsEusmLgaRdSizeMax1023read-onlycurrentThe count of all 512-1023 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.10ColumnnbsEusmLgaRdSizeMax1518read-onlycurrentThe count of all 1024-1518 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.11ColumnnbsEusmLgaRdSizeMax2047read-onlycurrentThe count of all 1519-2047 byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.12ColumnnbsEusmLgaRdSizeOvr2047read-onlycurrentThe count of all 2048-plus byte frames lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.13ColumnnbsEusmLgaRdFrameDivisorread-onlycurrentThe divisor to calculate frame loss/gain ratios for the most recent interval.
1.3.6.1.4.1.629.202.3.3.1.14ColumnnbsEusmLgaRdAllOctetsread-onlycurrentThe count of all frame octets lost/gained (-/+) in the most recent interval. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.15ColumnnbsEusmLgaRdOctetDivisorread-onlycurrentThe divisor to calculate octet loss/gain ratios for the most recent interval.
1.3.6.1.4.1.629.202.3.3.1.16ColumnnbsEusmLgaRdTimeSpanread-onlycurrentThe time span (tenths of a sec) for the most recent interval.
1.3.6.1.4.1.629.202.3.3.1.17ColumnnbsEusmLgaAdAllFramesread-onlycurrentThe accumulated count of all frames (good+bad) lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.18ColumnnbsEusmLgaAducFramesread-onlycurrentThe accumulated count of good unicast frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.19ColumnnbsEusmLgaAdmcFramesread-onlycurrentThe accumulated count of good multicast frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.20ColumnnbsEusmLgaAdbcFramesread-onlycurrentThe accumulated count of good broadcast frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.21ColumnnbsEusmLgaAdSize64read-onlycurrentThe accumulated count of all 64 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.22ColumnnbsEusmLgaAdSizeMax127read-onlycurrentThe accumulated count of all 65-127 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.23ColumnnbsEusmLgaAdSizeMax255read-onlycurrentThe accumulated count of all 128-255 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.24ColumnnbsEusmLgaAdSizeMax511read-onlycurrentThe accumulated count of all 256-511 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.25ColumnnbsEusmLgaAdSizeMax1023read-onlycurrentThe accumulated count of all 512-1023 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.26ColumnnbsEusmLgaAdSizeMax1518read-onlycurrentThe accumulated count of all 1024-1518 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.27ColumnnbsEusmLgaAdSizeMax2047read-onlycurrentThe accumulated count of all 1519-2047 byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.28ColumnnbsEusmLgaAdSizeOvr2047read-onlycurrentThe accumulated count of all 2048-plus byte frames lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.29ColumnnbsEusmLgaAdFrameDivisorread-onlycurrentThe divisor to calculate frame loss/gain ratios over all intervals.
1.3.6.1.4.1.629.202.3.3.1.30ColumnnbsEusmLgaAdAllOctetsread-onlycurrentThe accumulated count of all frame octets lost/gained (-/+) over all intervals. Not supported value: 0x80000000
1.3.6.1.4.1.629.202.3.3.1.31ColumnnbsEusmLgaAdOctetDivisorread-onlycurrentThe divisor to calculate octet loss/gain ratios over all intervals.
1.3.6.1.4.1.629.202.3.3.1.32ColumnnbsEusmLgaAdTimeSpanread-onlycurrentThe accumulated time span (tenths of a sec) for all intervals.
1.3.6.1.4.1.629.202.3.3.1.33ColumnnbsEusmSlotLgaIntervalread-writecurrentTraffic Analysis (loss/gain) sampling time interval (sec). Practical range allowed is 10 seconds to 1 day.
1.3.6.1.4.1.629.202.3.3.1.34ColumnnbsEusmSlotLgaActionread-writecurrentTraffic Analysis (loss/gain) activity status.
1.3.6.1.4.1.629.202.3.4TablenbsEusmPmTablenot-accessiblecurrentContains a description of Traffic discrepancy counters.
1.3.6.1.4.1.629.202.3.4.1RownbsEusmPmEntrynot-accessiblecurrentPerformance Monitoring entry
1.3.6.1.4.1.629.202.3.4.1.1ColumnnbsEusmPmAvgAllSizesread-onlycurrentThe average transit time (nanosec) for monitored frames.
1.3.6.1.4.1.629.202.3.4.1.2ColumnnbsEusmPmAvg64read-onlycurrentThe average transit time (nanosec) for monitored 64 byte frames.
1.3.6.1.4.1.629.202.3.4.1.3ColumnnbsEusmPmAvg127read-onlycurrentThe average transit time (nanosec) for monitored 65-127 byte frames.
1.3.6.1.4.1.629.202.3.4.1.4ColumnnbsEusmPmAvg255read-onlycurrentThe average transit time (nanosec) for monitored 128-255 byte frames.
1.3.6.1.4.1.629.202.3.4.1.5ColumnnbsEusmPmAvg511read-onlycurrentThe average transit time (nanosec) for monitored 256-511 byte frames.
1.3.6.1.4.1.629.202.3.4.1.6ColumnnbsEusmPmAvg1023read-onlycurrentThe average transit time (nanosec) for monitored 512-1023 byte frames.
1.3.6.1.4.1.629.202.3.4.1.7ColumnnbsEusmPmAvg1518read-onlycurrentThe average transit time (nanosec) for monitored 1024-1518 byte frames.
1.3.6.1.4.1.629.202.3.4.1.8ColumnnbsEusmPmAvg2047read-onlycurrentThe average transit time (nanosec) for monitored 1519-2047 byte frames.
1.3.6.1.4.1.629.202.3.4.1.9ColumnnbsEusmPmAvgOvr2047read-onlycurrentThe average transit time (nanosec) for monitored 2048-plus byte frames.
1.3.6.1.4.1.629.202.3.4.1.10ColumnnbsEusmPmMinAllSizesread-onlycurrentThe minimum transit time (nanosec) for monitored frames.
1.3.6.1.4.1.629.202.3.4.1.11ColumnnbsEusmPmMin64read-onlycurrentThe minimum transit time (nanosec) for monitored 64 byte frames.
1.3.6.1.4.1.629.202.3.4.1.12ColumnnbsEusmPmMin127read-onlycurrentThe minimum transit time (nanosec) for monitored 65-127 byte frames.
1.3.6.1.4.1.629.202.3.4.1.13ColumnnbsEusmPmMin255read-onlycurrentThe minimum transit time (nanosec) for monitored 128-255 byte frames.
1.3.6.1.4.1.629.202.3.4.1.14ColumnnbsEusmPmMin511read-onlycurrentThe minimum transit time (nanosec) for monitored 256-511 byte frames.
1.3.6.1.4.1.629.202.3.4.1.15ColumnnbsEusmPmMin1023read-onlycurrentThe minimum transit time (nanosec) for monitored 512-1023 byte frames.
1.3.6.1.4.1.629.202.3.4.1.16ColumnnbsEusmPmMin1518read-onlycurrentThe minimum transit time (nanosec) for monitored 1024-1518 byte frames.
1.3.6.1.4.1.629.202.3.4.1.17ColumnnbsEusmPmMin2047read-onlycurrentThe minimum transit time (nanosec) for monitored 1519-2047 byte frames.
1.3.6.1.4.1.629.202.3.4.1.18ColumnnbsEusmPmMinOvr2047read-onlycurrentThe minimum transit time (nanosec) for monitored 2048-plus byte frames.
1.3.6.1.4.1.629.202.3.4.1.19ColumnnbsEusmPmMaxAllSizesread-onlycurrentThe maximum transit time (nanosec) for monitored frames.
1.3.6.1.4.1.629.202.3.4.1.20ColumnnbsEusmPmMax64read-onlycurrentThe maximum transit time (nanosec) for monitored 64 byte frames.
1.3.6.1.4.1.629.202.3.4.1.21ColumnnbsEusmPmMax127read-onlycurrentThe maximum transit time (nanosec) for monitored 65-127 byte frames.
1.3.6.1.4.1.629.202.3.4.1.22ColumnnbsEusmPmMax255read-onlycurrentThe maximum transit time (nanosec) for monitored 128-255 byte frames.
1.3.6.1.4.1.629.202.3.4.1.23ColumnnbsEusmPmMax511read-onlycurrentThe maximum transit time (nanosec) for monitored 256-511 byte frames.
1.3.6.1.4.1.629.202.3.4.1.24ColumnnbsEusmPmMax1023read-onlycurrentThe maximum transit time (nanosec) for monitored 512-1023 byte frames.
1.3.6.1.4.1.629.202.3.4.1.25ColumnnbsEusmPmMax1518read-onlycurrentThe maximum transit time (nanosec) for monitored 1024-1518 byte frames.
1.3.6.1.4.1.629.202.3.4.1.26ColumnnbsEusmPmMax2047read-onlycurrentThe maximum transit time (nanosec) for monitored 1519-2047 byte frames.
1.3.6.1.4.1.629.202.3.4.1.27ColumnnbsEusmPmMaxOvr2047read-onlycurrentThe maximum transit time (nanosec) for monitored 2048-plus byte frames.
1.3.6.1.4.1.629.202.3.4.1.28ColumnnbsEusmPmFramesAllSizesread-onlycurrentThe count of all monitored frames.
1.3.6.1.4.1.629.202.3.4.1.29ColumnnbsEusmPmFrames64read-onlycurrentThe count of all monitored 64 byte frames.
1.3.6.1.4.1.629.202.3.4.1.30ColumnnbsEusmPmFrames127read-onlycurrentThe count of all monitored 65-127 byte frames.
1.3.6.1.4.1.629.202.3.4.1.31ColumnnbsEusmPmFrames255read-onlycurrentThe count of all monitored 128-255 byte frames.
1.3.6.1.4.1.629.202.3.4.1.32ColumnnbsEusmPmFrames511read-onlycurrentThe count of all monitored 256-511 byte frames.
1.3.6.1.4.1.629.202.3.4.1.33ColumnnbsEusmPmFrames1023read-onlycurrentThe count of all monitored 512-1023 byte frames.
1.3.6.1.4.1.629.202.3.4.1.34ColumnnbsEusmPmFrames1518read-onlycurrentThe count of all monitored 1024-1518 byte frames.
1.3.6.1.4.1.629.202.3.4.1.35ColumnnbsEusmPmFrames2047read-onlycurrentThe count of all monitored 1519-2047 byte frames.
1.3.6.1.4.1.629.202.3.4.1.36ColumnnbsEusmPmFramesOvr2047read-onlycurrentThe count of all monitored 2048-plus byte frames.
1.3.6.1.4.1.629.202.3.4.1.37ColumnnbsEusmPmOctetsAllSizesread-onlycurrentThe count of octets in all monitored frames.
1.3.6.1.4.1.629.202.3.4.1.38ColumnnbsEusmPmOctets64read-onlycurrentThe count of octets in all monitored 64 byte frames.
1.3.6.1.4.1.629.202.3.4.1.39ColumnnbsEusmPmOctets127read-onlycurrentThe count of octets in all monitored 65-127 byte frames.
1.3.6.1.4.1.629.202.3.4.1.40ColumnnbsEusmPmOctets255read-onlycurrentThe count of octets in all monitored 128-255 byte frames.
1.3.6.1.4.1.629.202.3.4.1.41ColumnnbsEusmPmOctets511read-onlycurrentThe count of octets in all monitored 256-511 byte frames.
1.3.6.1.4.1.629.202.3.4.1.42ColumnnbsEusmPmOctets1023read-onlycurrentThe count of octets in all monitored 512-1023 byte frames.
1.3.6.1.4.1.629.202.3.4.1.43ColumnnbsEusmPmOctets1518read-onlycurrentThe count of octets in all monitored 1024-1518 byte frames.
1.3.6.1.4.1.629.202.3.4.1.44ColumnnbsEusmPmOctets2047read-onlycurrentThe count of octets in all monitored 1519-2047 byte frames.
1.3.6.1.4.1.629.202.3.4.1.45ColumnnbsEusmPmOctetsOvr2047read-onlycurrentThe count of octets in all monitored 2048-plus byte frames.
1.3.6.1.4.1.629.202.3.4.1.46ColumnnbsEusmSlotPmIntervalread-writecurrentPerformance Monitoring time duration (sec). Practical range allowed is 1 minute to 1 week.
1.3.6.1.4.1.629.202.3.4.1.47ColumnnbsEusmSlotPmSelectorread-writecurrentPerformance Monitoring traffic direction selector. coToCpe(2) measures from CO's active trunk port to CPE's active trunk port. cpeToCo(3) measures from CPE's a…
1.3.6.1.4.1.629.202.3.4.1.48ColumnnbsEusmSlotPmActionread-writecurrentTraffic Analysis (performance monitoring) activity status.
1.3.6.1.4.1.629.202.3.4.1.49ColumnnbsEusmSlotPmCapabilitiesread-onlycurrentThis bitmask indicates which performance monitoring selectors this slot can support. This object is mandatory for all slots in systems where the nbsEusmSlotPmS…