MIB Viewer

PEGASUS-SDH-MIB

65 objects
This MIB applies to the PEGASUS SDSL product manufactured by Schmid Telecom Zurich. The MIB is modelled after the PEM management model, so object hierarchy and individual variables agree with the PEM client. This MIB represents an extension to the DS1-MIB and the SONET-MIB. These three MIB files are used to manage the PEGASUS STM-1 card. The PEGASUS-SDH-MIB contains five tables: - stm1CardTable one entry for each STM-1 card configured. - stm1CardClockTable one entry for each STM-1 card configured. - ethernetIfTable one entry for each Ethernet interface of a configured STM-1 card. - vcTable one entry for each Virtual Container (VC-3/4/12). - tugConfigTable one entry for each Tributary Unit Group (TUG-3). Note - The tables that represent extensions to the DS1-/SINET-MIB use the ifIndex from IF-MIB (ifTable).
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.6368.2.8IdentitypegasusSdhMibModuleThis MIB applies to the PEGASUS SDSL product manufactured by Schmid Telecom Zurich. The MIB is modelled after the PEM management model, so object hierarchy and…
1.3.6.1.4.1.6368.2.8.1Tablestm1CardTablenot-accessiblecurrentA table containing stm1 card specific information.
1.3.6.1.4.1.6368.2.8.1.1Rowstm1CardEntrynot-accessiblecurrentRow and index definition for stm1 card table.
1.3.6.1.4.1.6368.2.8.1.1.1Columnstm1CardSlotNumbernot-accessiblecurrentSlot number for stm1 card.
1.3.6.1.4.1.6368.2.8.1.1.2Columnstm1CardNameread-onlycurrentName of the PEGASUS device.
1.3.6.1.4.1.6368.2.8.1.1.3Columnstm1CardHardwareVersionread-onlycurrentHardware version of the STM-1 card. This is also called CHM-number (it always starts with the letters 'CHM'). The number '404' after 'CHM' identifies the card …
1.3.6.1.4.1.6368.2.8.1.1.4Columnstm1CardFirmwareVersionread-onlycurrentVersion number and build date of the firmware running on the line card. The format is 'major.minor YYYYMMDD hh:mm'.
1.3.6.1.4.1.6368.2.8.1.1.5Columnstm1CardManufacturerread-onlycurrentManufacturer of the STM-1 card.
1.3.6.1.4.1.6368.2.8.1.1.6Columnstm1CardSerialNumberread-onlycurrentSerial number of the line card. Also called HM-number, as it always starts with 'HM'. Example: HMVSS014810294.
1.3.6.1.4.1.6368.2.8.1.1.7Columnstm1CardMultiplexingModeread-writecurrentSelects the SDH multiplexing mode. Either it is STM1-AU3-VC3 or STM1-AU4-VC4.
1.3.6.1.4.1.6368.2.8.1.1.8Columnstm1CardJ0TraceMonitoringread-writecurrentIf trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted.
1.3.6.1.4.1.6368.2.8.1.1.9Columnstm1CardJ1TraceMonitoringread-writecurrentIf trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted.
1.3.6.1.4.1.6368.2.8.1.1.10Columnstm1CardJ2TraceMonitoringread-writecurrentIf trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted.
1.3.6.1.4.1.6368.2.8.1.1.11Columnstm1CardJ0PathTraceSizeread-writecurrentSize of the Regenerator Section Trace Message.
1.3.6.1.4.1.6368.2.8.1.1.12Columnstm1CardJ0PathTraceSendread-writecurrentConfigurable Regenerator Section (RS) Trace Message.
1.3.6.1.4.1.6368.2.8.1.1.13Columnstm1CardJ0PathTraceExpectedread-writecurrentRegenerator Section (RS) Trace Message that should be received.
1.3.6.1.4.1.6368.2.8.1.1.14Columnstm1CardJ0PathTraceReceiveread-onlycurrentRegenerator Section (RS) Trace Message that is be received.
1.3.6.1.4.1.6368.2.8.1.1.15Columnstm1CardLaserOperationModeread-writecurrentConfiguration of the 'Automatic Laser Shutdown' feature.
1.3.6.1.4.1.6368.2.8.1.1.16Columnstm1CardLaserStateread-onlycurrentActual state of the laser.
1.3.6.1.4.1.6368.2.8.1.1.17Columnstm1CardOperStateread-onlycurrentThe operational state is a status property indicating whether or not a device is physically installed and working. enabled The device is partially or fully ope…
1.3.6.1.4.1.6368.2.8.1.1.18Columnstm1CardAvailabilityStateread-onlycurrentThe availability status gives more detailed information about failures within a device. An empty status set means that no error exists. Possible status are: in…
1.3.6.1.4.1.6368.2.8.1.1.19Columnstm1CardMgmtCommStateread-onlycurrentThe Management Comm State indicates the state of the management connection between the PEM Server and the STM-1 card. disconnected No connection has been estab…
1.3.6.1.4.1.6368.2.8.1.1.20Columnstm1CardPRBSGeneratorSinkread-writecurrentDetermines, whether the PRBS Generator should be used on the optical or on the E1 links.
1.3.6.1.4.1.6368.2.8.1.1.21Columnstm1CardPRBSAnalyzerSourceread-writecurrentDetermines, whether the PRBS Analyzer should be used on the optical or on the E1 links.
1.3.6.1.4.1.6368.2.8.1.1.22Columnstm1CardPRBSPatternread-writecurrentDetermines the PRBS Pattern to be used.
1.3.6.1.4.1.6368.2.8.1.1.23Columnstm1CardAlarmStatusread-onlycurrentThis variable indicates the status of STM-1 card, regenerator section and multiplex section. It's a bitmap represented as a sum. Therefore multiple alarms can …
1.3.6.1.4.1.6368.2.8.2Tablestm1CardClockTablenot-accessiblecurrentA table containing stm1 card specific clock information.
1.3.6.1.4.1.6368.2.8.2.1Rowstm1CardClockEntrynot-accessiblecurrentRow and index definition for stm1 card clock table.
1.3.6.1.4.1.6368.2.8.2.1.1Columnstm1CardActiveClockSourceread-onlycurrentDisplays which clock sourceis active and used as sync source.
1.3.6.1.4.1.6368.2.8.2.1.2Columnstm1CardClockSyncStateread-onlycurrentSync status is OK if RX or Reference clock is valid and used as active sync source.
1.3.6.1.4.1.6368.2.8.2.1.3Columnstm1CardTxLineClockQualityread-writecurrentThis is the clock quality of the outgoing SDH signal. The default sets the outgoing quality to the incoming quality. Sometime it may be useful to set a fix out…
1.3.6.1.4.1.6368.2.8.2.1.4Columnstm1CardRxClockModeread-writecurrentIf enabled the RX line clock can be used as sync source.
1.3.6.1.4.1.6368.2.8.2.1.5Columnstm1CardRxClockPriorityread-writecurrentThis value has always the opposite value of Reference Clock Priority.
1.3.6.1.4.1.6368.2.8.2.1.6Columnstm1CardRxClockQualityread-onlycurrentThis is the clock quality of the incoming SDH signal.
1.3.6.1.4.1.6368.2.8.2.1.7Columnstm1CardRxClockStateread-onlycurrentClock status is valid if a good clock can be found on input (clock checker).
1.3.6.1.4.1.6368.2.8.2.1.8Columnstm1CardReferenceClockModeread-writecurrentIf enabled the Reference clock (V5 card input) can be used as sync source.
1.3.6.1.4.1.6368.2.8.2.1.9Columnstm1CardReferenceClockPriorityread-writecurrentThis value has always the opposite value of Rx Clock Priority.
1.3.6.1.4.1.6368.2.8.2.1.10Columnstm1CardReferenceClockQualityread-writecurrentDefines the quality of the reference clock input. This value will be transmitted in SDH-TX if reference clock is used as active sync source.
1.3.6.1.4.1.6368.2.8.2.1.11Columnstm1CardReferenceClockStateread-onlycurrentClock status is valid if a good clock can be found on input (clock checker).
1.3.6.1.4.1.6368.2.8.3TableethernetIfTablenot-accessiblecurrentThis table contains additional information concerning the ethernet interfaces of a STM-1 card. It represents an extension of the if(X)Table (see IF-MIB).
1.3.6.1.4.1.6368.2.8.3.1RowethernetIfEntrynot-accessiblecurrentRow and index definition for the ethernetIfTable.
1.3.6.1.4.1.6368.2.8.3.1.1ColumnetherIfConcatenationOptionread-writecurrentConfiguration of the Link Capacity Adjustment Scheme.
1.3.6.1.4.1.6368.2.8.3.1.2ColumnetherIfEncapsulationread-onlycurrentThis attribute shows the used Ethernet encapsulation protocol.
1.3.6.1.4.1.6368.2.8.3.1.3ColumnetherIfOrderLevelread-onlycurrentOnly relevant, if SDH Multiplexing Mode (see STM-1 card propertied) is set to VC3.
1.3.6.1.4.1.6368.2.8.3.1.4ColumnetherIfAlarmStatusread-onlycurrentThis variable indicates the status of an Ethernet Interface. It's a bitmap represented as a sum. Therefore multiple defects can be displayed simultaneously. Th…
1.3.6.1.4.1.6368.2.8.4TablevcTablenot-accessiblecurrentThis table contains additional information for VC concerning the multiplexing configuration. It's an extension of the ifTable (IF-MIB) and the tables of the SO…
1.3.6.1.4.1.6368.2.8.4.1RowvcEntrynot-accessiblecurrentRow and index definition for the vcConfigTable.
1.3.6.1.4.1.6368.2.8.4.1.1ColumnvcTyperead-onlycurrentType of Virtual Container (VC). In Pegasus VC-4, VC-3 or VC-12.
1.3.6.1.4.1.6368.2.8.4.1.2ColumnvcRelatedTUGread-onlycurrentRepresents the index of the Tributary Unit Group within the tugConfigTable to which this VC is assigned to. The value depends also on the multiplexing mode. If…
1.3.6.1.4.1.6368.2.8.4.1.3ColumnvcRelatedVCread-onlycurrentRepresents the index of the Virtual Container within the ifTable to which this VC is assigned to. The value depends also on the multiplexing mode. If the value…
1.3.6.1.4.1.6368.2.8.4.1.4ColumnvcAssignedIfIndexread-writecurrentRepresents the index of the interface within the ifTable (IF-MIB) that transmits to this VC.
1.3.6.1.4.1.6368.2.8.4.1.5ColumnvcPathTraceSendread-writecurrentThe value of the outgoing J1 Byte VC Path Trace byte message.
1.3.6.1.4.1.6368.2.8.4.1.6ColumnvcPathTraceExpectedread-writecurrentThe value of the expected J1 Byte VC Path Trace byte message.
1.3.6.1.4.1.6368.2.8.4.1.7ColumnvcPathTraceReceiveread-onlycurrentThe value of the incoming J1 Byte VC Path Trace byte message.
1.3.6.1.4.1.6368.2.8.4.1.8ColumnvcSignalLabelSendread-writecurrentThe outgoing C2 VC Signal Label (0x02 = TUG structure).
1.3.6.1.4.1.6368.2.8.4.1.9ColumnvcSignalLabelExpectedread-writecurrentThe expected C2 VC Signal Label (0x02 = TUG structure).
1.3.6.1.4.1.6368.2.8.4.1.10ColumnvcSignalLabelReceiveread-onlycurrentThe incoming C2 VC Signal Label (0x02 = TUG structure).
1.3.6.1.4.1.6368.2.8.4.1.11ColumnvcAlarmStatusread-onlycurrentThis variable indicates the status of the VC. It's a bitmap represented as a sum. Therefore multiple defects can be displayed simultaneously. The value noDefec…
1.3.6.1.4.1.6368.2.8.5TabletugConfigTablenot-accessiblecurrentThis table contains information concerning Tributary Unit Groups. If AU-3 structure is used, this table is empty.
1.3.6.1.4.1.6368.2.8.5.1RowtugConfigEntrynot-accessiblecurrentRow and index definition for the tugConfigTable.
1.3.6.1.4.1.6368.2.8.5.1.1ColumntugIndexnot-accessiblecurrentNumber of the TUG. Range 1..3
1.3.6.1.4.1.6368.2.8.5.1.2ColumntugRelatedVC4read-onlycurrent
1.3.6.1.4.1.6368.2.8.5.1.3ColumntugOrderLevelread-writecurrentIndividual Order Level of this TUG. If high order is used, the TUG has exactly one VC-3 and no VC-12s. If low order is used, the TUG has exactly 21 VC-12 and n…
1.3.6.1.4.1.6368.2.8.6ScalarsdhMibRevisionread-onlycurrentThe version number assigned by the version control system. You can query this from the agent, to find out with which version of the MIB was built into the agen…
Type Definitions
NameSyntaxStatusDescription
SignalLabelINTEGER(0..7|18..26|207|225..252|254..255) ConcatenationTypeEnum ::= INTEGER { lcas(1), nonLCAS(2) } EthernetIfEncapsulationEnum ::= INTEGER { disabled(1), gfp(2), lapf(3), laps(4), ppp(5) } OrderLevelEnum ::= INTEGER { highOrder(1), lowOrder(2) } STM1SlotNumber ::= INTEGER(2) TUGIndex ::= INTEGER(1..3) TUGIndexOrZero ::= INTEGER(0..3)currentRepresentation of a VC Signal Label. The meaning of the SignalLabel depends on the type of vitual container. VC-12s use the following values: 001b Unequipped 001b Equipped (non specific) 010b Asynchronous 011b Bit Synch…