MIB Viewer

POWER-ATTRIBUTES-MIB

40 objects
Copyright (c) 2015 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info). This MIB is used to report AC power attributes in devices. The table is a sparse augmentation of the eoPowerTable table from the energyObjectMib module. Both three-phase and single-phase power configurations are supported. As a requirement for this MIB module, RFC 7461 SHOULD be implemented. Module Compliance of ENTITY-MIB v4 with respect to entity4CRCompliance MUST be supported which requires implementation of four MIB objects: entPhysicalIndex, entPhysicalClass, entPhysicalName, and entPhysicalUUID.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.2.1.230IdentitypowerAttributesMIBCopyright (c) 2015 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with o…
1.3.6.1.2.1.230.0NodepowerAttributesMIBConform
1.3.6.1.2.1.230.1NodepowerAttributesMIBObjects
1.3.6.1.2.1.230.1.1TableeoACPwrAttributesTablenot-accessiblecurrentThis table contains power attributes measurements for supported entPhysicalIndex entities. It is a sparse extension of the eoPowerTable.
1.3.6.1.2.1.230.1.1.1RoweoACPwrAttributesEntrynot-accessiblecurrentThis is a sparse extension of the eoPowerTable with entries for power attributes measurements or configuration. Each measured value corresponds to an attribute…
1.3.6.1.2.1.230.1.1.1.1ColumneoACPwrAttributesConfigurationread-onlycurrentConfiguration describes the physical configurations of the power supply lines: * alternating current, single phase (SNGL) * alternating current, three-phase de…
1.3.6.1.2.1.230.1.1.1.2ColumneoACPwrAttributesAvgVoltageread-onlycurrentA measured value for average of the voltage measured over an integral number of AC cycles. For a three-phase system, this is the average voltage (V1+V2+V3)/3. …
1.3.6.1.2.1.230.1.1.1.3ColumneoACPwrAttributesAvgCurrentread-onlycurrentA measured value for average of the current measured over an integral number of AC cycles. For a three-phase system, this is the average current (I1+I2+I3)/3. …
1.3.6.1.2.1.230.1.1.1.4ColumneoACPwrAttributesFrequencyread-onlycurrentA measured value for the basic frequency of the AC circuit. IEC 61850-7-4 attribute 'Hz'.
1.3.6.1.2.1.230.1.1.1.5ColumneoACPwrAttributesPowerUnitMultiplierread-onlycurrentThe magnitude of watts for the usage value in eoACPwrAttributesTotalActivePower, eoACPwrAttributesTotalReactivePower, and eoACPwrAttributesTotalApparentPower m…
1.3.6.1.2.1.230.1.1.1.6ColumneoACPwrAttributesPowerAccuracyread-onlycurrentThis object indicates a percentage value, in hundredths of a percent, representing the presumed accuracy of active, reactive, and apparent power usage reportin…
1.3.6.1.2.1.230.1.1.1.7ColumneoACPwrAttributesTotalActivePowerread-onlycurrentA measured value of the actual power delivered to or consumed by the load. IEC 61850-7-4 attribute 'TotW'.
1.3.6.1.2.1.230.1.1.1.8ColumneoACPwrAttributesTotalReactivePowerread-onlycurrentA measured value of the reactive portion of the apparent power. IEC 61850-7-4 attribute 'TotVAr'.
1.3.6.1.2.1.230.1.1.1.9ColumneoACPwrAttributesTotalApparentPowerread-onlycurrentA measured value of the voltage and current that determines the apparent power. The apparent power is the vector sum of real and reactive power. Note: watts an…
1.3.6.1.2.1.230.1.1.1.10ColumneoACPwrAttributesTotalPowerFactorread-onlycurrentA measured value ratio of the real power flowing to the load versus the apparent power. It is dimensionless and expressed here as a percentage value in hundred…
1.3.6.1.2.1.230.1.1.1.11ColumneoACPwrAttributesThdCurrentread-onlycurrentA calculated value for the current total harmonic distortion (THD). Method of calculation is not specified. IEC 61850-7-4 attribute 'ThdAmp'.
1.3.6.1.2.1.230.1.1.1.12ColumneoACPwrAttributesThdVoltageread-onlycurrentA calculated value for the voltage total harmonic distortion (THD). The method of calculation is not specified. IEC 61850-7-4 attribute 'ThdVol'.
1.3.6.1.2.1.230.1.2TableeoACPwrAttributesDelPhaseTablenot-accessiblecurrentThis optional table describes three-phase power attributes measurements in a DEL configuration with phase-to-phase power attributes measurements. Entities havi…
1.3.6.1.2.1.230.1.2.1RoweoACPwrAttributesDelPhaseEntrynot-accessiblecurrentAn entry describes power measurements of a phase in a DEL three-phase power. Three entries are required for each supported entPhysicalIndex entry. Voltage meas…
1.3.6.1.2.1.230.1.2.1.1ColumneoACPwrAttributesDelPhaseIndexnot-accessiblecurrentA phase angle typically corresponding to 0, 120, 240.
1.3.6.1.2.1.230.1.2.1.2ColumneoACPwrAttributesDelPhaseToNextPhaseVoltageread-onlycurrentA measured value of phase to next phase voltages, where the next phase is IEC 61850-7-4 attribute 'PPV'.
1.3.6.1.2.1.230.1.2.1.3ColumneoACPwrAttributesDelThdPhaseToNextPhaseVoltageread-onlycurrentA calculated value for the voltage total harmonic distortion for phase to next phase. Method of calculation is not specified. IEC 61850-7-4 attribute 'ThdPPV'.
1.3.6.1.2.1.230.1.3TableeoACPwrAttributesWyePhaseTablenot-accessiblecurrentThis optional table describes three-phase power attributes measurements in a WYE configuration with phase-to-neutral power attributes measurements. Entities ha…
1.3.6.1.2.1.230.1.3.1RoweoACPwrAttributesWyePhaseEntrynot-accessiblecurrentThis table describes measurements of a phase in a WYE three-phase power system. Three entries are required for each supported entPhysicalIndex entry. Voltage m…
1.3.6.1.2.1.230.1.3.1.1ColumneoACPwrAttributesWyePhaseIndexnot-accessiblecurrentA phase angle typically corresponding to 0, 120, 240.
1.3.6.1.2.1.230.1.3.1.2ColumneoACPwrAttributesWyePhaseToNeutralVoltageread-onlycurrentA measured value of phase to neutral voltage. IEC 61850-7-4 attribute 'PNV'.
1.3.6.1.2.1.230.1.3.1.3ColumneoACPwrAttributesWyeCurrentread-onlycurrentA measured value of phase currents. IEC 61850-7-4 attribute 'A'.
1.3.6.1.2.1.230.1.3.1.4ColumneoACPwrAttributesWyeActivePowerread-onlycurrentA measured value of the actual power delivered to or consumed by the load with the magnitude indicated separately in eoPowerUnitMultiplier. IEC 61850-7-4 attri…
1.3.6.1.2.1.230.1.3.1.5ColumneoACPwrAttributesWyeReactivePowerread-onlycurrentA measured value of the reactive portion of the apparent power with the magnitude of indicated separately in eoPowerUnitMultiplier. IEC 61850-7-4 attribute 'VA…
1.3.6.1.2.1.230.1.3.1.6ColumneoACPwrAttributesWyeApparentPowerread-onlycurrentA measured value of the voltage and current determines the apparent power with the indicated separately in eoPowerUnitMultiplier. Active plus reactive power eq…
1.3.6.1.2.1.230.1.3.1.7ColumneoACPwrAttributesWyePowerFactorread-onlycurrentA measured value ratio of the real power flowing to the load versus the apparent power for this phase. IEC 61850-7-4 attribute 'PF'. Power Factor can be positi…
1.3.6.1.2.1.230.1.3.1.8ColumneoACPwrAttributesWyeThdCurrentread-onlycurrentA calculated value for the voltage total harmonic distortion (THD) for phase to phase. Method of calculation is not specified. IEC 61850-7-4 attribute 'ThdA'.
1.3.6.1.2.1.230.1.3.1.9ColumneoACPwrAttributesWyeThdPhaseToNeutralVoltageread-onlycurrentA calculated value of the voltage total harmonic distortion (THD) for phase to neutral. IEC 61850-7-4 attribute 'ThdPhV'.
1.3.6.1.2.1.230.2NodepowerAttributesMIBCompliances
1.3.6.1.2.1.230.2.1CompliancepowerAttributesMIBFullCompliancecurrentWhen this MIB is implemented with support for read- create, then such an implementation can claim full compliance. Such devices can then be both monitored and …
1.3.6.1.2.1.230.3NodepowerAttributesMIBGroups
1.3.6.1.2.1.230.3.1GrouppowerACPwrAttributesMIBTableGroupcurrentThis group contains the collection of all the power attributes objects related to the Energy Object.
1.3.6.1.2.1.230.3.2GrouppowerACPwrAttributesOptionalMIBTableGroupcurrentThis group contains the collection of all the power attributes objects related to the Energy Object.
1.3.6.1.2.1.230.3.3GrouppowerACPwrAttributesDelPhaseMIBTableGroupcurrentThis group contains the collection of all power attributes of a phase in a DEL three-phase power system.
1.3.6.1.2.1.230.3.4GrouppowerACPwrAttributesWyePhaseMIBTableGroupcurrentThis group contains the collection of all power attributes of a phase in a WYE three-phase power system.