MIB Viewer

NETBOTZ-DEVICE-MIB

35 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5528.50.1ScalarnetBotz-dev-hostread-writemandatoryNetbotz device's host name.
1.3.6.1.4.1.5528.50.2ScalarnetBotz-dev-domainread-writemandatoryNetbotz device's default DNS domain.
1.3.6.1.4.1.5528.50.3ScalarnetBotz-dev-ipread-writemandatoryNetbotz device's IP address.
1.3.6.1.4.1.5528.50.4ScalarnetBotz-dev-netmaskread-writemandatoryNetbotz device's netmask.
1.3.6.1.4.1.5528.50.5ScalarnetBotz-dev-gatewayread-writemandatoryNetbotz device's default gateway/router. 0.0.0.0 if not defined.
1.3.6.1.4.1.5528.50.6ScalarnetBotz-dev-primarydnsread-writemandatoryPrimary Domain Name Server. 0.0.0.0 if not defined.
1.3.6.1.4.1.5528.50.7ScalarnetBotz-dev-secondarydnsread-writemandatorySecondary Domain Name Server. 0.0.0.0 if not defined.
1.3.6.1.4.1.5528.50.8ScalarnetBotz-dev-smtpread-writemandatorySMTP server address. This is the mail server used for sending alert e-mails.
1.3.6.1.4.1.5528.50.9ScalarnetBotz-dev-smtpportread-writemandatorySMTP port. Port number of SMTP server used for sending alert e-mails.
1.3.6.1.4.1.5528.50.10ScalarnetBotz-dev-popportread-writemandatoryPOP port. Currently, not used.
1.3.6.1.4.1.5528.50.11ScalarnetBotz-dev-loglevelread-writemandatoryThis field contains the log level of the Netbotz device. Log messages will be filtered, so that only same or lower-level messages will be passed. The default l…
1.3.6.1.4.1.5528.50.12ScalarnetBotz-dev-logaddressread-writemandatoryThis field contains an IP address to receive log messages from the Netbotz device. 0.0.0.0 for no external logging.
1.3.6.1.4.1.5528.50.13ScalarnetBotz-dev-logportread-writemandatoryPort to use in conjunction with the log address, for log messages from the Netbotz device to be sent to an external IP address. 0 = no external logging.
1.3.6.1.4.1.5528.50.14ScalarnetBotz-dev-primaryemailread-writemandatoryThe primary email addresses for alerts and messages (list separated by commas for multiple addresses).
1.3.6.1.4.1.5528.50.15ScalarnetBotz-dev-secondaryemailread-writemandatoryThe secondary email address for alerts and messages (list separated by commas for multiple addresses).
1.3.6.1.4.1.5528.50.16ScalarnetBotz-dev-pagerread-writemandatoryThe pager number for alerts and messages. Currently, not used.
1.3.6.1.4.1.5528.50.17ScalarnetBotz-dev-serialnoread-onlymandatoryThe serial number of the Netbotz device.
1.3.6.1.4.1.5528.50.18ScalarnetBotz-dev-popread-writemandatoryPOP server name. Currently, not used.
1.3.6.1.4.1.5528.50.19ScalarnetBotz-dev-versionread-onlymandatoryThe current NetBotz device firmware version.
1.3.6.1.4.1.5528.50.20ScalarnetBotz-dev-registeredread-onlymandatoryIndicates if the device has been registered with Netbotz, Inc. 1=registered, 0=not registered.
1.3.6.1.4.1.5528.50.21ScalarnetBotz-default-appletread-writemandatorySetting to control if default web page should launch applet by default(1) or the HTML status page(0).
1.3.6.1.4.1.5528.50.22ScalarnetBotz-guibar-colorread-writemandatorySetting for color of GUI bar (RGB). Value = 0xRRGGBB.
1.3.6.1.4.1.5528.50.23ScalarnetBotz-localeread-writemandatoryThe locale ID of the NetBotz device. Format is ISO 639 language (lower case), an underscore, and ISO 3166 country (upper case). Some locales are just the ISO 6…
1.3.6.1.4.1.5528.50.24ScalarnetBotz-timezoneread-writemandatoryThe timezone ID of the NetBotz device.
1.3.6.1.4.1.5528.50.25ScalarnetBotz-24hourpreferredread-writemandatoryIndicates if 24-hour(1) versus 12-hour(0) time format is preferred.
1.3.6.1.4.1.5528.50.26ScalarnetBotz-utc-clockread-writemandatoryCurrent time of clock on NetBotz device, in UTC seconds (seconds since 1/1/1970 12:00am GMT).
1.3.6.1.4.1.5528.50.27ScalarnetBotz-ismetricread-onlymandatoryUnits are metric (1) or U.S. (0). Applies to temperature and airflow rate.
1.3.6.1.4.1.5528.50.28ScalarnetBotz-alert-urlread-writemandatoryThe URL, if defined, to which non-picture alerts are HTTP POSTed
1.3.6.1.4.1.5528.50.29ScalarnetBotz-picture-alert-urlread-writemandatoryThe URL, if defined, to which picture alerts are HTTP POSTed, using multipart/form-data encoding.
1.3.6.1.4.1.5528.50.30ScalarnetBotz-sensor-data-urlread-writemandatoryThe URL, if defined, to which sensor data is periodically HTTP POSTed.
1.3.6.1.4.1.5528.50.31ScalarnetBotz-alert-url-logonread-writemandatoryThe user ID and password, if defined, used for POSTing non-picture alerts. Field is write-only, and formatted /
1.3.6.1.4.1.5528.50.32ScalarnetBotz-picture-alert-url-logonread-writemandatoryThe user ID and password, if defined, used for POSTing picture alerts. Field is write-only, and formatted /
1.3.6.1.4.1.5528.50.33ScalarnetBotz-sensor-data-url-logonread-writemandatoryThe user ID and password, if defined, used for POSTing sensor data. Field is write-only, and formatted /
1.3.6.1.4.1.5528.50.34ScalarnetBotz-sensor-data-url-periodread-writemandatoryDefault number of minutes between periodic sensor data HTTP POSTs.
1.3.6.1.4.1.5528.50.35ScalarnetBotz-sensor-data-url-flagsread-writemandatoryOption flags for data POSTs of sensor data. Bit 0=1 if current picture should be included. Bits 1-31 are reserved.