This module includes configuration parameters for DS1 modules not included in DS1-MIB.
Imported Objects
DS1-MIBdsx1ConfigEntry
PRVT-SWITCH-MIBswitch
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIGauge32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCTEXTUAL-CONVENTION TimeStamp
OIDNameAccessStatusDescription
1.3.6.1.4.1.738.1.5.111IdentityprvtCESMibThis module includes configuration parameters for DS1 modules not included in DS1-MIB.
1.3.6.1.4.1.738.1.5.111.0NodeprvtCESNotifications
1.3.6.1.4.1.738.1.5.111.0.1NotificationprvtCESDsx1AlarmcurrentThis notification is sent when the value of a TDM port error condition statistic has exceeded the configured threshold.
1.3.6.1.4.1.738.1.5.111.0.2NotificationprvtCESModuleAvailablecurrentprvtCESModuleAvailable trap
1.3.6.1.4.1.738.1.5.111.0.3NotificationprvtCESModuleUnAvailableDueExtractcurrentprvtCESModuleUnAvailableDueExtract trap.
1.3.6.1.4.1.738.1.5.111.0.4NotificationprvtCESModuleUnAvailableDueReloadcurrentprvtCESModuleUnAvailableDueReload trap
1.3.6.1.4.1.738.1.5.111.1NodeprvtCESObjects
1.3.6.1.4.1.738.1.5.111.1.1TableprvtCESDsx1ExtTablenot-accessiblecurrentThis table contains object for configuring DS1 interfaces, not supported in dsx1ConfigTable.
1.3.6.1.4.1.738.1.5.111.1.1.1RowprvtCESDsx1ExtEntrynot-accessiblecurrentprvtCESDsx1ExtEntry
1.3.6.1.4.1.738.1.5.111.1.1.1.1ColumnprvtCESE1Impedanceread-writecurrentThis object configures temination impedance for TDM ports if the line type is E1.
1.3.6.1.4.1.738.1.5.111.1.1.1.2ColumnprvtCEST1GainLimitread-writecurrentThis object configures Tx or Rx gain limit for TDM ports if the line type is T1.
1.3.6.1.4.1.738.1.5.111.1.1.1.3ColumnprvtCESPortShutdownread-writecurrentShutdown TDM port.
1.3.6.1.4.1.738.1.5.111.1.1.1.4ColumnprvtCESPortLineTyperead-writecurrentAdditional line types. For reference see object dsx1LineType
1.3.6.1.4.1.738.1.5.111.1.1.1.5ColumnprvtCEST1LongCableLengthread-writecurrentLong cable length options for T1 mode.
1.3.6.1.4.1.738.1.5.111.1.1.1.6ColumnprvtCESPortOperStatusread-onlycurrentTDM link state.
1.3.6.1.4.1.738.1.5.111.1.1.1.7ColumnprvtCESClearPortStatisticsread-writecurrentClear port statistics.
1.3.6.1.4.1.738.1.5.111.1.1.1.8ColumnprvtCESServiceClockread-writecurrentService Clock available only for DS1 interface.
1.3.6.1.4.1.738.1.5.111.1.2TableprvtCESModuleConfTablenot-accessiblecurrentThis table contains object for configuring options that are applied to the entire module.
1.3.6.1.4.1.738.1.5.111.1.2.1RowprvtCESModuleConfEntrynot-accessiblecurrentprvtCESModuleConfEntry
1.3.6.1.4.1.738.1.5.111.1.2.1.1ColumnprvtCESModuleIndexaccessible-for-notifycurrentIndex of each CES module installed.
1.3.6.1.4.1.738.1.5.111.1.2.1.2ColumnprvtCESModuleLineTyperead-writecurrentLine mode for the module.
1.3.6.1.4.1.738.1.5.111.1.2.1.3ColumnprvtCESModuleTxClockread-writecurrentConfigures Transmit Source Clock for the module.
1.3.6.1.4.1.738.1.5.111.1.2.1.4ColumnprvtCESModuleTxBackupClockread-writecurrentConfigures Backup Clock for the module.
1.3.6.1.4.1.738.1.5.111.1.2.1.5ColumnprvtCESModuleConfigread-writecurrentWhen this object is set to applyConfiguration(2), the module is restarted and the changes in dsx1ConfigTable or prvtCESConfTable are applied. The object must b…
1.3.6.1.4.1.738.1.5.111.1.2.1.6ColumnprvtCESModuleIPAddressread-writecurrentThe CES Module IP address after configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.2.1.7ColumnprvtCESModuleIPAddressMaskread-writecurrentThe CES Module IP address mask after configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.2.1.8ColumnprvtCESModuleGatewayread-writecurrentCES Module Gateway after configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.2.1.9ColumnprvtCESModuleUpTimeread-onlycurrentCES Up Time
1.3.6.1.4.1.738.1.5.111.1.2.1.10ColumnprvtCESModuleMACAddressread-onlycurrentCES MAC Address
1.3.6.1.4.1.738.1.5.111.1.2.1.11ColumnprvtCESModuleHardwareRevisionread-onlycurrentCES Hardware revision
1.3.6.1.4.1.738.1.5.111.1.2.1.12ColumnprvtCESModuleFirmwareVersionread-onlycurrentCES Firmware revision
1.3.6.1.4.1.738.1.5.111.1.2.1.13ColumnprvtCESModuleClearCircuitStatisticsread-writecurrentClear circuits statistics.
1.3.6.1.4.1.738.1.5.111.1.2.1.14ColumnprvtCESModuleLbitread-writecurrentEnable/disable L bit set upon AIS defect detection, in structure agnostic mode.
1.3.6.1.4.1.738.1.5.111.1.2.1.15ColumnprvtCESModulePolicyLopsread-writecurrentControls policy lops. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.16ColumnprvtCESModulePolicyLbitread-writecurrentControls policy lbit. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.17ColumnprvtCESModulePolicyRbitread-writecurrentControls policy rbit. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.18ColumnprvtCESModulePolicyRdread-writecurrentControls policy rd. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.19ColumnprvtCESModulePolicyIdlePatternread-writecurrentControls policy idle pattern. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.20ColumnprvtCESModulePolicyIdleSignallingread-writecurrentControls policy idle signalling. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.21ColumnprvtCESModulePolicyLopsEnterread-writecurrentControls the number of consecutive missed packets required to enter LOPS state. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.22ColumnprvtCESModulePolicyLopsExitread-writecurrentControls the number of consecutive missed packets required to exit LOPS state. Object does not require module to be restarted.
1.3.6.1.4.1.738.1.5.111.1.2.1.23ColumnprvtCESModulePolicyuUnstrLbitread-writecurrentIf a packet is received with L bit set, and the payload is present (not suppressed), one of the following is sent to the TDM line, according to a globally conf…
1.3.6.1.4.1.738.1.5.111.1.2.1.24ColumnprvtCESModulePolicyuStrReplaceread-writecurrentIf a missing packet is detected, one of the following is sent to the TDM line, according to a globally configurable structured missing packet replacement polic…
1.3.6.1.4.1.738.1.5.111.1.2.1.25ColumnprvtCESModulePolicyuUnstrReplaceread-writecurrentIf a missing packet is detected, one of the following is sent to the TDM line, according to a globally configurable unstructured missing packet replacement pol…
1.3.6.1.4.1.738.1.5.111.1.2.1.26ColumnprvtCESModulePolicyuUnstrLopsread-writecurrentIf a CES circuit enters the LOPS state, one of the following is sent to the TDM line, according to a globally configurable unstructured missing packet replacem…
1.3.6.1.4.1.738.1.5.111.1.2.1.27ColumnprvtCESModuleServiceClockread-writecurrentClock mode for CES module
1.3.6.1.4.1.738.1.5.111.1.2.1.28ColumnprvtCESModulePolicyuUnstrReplacePatternread-writecurrentUnstructured packet replace policy pattern number
1.3.6.1.4.1.738.1.5.111.1.3TableprvtCESUnappTablenot-accessiblecurrentThis table displays CES module configuration which will take effect after prvtCESModuleConf is set to applyConfiguration(2).
1.3.6.1.4.1.738.1.5.111.1.3.1RowprvtCESUnappEntrynot-accessiblecurrentprvtCESUnappEntry
1.3.6.1.4.1.738.1.5.111.1.3.1.1ColumnprvtCESUnappLineTyperead-onlycurrentThe value of dsx1LineType before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.2ColumnprvtCESUnappLineCodingread-onlycurrentThe value of dsx1LineCoding before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.3ColumnprvtCESUnappLoopbackConfigread-onlycurrentThe value of dsx1LoopbackConfig before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.4ColumnprvtCESUnappSignalModeread-onlycurrentThe value of dsx1SignalMode before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.5ColumnprvtCESUnappTransmitClockSourceread-onlycurrentThe value of dsx1TransmitClockSource before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.6ColumnprvtCESUnappTransmitClockBackupread-onlycurrentThe value of dsx1TransmitClockBackup before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.7ColumnprvtCESUnappLineLengthread-onlycurrentThe value of dsx1LineLength before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.8ColumnprvtCESUnappLineModeread-onlycurrentThe value of dsx1LineMode before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.9ColumnprvtCESUnappLineBuildOutread-onlycurrentThe value of dsx1LineBuildOut before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.10ColumnprvtCESUnappE1Impedanceread-onlycurrentThe value of prvtCESE1Impedance before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.11ColumnprvtCESUnappT1GainLimitread-onlycurrentThe value of prvtCEST1GainLimit before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.12ColumnprvtCESUnappIPAddressread-onlycurrentThe CES Module IP address before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.13ColumnprvtCESUnappIPAddressMaskread-onlycurrentThe CES Module IP address mask before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.3.1.14ColumnprvtCESUnappGatewayread-onlycurrentThe CES Module Gateway before configuration is applied.
1.3.6.1.4.1.738.1.5.111.1.4TableprvtCESDsx1AlarmTablenot-accessiblecurrentThis table contains object for configuring and displaying TDM ports TCA thresholds.
1.3.6.1.4.1.738.1.5.111.1.4.1RowprvtCESDsx1AlarmEntrynot-accessiblecurrentprvtCESDsx1AlarmEntry
1.3.6.1.4.1.738.1.5.111.1.4.1.1ColumnprvtCESDsx1AlarmPortnot-accessiblecurrentThe DS1 port for which this alarm is configured.
1.3.6.1.4.1.738.1.5.111.1.4.1.2ColumnprvtCESDsx1AlarmIndexnot-accessiblecurrentAn integer uniquely identifying an alarm entry.
1.3.6.1.4.1.738.1.5.111.1.4.1.3ColumnprvtCESDsx1AlarmVariableread-onlycurrentThe OID of the variable whose value is being monitored. Depending on the time interval, the error condition and the ifIndex of the TDM interface, this points t…
1.3.6.1.4.1.738.1.5.111.1.4.1.4ColumnprvtCESDsx1AlarmThresholdread-writecurrentThe alarm condition threshold for this alarm entry. The alarm is triggered if the value of the object pointed by prvtCESDsx1AlarmVariable remains above this th…
1.3.6.1.4.1.738.1.5.111.1.4.1.5ColumnprvtCESDsx1AlarmValueaccessible-for-notifycurrentThe value of the object pointed to by prvtCESDsx1AlarmVariable, present for notification purposes.
1.3.6.1.4.1.738.1.5.111.1.5ScalarprvtCESAlarmMonitorread-writecurrentCES alarm monitor
1.3.6.1.4.1.738.1.5.111.1.6TableprvtCESCICTablenot-accessiblecurrentThis table contains objects for configuring Clock Input Controller.
1.3.6.1.4.1.738.1.5.111.1.6.1RowprvtCESCICEntrynot-accessiblecurrentprvtCESCICEntry
1.3.6.1.4.1.738.1.5.111.1.6.1.1ColumnprvtCESCICModuleIdnot-accessiblecurrentSlot of CES module installed.
1.3.6.1.4.1.738.1.5.111.1.6.1.2ColumnprvtCESCICNumbernot-accessiblecurrentAn integer uniquely identifying a Clock Input Controller.
1.3.6.1.4.1.738.1.5.111.1.6.1.3ColumnprvtCESCICClockNumberread-onlycurrentThis variable indicates the index of the clock the clock input controller belongs to
1.3.6.1.4.1.738.1.5.111.1.6.1.4ColumnprvtCESCICModeread-onlycurrentThe mode of the clock input controller. Not all clock input controllers support all modes. The clock input controller status is 'locked' only if the clock inpu…
1.3.6.1.4.1.738.1.5.111.1.6.1.5ColumnprvtCESCICTdmPortread-writecurrentIf the clock input controller recovers a clock from a port , this variable indicates the TDM Port. Otherwise, it must be set to zero.
1.3.6.1.4.1.738.1.5.111.1.6.1.6ColumnprvtCESCICCircuitread-writecurrentIf the clock input controller recovers a clock from a circuit, this variable indicates the circuit ID. Otherwise, it must be set to zero.
1.3.6.1.4.1.738.1.5.111.1.6.1.7ColumnprvtCESCICStatusread-onlycurrentThe status of the input reference.Reference is ok when the status is 'locked'. Otherwise, the status is 'notLocked'. Alternatively, if an error was detected at…
1.3.6.1.4.1.738.1.5.111.1.6.1.8ColumnprvtCESCICStateread-onlycurrentThe state is set to 'active' if the input controller was selected by the clock to drive the clock output. At least one input out of the clock-input-controllers…
1.3.6.1.4.1.738.1.5.111.1.7TableprvtCESCICMappTablenot-accessiblecurrentThis table contains clock configuration and status monitoring information.
1.3.6.1.4.1.738.1.5.111.1.7.1RowprvtCESCICMappEntrynot-accessiblecurrentprvtCESCICMappEntry
1.3.6.1.4.1.738.1.5.111.1.7.1.1ColumnprvtCESCICMappModuleIdread-onlycurrentSlot of CES module installed.
1.3.6.1.4.1.738.1.5.111.1.7.1.2ColumnprvtCESCICMappClockNumberread-onlycurrentIndex for the conceptual row identifying a clock within this mapping table
1.3.6.1.4.1.738.1.5.111.1.7.1.3ColumnprvtCESCICMappCICNumberread-onlycurrentIndex for the conceptual row identifying a clock input within this mapping table
1.3.6.1.4.1.738.1.5.111.1.7.1.4ColumnprvtCESCICMappStateread-onlycurrentThe state is set to 'active' if the input controller was selected by the clock to drive the clock output. At least one input out of the clock-input-controllers…
1.3.6.1.4.1.738.1.5.111.1.8TableprvtCESApsTablenot-accessiblecurrentThis table contains objects needed APS configuration
1.3.6.1.4.1.738.1.5.111.1.8.1RowprvtCESApsEntrynot-accessiblecurrentprvtCESApsEntry
1.3.6.1.4.1.738.1.5.111.1.8.1.1ColumnprvtCESApsModuleIdnot-accessiblecurrentAn integer uniquely identifying slot of the CES module installed
1.3.6.1.4.1.738.1.5.111.1.8.1.2ColumnprvtCESApsEnableread-writecurrentEnable/Disable Automatic Protection Switching
1.3.6.1.4.1.738.1.5.111.1.8.1.3ColumnprvtCESApsActiveLineread-writecurrentAPS active line
1.3.6.1.4.1.738.1.5.111.1.8.1.4ColumnprvtSdBerThresholdread-writecurrentThe Signal Degrade Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER…
1.3.6.1.4.1.738.1.5.111.1.8.1.5ColumnprvtSfBerThresholdread-writecurrentThe Signal Failure Bit Error Rate. The negated value of this number is used as the exponent of 10 for computing the threshold value for the Bit Error Rate (BER…
1.3.6.1.4.1.738.1.5.111.1.9TableprvtCESUpdateFirmwareTablenot-accessiblecurrentThis table contains object needed in update firmware of CES module
1.3.6.1.4.1.738.1.5.111.1.9.1RowprvtCESUpdateFirmwareEntrynot-accessiblecurrentprvtCESUpdateFirmwareEntry
1.3.6.1.4.1.738.1.5.111.1.9.1.1ColumnprvtCESModuleIdnot-accessiblecurrentAn integer uniquely identifying slot of the CES module installed
1.3.6.1.4.1.738.1.5.111.1.9.1.2ColumnprvtCESFirmwareImageNameread-writecurrentName of the firmware image file
1.3.6.1.4.1.738.1.5.111.1.9.1.3ColumnprvtCESUpdateActionread-writecurrentUpdate CES firmware
1.3.6.1.4.1.738.1.5.111.1.9.1.4ColumnprvtCESUpdateStatusread-onlycurrentThe status of the last update procedure, if any. This object will have a value of updateStatusUnknown(2) if no update process has been performed.
1.3.6.1.4.1.738.1.5.111.1.9.1.5ColumnprvtCESTFTPServerread-writecurrentIP Address of Tftp Server
1.3.6.1.4.1.738.1.5.111.2NodeprvtCESConformance
1.3.6.1.4.1.738.1.5.111.2.1NodeprvtCESDsx1Compliances
1.3.6.1.4.1.738.1.5.111.2.1.1ComplianceprvtCESDsx1CompliancecurrentThe compliance statement for management of TDM ports.
1.3.6.1.4.1.738.1.5.111.2.2NodeprvtCESDsx1Groups
1.3.6.1.4.1.738.1.5.111.2.2.1GroupprvtCESDsx1NotificationsGroupcurrentThe group of supported notifications.
1.3.6.1.4.1.738.1.5.111.2.2.2GroupprvtCESDsx1ROGroupread-writecurrentThe group of objects with MAX-ACCESS read-write supported with read-only access for the first release.
Type Definitions
NameSyntaxStatusDescription
CESLineTypeINTEGER { e1(1), t1(2), e1-sdh(3), t1-sdh(4), t1-sonet(5) }currentThis value is used to configure the line mode common for all TDM ports of the module.
ConfigActionINTEGER { noop(1), applyConfiguration(2), rejectConfiguration(3), restart(4) }currentThis value is used to specify what is to be done with unapplied CES module configuration.
E1ImpedanceINTEGER { notApplicable(0), e1-75ohm(1), e1-75hrl(2), e1-120ohm(3), e1-120hrl(4) }currentThis value is used to configure E1 line type termination impedance.
ServiceClockINTEGER{ notAplicable(0), loopTiming (1), localTiming (2), adaptive (3), differntial (4) }currentThis values are used to configure transmit clock as one of this modes.
T1GainLimitINTEGER { notApplicable(0), none(1), gain30(2), gain36(3) }currentThis value is used to configure T1 type Tx or Rx gain limit.
T1LongCableLengthINTEGER { notApplicable (1), neg75dB (2), neg15dB (3), neg225dB (4), zerodB (5) }currentThis value is used to configure T1 long cable length.