RAINBOW-NOTIFICATIONS-MIB
80 objects
Rainbow notifications MIB Definitions
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.12394.1.2.0 | IdentityrbNotifications | Rainbow notifications MIB Definitions | ||
| 1.3.6.1.4.1.12394.1.2.0.1 | NotificationrbResetOn | current | This trap is sent when the device/card is going to perform reset. rbTrapSource = NPU/AU/SU rbTrapSeverity = Info rbTrapCategory = Equipment rbTrapAdditionalInf… | |
| 1.3.6.1.4.1.12394.1.2.0.2 | NotificationrbDiagnosticsHwFaultOn | current | Device/card has detected hardware fault. rbTrapSource = NPU/AU/SU rbTrapSeverity = Major rbTrapCategory = Equipment rbTrapAdditionalInfo = 3..8,23..27. | |
| 1.3.6.1.4.1.12394.1.2.0.3 | NotificationrbDiagnosticsHwFaultOff | current | Previously detected hardware fault is fixed. rbTrapSource = NPU/AU/SU rbTrapSeverity = Info rbTrapCategory = Equipment rbTrapAdditionalInfo = 3..8,23..27. | |
| 1.3.6.1.4.1.12394.1.2.0.4 | NotificationrbMonitorAccessOn | current | Device is accessed via LCI or Telnet. rbTrapSource = NPU/SU rbTrapSeverity = Info, rbTrapCategory = Equipment, rbTrapAdditionalInfo = 140,141, rbTrapIpAddress | |
| 1.3.6.1.4.1.12394.1.2.0.5 | NotificationrbMonitorAccessOff | current | LCI or Telnet access was terminated rbTrapSource = NPU/SU rbTrapSeverity = Info, rbTrapCategory = Equipment, rbTrapAdditionalInfo = 140,141, rbTrapIpAddress | |
| 1.3.6.1.4.1.12394.1.2.0.6 | NotificationrbAuNetworkEntryStatus | current | AU Network Entry status changed rbTrapSource = AU rbTrapSeverity = Info, rbTrapCategory = Communication, rbTrapAdditionalInfo = 135-139 | |
| 1.3.6.1.4.1.12394.1.2.0.7 | NotificationrbModeConflictOn | current | AU/SU mode conflict was detected rbTrapSource = AU/SU rbTrapSeverity = Major, rbTrapCategory = Communication, rbTrapAdditionalInfo = 144 .. 149. | |
| 1.3.6.1.4.1.12394.1.2.0.8 | NotificationrbModeConflictOff | current | AU/SU mode conflict terminated rbTrapSource = AU/SU rbTrapSeverity = Info, rbTrapCategory = Communication, rbTrapAdditionalInfo = 144. | |
| 1.3.6.1.4.1.12394.1.2.0.21 | NotificationrbShelfCardExtractionOn | current | Card is extracted from the shelf. rbTrapSource = NPU/AU/PSU/PIU/ACU rbTrapSeverity = Info, rbTrapCategory = Equipment | |
| 1.3.6.1.4.1.12394.1.2.0.22 | NotificationrbShelfCardInsertionOn | current | Card is inserted in the shelf. rbTrapSource = NPU/AU/PSU/PIU/ACU rbTrapSeverity = Info, rbTrapCategory = Equipment | |
| 1.3.6.1.4.1.12394.1.2.0.23 | NotificationrbShelfPeripheralEquipmentFaultOn | current | Fault is detected in one of the Shelf Peripheral Equipment Units. rbTrapSource = PSU#/PIU#/ACU#/ACU-FAN#/AU rbTrapSeverity = Minor, rbTrapCategory = Equipment … | |
| 1.3.6.1.4.1.12394.1.2.0.24 | NotificationrbShelfPeripherallEquipmentFaultOff | current | Previously detected fault in one of the shelf Peripheral Equipment Units is terminated. rbTrapSource = PSU#/PIU#/ACU#/AU rbTrapSeverity = Info, rbTrapCategory … | |
| 1.3.6.1.4.1.12394.1.2.0.25 | NotificationrbShelfEnvParamFaultOn | current | Fault is detected in the shelf environment parameter. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 73..76 | |
| 1.3.6.1.4.1.12394.1.2.0.26 | NotificationrbShelfEnvParamFaultOff | current | Previously detected environment parameter fault is terminated. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 73..… | |
| 1.3.6.1.4.1.12394.1.2.0.41 | NotificationrbConfigurationChanged | current | Configuration change was detected, rbTrapSource = NPU/AU/SU/RC/ODU/CHNL/SBSCR/SRVC rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapAdditionalInfo = 30.… | |
| 1.3.6.1.4.1.12394.1.2.0.42 | NotificationrbParameterSetFailure | current | Configuration change was detected, rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = Equipment rbTrapSetFailureReason. | |
| 1.3.6.1.4.1.12394.1.2.0.50 | NotificationrbMbstLicense | current | License Grace Period expiration warning, rbTrapSource = MicroBST rbTrapSeverity = Info, rbTrapCategory = Proc, rbTrapAdditionalInfo = 184,185. | |
| 1.3.6.1.4.1.12394.1.2.0.51 | NotificationrbMbstCPEQuantityExceed | current | Allowed quantity of CPEs exceeded in the actual Mbst, rbTrapSource = MicroBST rbTrapSeverity = Info, rbTrapCategory = Proc, rbSuMacAddr = Rejected SU Mac | |
| 1.3.6.1.4.1.12394.1.2.0.52 | NotificationrbLicenseFileLoadStatus | current | License File Load process status, rbTrapSource = NPU/MicroBST rbTrapSeverity = Info, rbTrapCategory = Proc, rbTrapAdditionalInfo = 187..191 | |
| 1.3.6.1.4.1.12394.1.2.0.61 | NotificationrbOduCrcErrorOn | obsolete | Obsolete from release 2.5 CRC error in the ODU table was detected, rbTrapSource = AU rbTrapSeverity = Warning, rbTrapCategory = Communication, rbChannelId = nu… | |
| 1.3.6.1.4.1.12394.1.2.0.62 | NotificationrbOduCrcErrorOff | obsolete | Obsolete from release 2.5 Previously detected CRC error in ODU table terminated, rbTrapSource = AU rbTrapSeverity = Info, rbTrapCategory = Communication, rbCha… | |
| 1.3.6.1.4.1.12394.1.2.0.63 | NotificationrbOduCommErrorOn | current | Error in the communication with the ODU unit was detected, rbTrapSource = AU rbTrapSeverity = Minor, rbTrapCategory = Communication, rbChannelId = number of ch… | |
| 1.3.6.1.4.1.12394.1.2.0.64 | NotificationrbOduCommErrorOff | current | Previously detected ODU communication error terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of chann… | |
| 1.3.6.1.4.1.12394.1.2.0.65 | NotificationrbOduBandMissmatchOn | current | Actual ODU Band does not match configured ODU Band, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Communication, rbChannelId = number of channel | |
| 1.3.6.1.4.1.12394.1.2.0.66 | NotificationrbOduBandMissmatchOff | current | Previously detected ODU Band mismatch terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel | |
| 1.3.6.1.4.1.12394.1.2.0.67 | NotificationrbOduPowerMismatch | current | Actual ODU Max/Min Tx power does not match configured ODU Max/Min Tx power, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannel… | |
| 1.3.6.1.4.1.12394.1.2.0.68 | NotificationrbOduFailureOn | current | ODU unit failure was detected, rbTrapSource = AU rbTrapSeverity = Major, rbTrapCategory = Communication, rbChannelId = number of channel, rbTrapAdditionalInfo … | |
| 1.3.6.1.4.1.12394.1.2.0.69 | NotificationrbOduFailureOff | current | Previously detected ODU failure terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Communication, rbChannelId = number of channel | |
| 1.3.6.1.4.1.12394.1.2.0.81 | NotificationrbSuMaxTxPowerReached | current | SU reached the maximum allowed output power, rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.82 | NotificationrbSuMinTxPowerReached | current | SU reached the minimum allowed output power rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.83 | NotificationrbSuNetworkEntryStatus | current | Status of the SU's network entry. rbTrapSource = SU, rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 132-134 | |
| 1.3.6.1.4.1.12394.1.2.0.84 | NotificationrbSuLicense | current | License Grace Period expiration warning, rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = Proc, rbTrapAdditionalInfo = 182-186, rbLicenseId = Type of … | |
| 1.3.6.1.4.1.12394.1.2.0.85 | NotificationrbSuDuplicateName | current | The SU Name is already in use by another SU. Services to the SU will be denied until another, unique name is configured for the SU. rbTrapSource = SU, rbTrapSe… | |
| 1.3.6.1.4.1.12394.1.2.0.101 | NotificationrbSwDownloadStart | current | Software download process is started. rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.102 | NotificationrbSwDownloadEnd | current | Software download process is finished rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.103 | NotificationrbSwDownloadError | current | Software download process error. rbTrapSource = NPU/AU/SU rbTrapSeverity = Minor, rbTrapCategory = PROC rbTrapAdditionalInfo =100..103 | |
| 1.3.6.1.4.1.12394.1.2.0.104 | NotificationrbSwSwitchFailed | current | Software switch over failed. rbTrapSource = NPU/AU/SU rbTrapSeverity = Minor, rbTrapCategory = PROC, rbTrapAdditionalInfo = 104..105 | |
| 1.3.6.1.4.1.12394.1.2.0.105 | NotificationrbSwSwitchSucceed | current | Software switch over succeeded , rbTrapSource = NPU/AU/SU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = | |
| 1.3.6.1.4.1.12394.1.2.0.106 | NotificationrbBERTestFinished | current | BER Test is finished , rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.107 | NotificationrbBERTestStarted | current | BER Test is started , rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.108 | NotificationrbSwFileConflict | current | AU configured SW file and AU HW mismatch, rbTrapSource = AU/SU rbTrapSeverity = Minor, rbTrapCategory = PROC | |
| 1.3.6.1.4.1.12394.1.2.0.109 | NotificationrbXMLDownloadResult | current | XML File Download status. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 220..224 | |
| 1.3.6.1.4.1.12394.1.2.0.110 | NotificationrbFreqBandDownloadResult | current | Frequency Band File Download status. rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 220..222,224 | |
| 1.3.6.1.4.1.12394.1.2.0.111 | NotificationrbServiceDown | current | The Service is down or didn't start, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = QoS | |
| 1.3.6.1.4.1.12394.1.2.0.112 | NotificationrbServiceUp | current | The Service is operational, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = QoS | |
| 1.3.6.1.4.1.12394.1.2.0.113 | NotificationrbServiceChanged | current | The Service was modified, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = QoS, rbTrapAdditionalInfo = 119..122 | |
| 1.3.6.1.4.1.12394.1.2.0.114 | NotificationrbServiceGeneralError | current | Service error was detected, rbTrapSource = NPU, rbTrapSeverity = Minor, rbTrapCategory = QoS rbTrapAdditionalInfo =111..118. | |
| 1.3.6.1.4.1.12394.1.2.0.115 | NotificationrbNetworkingError | current | Loop was detected on SU Ethernet port, rbTrapSource = SU rbTrapSeverity = Info, rbTrapCategory = PROC, rbTrapAdditionalInfo = 10.. | |
| 1.3.6.1.4.1.12394.1.2.0.117 | NotificationrbSwitchedAuthenticationServer | current | RADIUS Client switched to another Authentication Server, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM | |
| 1.3.6.1.4.1.12394.1.2.0.118 | NotificationrbSwitchedAccountingServer | current | RADIUS Client switched to another Accounting Server, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM | |
| 1.3.6.1.4.1.12394.1.2.0.119 | NotificationrbServiceEstablishmentFailure | current | Service establishment failure, rbTrapSource = NPU, rbTrapSeverity = Minor, rbTrapCategory = QoS rbTrapAdditionalInfo = 200 .. 210, 214 rbServiceIdx = Service P… | |
| 1.3.6.1.4.1.12394.1.2.0.120 | NotificationrbUserAuthenticationTimeout | current | User authentication timeout, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM, rbTrapAdditionalInfo = 211 .. 213, rbSuMacAddr = SU MAC. | |
| 1.3.6.1.4.1.12394.1.2.0.121 | NotificationrbUserAuthenticationReject | current | User authentication rejected, rbTrapSource = NPU rbTrapSeverity = Info, rbTrapCategory = COMM, rbSuMacAddr = SU MAC. | |
| 1.3.6.1.4.1.12394.1.2.0.122 | NotificationrbAuthenticationServerKeepAliveTimeoutOn | current | Authentication Server Keep Alive Timeout was detected, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment, rbRadiusAuthServerAddress = Serv… | |
| 1.3.6.1.4.1.12394.1.2.0.123 | NotificationrbAuthenticationServerKeepAliveTimeoutOff | current | Previously detected Authentication Server Keep Alive Timeout terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment, rbRadiusAuthSer… | |
| 1.3.6.1.4.1.12394.1.2.0.124 | NotificationrbAccountingServerKeepAliveTimeoutOn | current | Accounting Server Keep Alive Timeout was detected, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment, rbRadiusAcctServerAddress = Server I… | |
| 1.3.6.1.4.1.12394.1.2.0.125 | NotificationrbAccountingServerKeepAliveTimeoutOff | current | Previously detected Accounting Server Keep Alive Timeout terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment, rbRadiusAcctServerA… | |
| 1.3.6.1.4.1.12394.1.2.0.134 | NotificationrbExternal1PPSFailureOn | current | External 1PPS failure was detected. BS will produce this alarm only if external 1PPS clock is enabled, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCatego… | |
| 1.3.6.1.4.1.12394.1.2.0.135 | NotificationrbExternal1PPSFailureOff | current | Previously detected External 1PPS failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.136 | NotificationrbInternal1PPSFailureOn | current | Internal NPU 1PPS failure was detected, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.137 | NotificationrbInternal1PPSFailureOff | current | Internal NPU 1PPS failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.138 | NotificationrbExternal16MHzFailureOn | current | External 16MHz failure was detected. BS will produce this alarm only if external 16MHz clock is enabled, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCate… | |
| 1.3.6.1.4.1.12394.1.2.0.139 | NotificationrbExternal16MHzFailureOff | current | External 16MHz failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.140 | NotificationrbInternal16MHzFailureOn | current | Internal NPU 16MHz failure was detected. Can be produced by all types of BSs, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.141 | NotificationrbInternal16MHzFailureOff | current | Internal NPU 16MHz failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.142 | NotificationrbGPSComFailureOn | current | GPS Com failure was detected. Can be produced only if GPS type is Trimble, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.143 | NotificationrbGPSComFailureOff | current | GPS Com failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.144 | NotificationrbGPSHealthyFailureOn | current | GPS Healthy failure was detected. Can be produced only if GPS type is Trimble, rbTrapSource = NPU, rbTrapSeverity = Major, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.145 | NotificationrbGPSHealthyFailureOff | current | GPS Healthy failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.146 | NotificationrbMin4SatSyncFailureOn | current | Min4SatSync failure was detected. This indicated that less than four satellites are received by the GPS. Can be produced only if GPS type is Trimble, rbTrapSou… | |
| 1.3.6.1.4.1.12394.1.2.0.147 | NotificationrbMin4SatSyncFailureOff | current | Min4SatSync failure terminated, rbTrapSource = NPU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.148 | NotificationrbAUExternal1PPSFailureOn | current | External 1PPS failure was detected. Can be produced by AU when the selected 1PPS arriving from active NPU is failed, rbTrapSource = AU, rbTrapSeverity = Major,… | |
| 1.3.6.1.4.1.12394.1.2.0.149 | NotificationrbAUExternal1PPSFailureOff | current | External 1PPS failure terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.150 | NotificationrbAUHoldOverEnteredOn | current | HoldOver Entered was detected. Can be produced by AU when the AU goes to holdover, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.151 | NotificationrbAUHoldOverEnteredOff | current | HoldOver Entered terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.152 | NotificationrbAUHoldOverTimeoutPassedOn | current | HoldOver passed was detected. Can be produced by AU when the AU holdover passed the Timeout, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipm… | |
| 1.3.6.1.4.1.12394.1.2.0.153 | NotificationrbAUHoldOverTimeoutPassedOff | current | HoldOver passed terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.154 | NotificationrbAUHoldOverTxStoppedOn | current | HoldOver passed and Stop TX operation was detected, rbTrapSource = AU, rbTrapSeverity = Major, rbTrapCategory = Equipment. | |
| 1.3.6.1.4.1.12394.1.2.0.155 | NotificationrbAUHoldOverTxStoppedOff | current | Stop TX operation terminated, rbTrapSource = AU, rbTrapSeverity = Info, rbTrapCategory = Equipment. |