RC-2K-MIB

353 objects
Enterprise MIB for the rc2k.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2272.1.100.0Identityrc2kMibread-writeEnterprise MIB for the rc2k.
1.3.6.1.4.1.2272.1.100.1Noderc2kChassis
1.3.6.1.4.1.2272.1.100.1.1Scalarrc2kChassisPortOperStatusread-onlycurrentA bit array that contains the oper-status of the ports in the device. 2 bits are used for each port. The high order 2 bits of the first octet represent port #0…
1.3.6.1.4.1.2272.1.100.1.2Scalarrc2kChassisTemperatureread-onlycurrentUsed to indicate the core operating temperature of the chassis. This value represents the degree in celsius of the air inside the chassis.
1.3.6.1.4.1.2272.1.100.1.3Scalarrc2kChassisAmbientLowerTemperatureread-onlyobsoleteUsed to indicate the temperature of the air entering the fan at the lower half of the chassis.
1.3.6.1.4.1.2272.1.100.1.4Scalarrc2kChassisAmbientUpperTemperatureread-onlyobsoleteUsed to indicate the temperature of the air entering the fan at the upper half of the chassis.
1.3.6.1.4.1.2272.1.100.1.5Scalarrc2kChassisBaseMacAddrread-onlycurrentbase mac addr
1.3.6.1.4.1.2272.1.100.1.6Scalarrc2kChassisMacAddrCapacityread-onlycurrentMac Address Capacity
1.3.6.1.4.1.2272.1.100.1.7Scalarrc2kChassisPbtMacAddrread-onlycurrentpbt mac addr
1.3.6.1.4.1.2272.1.100.1.8Scalarrc2kChassisUserLabel1read-writecurrentuser defined management information. This can be used to provide extra information about the chassis. Syntax can be as expected by the management system
1.3.6.1.4.1.2272.1.100.1.9Scalarrc2kChassisPbtMacAddrListread-onlycurrentList of 8 Pbt Mac addresses. The first Pbt Mac Address is rc2kChassisPbtMacAddr. The other 7 Pbt Mac Addresses are derived by increment 1 to the previous mac s…
1.3.6.1.4.1.2272.1.100.1.10Scalarrc2kChassisSystemTempLedColorread-onlycurrentUsed to indicate the led color of the system temperature which is under or above the threshold. The threshold is 60 degree in celsius. 'green' means normal. An…
1.3.6.1.4.1.2272.1.100.1.11Scalarrc2kChassisPortLedStatusread-onlycurrentThis is applicable only for VSP4K. Max port 3/64 A bit array that contains the LED status of the ports in the device. 1 octet is used for each port. Starting a…
1.3.6.1.4.1.2272.1.100.1.12Scalarrc2kChassisPortLed2Statusread-onlycurrentThis is applicable only for VSP8200, VSP8400 & VSP8600. Each octet string contains the value of a port LED status. One octet is used for each port. Each octet …
1.3.6.1.4.1.2272.1.100.1.13Scalarrc2kChassisPortLicenseStatusread-onlycurrentThis is applicable only for VSP7K. The string is 56 octets long, for a total of 448 bits. Each bit corresponds to a port, as represented by its ifIndex value. …
1.3.6.1.4.1.2272.1.100.1.14Scalarrc2kChassisPortLed3Statusread-onlycurrentThis is applicable only for Tomahawk 100G port, DSG9032, DSG8064, T3x032(with 32 100G ports), T3x048v(with 48 25G ports plus 8 100G ports) and VSP4900. For DSG…
1.3.6.1.4.1.2272.1.100.2Tablerc2kCpuEthernetPortTablenot-accessiblecurrent2k CPU Ethernet Port table
1.3.6.1.4.1.2272.1.100.2.1Rowrc2kCpuEthernetPortEntrynot-accessiblecurrentEntry containing infomation of 2k CPU Ethernet Port
1.3.6.1.4.1.2272.1.100.2.1.1Columnrc2kCpuEthernetPortIfIndexread-onlycurrentIfIndex of the port.
1.3.6.1.4.1.2272.1.100.2.1.2Columnrc2kCpuEthernetPortDescrread-onlycurrentPort description
1.3.6.1.4.1.2272.1.100.2.1.3Columnrc2kCpuEthernetPortAdminStatusread-writecurrentUsed to configure the admininstrative status of the port.
1.3.6.1.4.1.2272.1.100.2.1.4Columnrc2kCpuEthernetPortOperStatusread-onlycurrentUsed to indicate the administrative status of the port.
1.3.6.1.4.1.2272.1.100.2.1.5Columnrc2kCpuEthernetPortAddrread-writecurrentUsed to configure the port's IP address
1.3.6.1.4.1.2272.1.100.2.1.6Columnrc2kCpuEthernetPortMaskread-writecurrentUsed to configure the port's net mask
1.3.6.1.4.1.2272.1.100.2.1.7Columnrc2kCpuEthernetPortGatewayread-writecurrentUsed to configure the the IP address of the gateway that should be used to forward IP traffic.
1.3.6.1.4.1.2272.1.100.2.1.8Columnrc2kCpuEthernetPortNetworkread-writecurrentUsed to configure the network that can be used to remotely manage this device.
1.3.6.1.4.1.2272.1.100.2.1.9Columnrc2kCpuEthernetPortAutoNegotiateread-writecurrentUsed to configure auto-negotiation on this port.
1.3.6.1.4.1.2272.1.100.2.1.10Columnrc2kCpuEthernetPortAdminDuplexread-writecurrentUsed to configure the administrative duplex setting for this port.
1.3.6.1.4.1.2272.1.100.2.1.11Columnrc2kCpuEthernetPortOperDuplexread-onlycurrentUsed to indicate the operational duplex setting for this port.
1.3.6.1.4.1.2272.1.100.2.1.12Columnrc2kCpuEthernetPortAdminSpeedread-writecurrentUsed to configure the administrative speed setting for this port.
1.3.6.1.4.1.2272.1.100.2.1.13Columnrc2kCpuEthernetPortOperSpeedread-onlycurrentUsed to indicate the operational duplex setting for this port.
1.3.6.1.4.1.2272.1.100.2.1.14Columnrc2kCpuEthernetPortEnableBootpread-writecurrentUsed to enable/disable the Bootp feature on this port.
1.3.6.1.4.1.2272.1.100.2.1.15Columnrc2kCpuEthernetPortMgmtMacAddrread-onlycurrentUsed to indicate the mac addr for this port.
1.3.6.1.4.1.2272.1.100.3Tablerc2kCpuSerialPortTablenot-accessiblecurrent2k CPU Serial Port table
1.3.6.1.4.1.2272.1.100.3.1Rowrc2kCpuSerialPortEntrynot-accessiblecurrentEntry containing infomation of 2k CPU Serial Port
1.3.6.1.4.1.2272.1.100.3.1.1Columnrc2kCpuSerialPortIfIndexread-onlycurrentIfIndex for this port.
1.3.6.1.4.1.2272.1.100.3.1.2Columnrc2kCpuSerialPortDescrread-onlycurrentPort description.
1.3.6.1.4.1.2272.1.100.3.1.3Columnrc2kCpuSerialPortModeread-writecurrentUsed to configure the mode this port should operate in.
1.3.6.1.4.1.2272.1.100.3.1.4Columnrc2kCpuSerialPortAdminStatusread-writecurrentUsed to configure the administrative status setting for this port.
1.3.6.1.4.1.2272.1.100.3.1.5Columnrc2kCpuSerialPortOperStatusread-onlycurrentUsed to indicate the operational status setting for this port.
1.3.6.1.4.1.2272.1.100.3.1.6Columnrc2kCpuSerialPortBaudRateread-writecurrentUsed to configure the baud rate of this port.
1.3.6.1.4.1.2272.1.100.3.1.7Columnrc2kCpuSerialPortDataBitsread-writecurrentUsed to configure the number of data bits, per byte of data, this port should send/receive.
1.3.6.1.4.1.2272.1.100.3.1.8Columnrc2kCpuSerialPortMyAddrread-writecurrentUsed to configure this port's IP address. Used for both 'slip' and 'ppp' modes.
1.3.6.1.4.1.2272.1.100.3.1.9Columnrc2kCpuSerialPortPeerAddrread-writecurrentUsed to configure the peer's IP address. Used for both 'slip' and 'ppp' modes.
1.3.6.1.4.1.2272.1.100.3.1.10Columnrc2kCpuSerialPortSlipMturead-writecurrentUsed to configure the MTU for this port. Used for slip only.
1.3.6.1.4.1.2272.1.100.3.1.11Columnrc2kCpuSerialPortSlipTxRxCompressread-writecurrentUsed to enable/disable compression of TCP/IP packet headers on this port. Used for slip only.
1.3.6.1.4.1.2272.1.100.3.1.12Columnrc2kCpuSerialPortSlipRxCompressread-writecurrentUsed to enable/disable compression for receiving packets on this port. Used for slip only.
1.3.6.1.4.1.2272.1.100.3.1.13Columnrc2kCpuSerialPortPppConfigFileread-writecurrentUsed to configure the configuration file to use for PPP.
1.3.6.1.4.1.2272.1.100.4Noderc2kDevice
1.3.6.1.4.1.2272.1.100.4.1Tablerc2kDeviceGlobalTablenot-accessiblecurrent2k CPU Ethernet Port table
1.3.6.1.4.1.2272.1.100.4.1.1Rowrc2kDeviceGlobalEntrynot-accessiblecurrentEntry containing infomation of 2k CPU Ethernet Port
1.3.6.1.4.1.2272.1.100.4.1.1.1Columnrc2kDeviceGlobalSlotread-onlycurrentslot number
1.3.6.1.4.1.2272.1.100.4.1.1.2Columnrc2kDeviceGlobalFlashBytesUsedread-onlycurrentbytes used
1.3.6.1.4.1.2272.1.100.4.1.1.3Columnrc2kDeviceGlobalFlashBytesFreeread-onlycurrentbytes free
1.3.6.1.4.1.2272.1.100.4.1.1.4Columnrc2kDeviceGlobalFlashNumFilesread-onlycurrent# files in flash
1.3.6.1.4.1.2272.1.100.4.1.1.5Columnrc2kDeviceGlobalPcmciaBytesUsedread-onlycurrentbytes used
1.3.6.1.4.1.2272.1.100.4.1.1.6Columnrc2kDeviceGlobalPcmciaBytesFreeread-onlycurrentbytes free
1.3.6.1.4.1.2272.1.100.4.1.1.7Columnrc2kDeviceGlobalPcmciaNumFilesread-onlycurrent# files in pcmcia
1.3.6.1.4.1.2272.1.100.4.1.1.8Columnrc2kDeviceGlobalActionread-writecurrentnone(1), resetPcmcia(2), ..
1.3.6.1.4.1.2272.1.100.4.1.1.9Columnrc2kDeviceGlobalResultread-onlycurrentUsed to indicate the result of the last action performed on one of the system's device.
1.3.6.1.4.1.2272.1.100.4.1.1.10Columnrc2kDeviceGlobalFlash1BytesUsedread-onlycurrentbytes used
1.3.6.1.4.1.2272.1.100.4.1.1.11Columnrc2kDeviceGlobalFlash1BytesFreeread-onlycurrentbytes free
1.3.6.1.4.1.2272.1.100.4.1.1.12Columnrc2kDeviceGlobalFlash1NumFilesread-onlycurrent# files in flash
1.3.6.1.4.1.2272.1.100.4.1.1.13Columnrc2kDeviceGlobalUsbBytesUsedread-onlycurrentbytes used in USB
1.3.6.1.4.1.2272.1.100.4.1.1.14Columnrc2kDeviceGlobalUsbBytesFreeread-onlycurrentbytes free in USB
1.3.6.1.4.1.2272.1.100.4.1.1.15Columnrc2kDeviceGlobalUsbNumFilesread-onlycurrent# files in USB
1.3.6.1.4.1.2272.1.100.4.1.1.16Columnrc2kDeviceGlobalExtflashBytesUsedread-onlycurrentbytes used in Extflash
1.3.6.1.4.1.2272.1.100.4.1.1.17Columnrc2kDeviceGlobalExtflashBytesFreeread-onlycurrentbytes free in Extflash
1.3.6.1.4.1.2272.1.100.4.1.1.18Columnrc2kDeviceGlobalExtflashNumFilesread-onlycurrent# files in Extflash
1.3.6.1.4.1.2272.1.100.4.1.1.19Columnrc2kDeviceGlobalIntflashBytesUsedread-onlycurrentbytes used in intflash. It is used to replace rc2kDeviceGlobalFlashBytesUsed
1.3.6.1.4.1.2272.1.100.4.1.1.20Columnrc2kDeviceGlobalIntflashBytesFreeread-onlycurrentbytes free in intflash. It is used to replace rc2kDeviceGlobalFlashByteFree
1.3.6.1.4.1.2272.1.100.4.2Scalarrc2kDeviceSeparator1read-onlycurrentThis leaf is used to provide a separation between tables. No meaningful information is stored in this variable.
1.3.6.1.4.1.2272.1.100.4.3Tablerc2kDeviceFlashFileTablenot-accessiblecurrent2k Flash table
1.3.6.1.4.1.2272.1.100.4.3.1Rowrc2kDeviceFlashFileEntrynot-accessiblecurrentEntry containing infomation of 2k CPU Serial Port
1.3.6.1.4.1.2272.1.100.4.3.1.1Columnrc2kDeviceFlashFileSlotread-onlycurrentslot number
1.3.6.1.4.1.2272.1.100.4.3.1.2Columnrc2kDeviceFlashFileNameread-onlycurrentname of file
1.3.6.1.4.1.2272.1.100.4.3.1.3Columnrc2kDeviceFlashFileDateread-onlycurrentdate
1.3.6.1.4.1.2272.1.100.4.3.1.4Columnrc2kDeviceFlashFileSizeread-onlycurrentsize in bytes
1.3.6.1.4.1.2272.1.100.4.4Scalarrc2kDevicePcmciaPresentread-onlycurrentpcmcia is a slower device. This leaf is used to stop the access into pcmcia file table when it got the end of flash file table.
1.3.6.1.4.1.2272.1.100.4.5Tablerc2kDevicePcmciaFileTablenot-accessiblecurrent2k PCMCIA table
1.3.6.1.4.1.2272.1.100.4.5.1Rowrc2kDevicePcmciaFileEntrynot-accessiblecurrentEntry containing infomation of 2k CPU Serial Port
1.3.6.1.4.1.2272.1.100.4.5.1.1Columnrc2kDevicePcmciaFileSlotread-onlycurrentslot number
1.3.6.1.4.1.2272.1.100.4.5.1.2Columnrc2kDevicePcmciaFileNameread-onlycurrentname of file
1.3.6.1.4.1.2272.1.100.4.5.1.3Columnrc2kDevicePcmciaFileDateread-onlycurrentdate
1.3.6.1.4.1.2272.1.100.4.5.1.4Columnrc2kDevicePcmciaFileSizeread-onlycurrentsize in bytes
1.3.6.1.4.1.2272.1.100.4.6Scalarrc2kDeviceSeparator2read-onlycurrentThis leaf is used to provide a separation between tables. No meaningful information is stored in this variable.
1.3.6.1.4.1.2272.1.100.4.7Scalarrc2kDeviceFlash1Presentread-onlycurrentThis leaf is used to stop the access into Flash1 file table.
1.3.6.1.4.1.2272.1.100.4.8Tablerc2kDeviceFlash1FileTablenot-accessiblecurrent2k Flash1 table
1.3.6.1.4.1.2272.1.100.4.8.1Rowrc2kDeviceFlash1FileEntrynot-accessiblecurrentEntry containing infomation of 2k Flash1 Files
1.3.6.1.4.1.2272.1.100.4.8.1.1Columnrc2kDeviceFlash1FileSlotread-onlycurrentslot number
1.3.6.1.4.1.2272.1.100.4.8.1.2Columnrc2kDeviceFlash1FileNameread-onlycurrentname of file
1.3.6.1.4.1.2272.1.100.4.8.1.3Columnrc2kDeviceFlash1FileDateread-onlycurrentdate
1.3.6.1.4.1.2272.1.100.4.8.1.4Columnrc2kDeviceFlash1FileSizeread-onlycurrentsize in bytes
1.3.6.1.4.1.2272.1.100.4.9Tablerc2kDeviceExtflashFileTablenot-accessiblecurrent2k Flash table
1.3.6.1.4.1.2272.1.100.4.9.1Rowrc2kDeviceExtflashFileEntrynot-accessiblecurrentEntry containing information of extflash files
1.3.6.1.4.1.2272.1.100.4.9.1.1Columnrc2kDeviceExtflashFileSlotnot-accessiblecurrentslot number
1.3.6.1.4.1.2272.1.100.4.9.1.2Columnrc2kDeviceExtflashFileNamenot-accessiblecurrentname of file
1.3.6.1.4.1.2272.1.100.4.9.1.3Columnrc2kDeviceExtflashFileDateread-onlycurrentdate
1.3.6.1.4.1.2272.1.100.4.9.1.4Columnrc2kDeviceExtflashFileSizeread-onlycurrentsize in bytes
1.3.6.1.4.1.2272.1.100.4.10Tablerc2kDeviceUsbFileTablenot-accessiblecurrent2k Usb table
1.3.6.1.4.1.2272.1.100.4.10.1Rowrc2kDeviceUsbFileEntrynot-accessiblecurrentEntry containing information of USB files
1.3.6.1.4.1.2272.1.100.4.10.1.1Columnrc2kDeviceUsbFileSlotnot-accessiblecurrentslot number
1.3.6.1.4.1.2272.1.100.4.10.1.2Columnrc2kDeviceUsbFileNamenot-accessiblecurrentname of file
1.3.6.1.4.1.2272.1.100.4.10.1.3Columnrc2kDeviceUsbFileDateread-onlycurrentdate
1.3.6.1.4.1.2272.1.100.4.10.1.4Columnrc2kDeviceUsbFileSizeread-onlycurrentsize in bytes
1.3.6.1.4.1.2272.1.100.5Tablerc2kBootConfigTablenot-accessiblecurrent2k Boot Configuration table
1.3.6.1.4.1.2272.1.100.5.1Rowrc2kBootConfigEntrynot-accessiblecurrentEntry containing boot configuration information.
1.3.6.1.4.1.2272.1.100.5.1.1Columnrc2kBootConfigSlotread-onlycurrentslot number, tattoo use 3 as cpu slot, 4 & 7-10 are not valid cpu slot number, VSP uses slots 1 and 2 for cpu slot
1.3.6.1.4.1.2272.1.100.5.1.2Columnrc2kBootConfigLastBootConfigSourceread-onlycurrentboot config source
1.3.6.1.4.1.2272.1.100.5.1.3Columnrc2kBootConfigLastRuntimeImageSourceread-onlycurrentruntime image source
1.3.6.1.4.1.2272.1.100.5.1.4Columnrc2kBootConfigLastRuntimeConfigSourceread-onlycurrentruntime config source
1.3.6.1.4.1.2272.1.100.5.1.5Columnrc2kBootConfigPrimaryImageSourceread-writecurrentimage source
1.3.6.1.4.1.2272.1.100.5.1.6Columnrc2kBootConfigPrimaryConfigSourceread-writecurrentconfig source
1.3.6.1.4.1.2272.1.100.5.1.7Columnrc2kBootConfigSecondaryImageSourceread-writecurrentimage source
1.3.6.1.4.1.2272.1.100.5.1.8Columnrc2kBootConfigSecondaryConfigSourceread-writecurrentconfig source
1.3.6.1.4.1.2272.1.100.5.1.9Columnrc2kBootConfigTertiaryImageSourceread-writecurrentimage source
1.3.6.1.4.1.2272.1.100.5.1.10Columnrc2kBootConfigTertiaryConfigSourceread-writecurrentconfig source
1.3.6.1.4.1.2272.1.100.5.1.11Columnrc2kBootConfigEnableAutoBootread-writecurrentauto boot mode
1.3.6.1.4.1.2272.1.100.5.1.12Columnrc2kBootConfigEnableFactoryDefaultsread-writecurrentuse factory default
1.3.6.1.4.1.2272.1.100.5.1.13Columnrc2kBootConfigEnableDebugModeread-writecurrentdebug mode
1.3.6.1.4.1.2272.1.100.5.1.14Columnrc2kBootConfigEnableHwWatchDogTimerread-writecurrenthw watch dog timer
1.3.6.1.4.1.2272.1.100.5.1.15Columnrc2kBootConfigEnableRebootOnErrorread-writecurrentreboot on error
1.3.6.1.4.1.2272.1.100.5.1.16Columnrc2kBootConfigEnableTelnetServerread-writecurrenttelnet server
1.3.6.1.4.1.2272.1.100.5.1.17Columnrc2kBootConfigEnableRloginServerread-writecurrentrlogin server
1.3.6.1.4.1.2272.1.100.5.1.18Columnrc2kBootConfigEnableFtpServerread-writecurrentftp server
1.3.6.1.4.1.2272.1.100.5.1.19Columnrc2kBootConfigEnableTftpServerread-writecurrenttftp server
1.3.6.1.4.1.2272.1.100.5.1.20Columnrc2kBootConfigSwVersionread-onlycurrentcurrent sw version
1.3.6.1.4.1.2272.1.100.5.1.21Columnrc2kBootConfigMulticastConfigProfileread-onlycurrentmulticast config
1.3.6.1.4.1.2272.1.100.5.1.22Columnrc2kBootConfigEnableSshServerread-writecurrentssh server
1.3.6.1.4.1.2272.1.100.5.1.23Columnrc2kBootConfigEnableAltLedread-writecurrentBoot flag for enableing Alternate LED
1.3.6.1.4.1.2272.1.100.5.1.24Columnrc2kBootConfigPrimaryBackupConfigSourceread-writecurrentprimary backup config source (save config)
1.3.6.1.4.1.2272.1.100.5.1.25Columnrc2kBootConfigSecondaryBackupConfigSourceread-writecurrentsecondary backup config source (save config)
1.3.6.1.4.1.2272.1.100.5.1.26Columnrc2kBootConfigTertiaryBackupConfigSourceread-writecurrenttertiary backup config source (save config)
1.3.6.1.4.1.2272.1.100.5.1.27Columnrc2kBootConfigEnable8616ReAutonegread-writecurrentEnable re-autoneg for 8616SX Cards (Intel GMAC fix)
1.3.6.1.4.1.2272.1.100.5.1.28Columnrc2kBootConfigMezzImageSourceread-writecurrentMezz image source
1.3.6.1.4.1.2272.1.100.5.1.29Columnrc2kBootConfigEnableMezzread-writecurrentEnable/disable Mezz Flag
1.3.6.1.4.1.2272.1.100.5.1.30Columnrc2kBootConfigPrimaryLicenseSourceread-writecurrentPrimary choice for the license source
1.3.6.1.4.1.2272.1.100.5.1.31Columnrc2kBootConfigSecondaryLicenseSourceread-writecurrentSecondary choice for the license source
1.3.6.1.4.1.2272.1.100.5.1.32Columnrc2kBootConfigTertiaryLicenseSourceread-writecurrentTertiary choice for the license source
1.3.6.1.4.1.2272.1.100.5.1.33Columnrc2kBootConfigUnknownDstMacDiscardread-writeobsoleteEnable/disable to discard the unknown destination mac address. A device reboot is required for the change to take effect.
1.3.6.1.4.1.2272.1.100.5.1.34Columnrc2kBootConfigUnknownDstMacDiscardOperStatusread-onlyobsoleteIndicates the device operational status of unknown destination mac discard.
1.3.6.1.4.1.2272.1.100.5.1.35Columnrc2kBootConfigEnableAutoAssignIpread-writecurrentEnable/disable auto-assign-ip feature
1.3.6.1.4.1.2272.1.100.5.1.36Columnrc2kBootConfigUpgradeBootImageSourceread-writecurrentUpgrade boot image source
1.3.6.1.4.1.2272.1.100.5.1.37Columnrc2kBootConfigUpgradeRuntimeImageSourceread-writecurrentUpgrade runtime image source
1.3.6.1.4.1.2272.1.100.5.1.38Columnrc2kBootConfigUpgradeMezzImageSourceread-writecurrentUpgrade mezz image source
1.3.6.1.4.1.2272.1.100.5.1.39Columnrc2kBootConfigUpgradeConfigSourceread-writecurrentUpgrade config source
1.3.6.1.4.1.2272.1.100.5.1.40Columnrc2kBootConfigUpgradeRModImageSourceread-writecurrentupgrade RMod image source
1.3.6.1.4.1.2272.1.100.5.1.41Columnrc2kBootConfigUpgradeRCModImageSourceread-writecurrentupgrade RCMod image source
1.3.6.1.4.1.2272.1.100.5.1.42Columnrc2kBootConfigUpgradeESMImageSourceread-writecurrentupgrade ESM image source
1.3.6.1.4.1.2272.1.100.5.1.43Columnrc2kBootConfigFallBackBootImageSourceread-writecurrentupgrade fall-back boot monitor source
1.3.6.1.4.1.2272.1.100.5.1.44Columnrc2kBootConfigEnableCfPcCompatread-writecurrentEnable/disable CF PC compatibility
1.3.6.1.4.1.2272.1.100.5.1.45Columnrc2kBootConfigLinecardCompatibilityModeread-writecurrentThis indicates the compatibility mode of the IO cards on the Chassis. In gen1 mode, both the generation 1 cards and generation 2 (ROF) cards will be supported …
1.3.6.1.4.1.2272.1.100.5.1.46Columnrc2kBootConfigEnableSpbmConfigModeread-writecurrentEnables spbm-config-mode boot flag. When this flag is true, SPBM configurations are allowed and PIM configurations are disabled and not allowed. When this flag…
1.3.6.1.4.1.2272.1.100.5.1.47Columnrc2kBootConfigEnableIpv6Moderead-writecurrentEnable/disable Ipv6-Mode Flag.This flag is used only for VSP8200 and VSP4k because of the limitation in Trident2 where Ipv6 route with prefix-length >64 cannot…
1.3.6.1.4.1.2272.1.100.5.1.48Columnrc2kBootConfigEnableEnhancedsecureModeread-writecurrentEnable/disable Federal Mode Flag
1.3.6.1.4.1.2272.1.100.5.1.49Columnrc2kBootConfigEnableUrpfModeread-writecurrentFrom VOSS5.x onwards, unicast reverse path forwarding will be supported on small system platforms only if this flag is enabled.
1.3.6.1.4.1.2272.1.100.5.1.50Columnrc2kBootConfigEnableFlowControlModeread-writecurrentEnable/disable Flow Control Mode Flag.
1.3.6.1.4.1.2272.1.100.5.1.51Columnrc2kBootConfigAdvancedFeatureBwReservationread-writecurrentAllow to enable the port forwarding bandwidth working as loopback ports to support advanced feature mode, or disable the reservation for full port mode. Enable…
1.3.6.1.4.1.2272.1.100.5.1.52Columnrc2kBootConfigEnableVxlanGwFullInterworkingModeread-writecurrentEnables vxlan gateway full interworking mode.
1.3.6.1.4.1.2272.1.100.5.1.53Columnrc2kBootConfigNniMstpread-writecurrentFlag to decide whether configuration of mstp and other vlans on the NNI is allowed. Default is not allowed.
1.3.6.1.4.1.2272.1.100.5.1.54Columnrc2kBootConfigEnableDvrLeafModeread-writecurrentDVR can be configured as controller or leaf. IP related configuration and show commands are not allowed on leaf. dvr-leaf-mode flag has to be enabled first bef…
1.3.6.1.4.1.2272.1.100.5.1.55Columnrc2kBootConfigEnablevrfScalingread-writecurrentFlag to Enable or Disable vrf scaling.
1.3.6.1.4.1.2272.1.100.5.1.56Columnrc2kBootConfigLinerateDirectedBroadcastread-writecurrentFlag to Enable or Disable Linerate Directed Broadcast. With this flag set, IP directed broadcast will operate at linerate. Without this flag, all IP directed b…
1.3.6.1.4.1.2272.1.100.5.1.57Columnrc2kBootConfigVcModeread-writecurrentFlag to Enable or Disable Virtual Chassis mode.
1.3.6.1.4.1.2272.1.100.5.1.58Columnrc2kBootConfigEnableIpv6EgressFilterModeread-writecurrentFlag to enable or disable the IPV6 egress filter
1.3.6.1.4.1.2272.1.100.5.1.59Columnrc2kBootConfigEnableSyslogRfc5424Formatread-writecurrentFlag to enable or disable the syslog output format. Enable will align syslog format with RFC 5424.
1.3.6.1.4.1.2272.1.100.5.1.60Columnrc2kBootConfigEnableFactoryDefaultsModeread-writecurrentSet Factory default boot wiht option. This object is used to deprecate and obsolete the rc2kBootConfigEnableFactoryDefaults disable(1): System boot up with no …
1.3.6.1.4.1.2272.1.100.5.1.61Columnrc2kBootConfigInsightPortConnectTyperead-writecurrentThis object indicates the desired insight port connect type of the system. The valid values are: vtd(1) ovs-sriov(2) Note that changing the insight port connec…
1.3.6.1.4.1.2272.1.100.6Tablerc2kCardTablenot-accessiblecurrent2k Card table
1.3.6.1.4.1.2272.1.100.6.1Rowrc2kCardEntrynot-accessiblecurrentEntry containing information of 2k Card
1.3.6.1.4.1.2272.1.100.6.1.1Columnrc2kCardIndexread-onlycurrentslot number.
1.3.6.1.4.1.2272.1.100.6.1.2Columnrc2kCardFrontTyperead-onlycurrentUsed to indicate card types in the Accelar 8000 product families. For Accelar 8000 devices, all cards use an encoded value according to the following rule: Exa…
1.3.6.1.4.1.2272.1.100.6.1.3Columnrc2kCardFrontDescriptionread-onlycurrentdescription
1.3.6.1.4.1.2272.1.100.6.1.4Columnrc2kCardFrontAdminStatusread-writecurrentUsed to indicate the administrative status of this card
1.3.6.1.4.1.2272.1.100.6.1.5Columnrc2kCardFrontOperStatusread-onlycurrentUsed to indicate the operational status of this card.
1.3.6.1.4.1.2272.1.100.6.1.6Columnrc2kCardFrontSerialNumread-onlycurrentserial number of card
1.3.6.1.4.1.2272.1.100.6.1.7Columnrc2kCardFrontHwVersionread-onlycurrenthardware version
1.3.6.1.4.1.2272.1.100.6.1.8Columnrc2kCardFrontPartNumberread-onlycurrentpart number
1.3.6.1.4.1.2272.1.100.6.1.9Columnrc2kCardFrontDateCoderead-onlycurrentdate code
1.3.6.1.4.1.2272.1.100.6.1.10Columnrc2kCardFrontDeviationsread-onlycurrentdeviations
1.3.6.1.4.1.2272.1.100.6.1.11Columnrc2kCardFrontMacAddrread-onlyobsoletebase mac address
1.3.6.1.4.1.2272.1.100.6.1.12Columnrc2kCardBackTyperead-onlycurrentRefer to rc2kCardFrontType for the encoding scheme
1.3.6.1.4.1.2272.1.100.6.1.13Columnrc2kCardBackDescriptionread-onlycurrentdescription
1.3.6.1.4.1.2272.1.100.6.1.14Columnrc2kCardBackSerialNumread-onlycurrentserial number of card
1.3.6.1.4.1.2272.1.100.6.1.15Columnrc2kCardBackHwVersionread-onlycurrenthardware version
1.3.6.1.4.1.2272.1.100.6.1.16Columnrc2kCardBackPartNumberread-onlycurrentpart number
1.3.6.1.4.1.2272.1.100.6.1.17Columnrc2kCardBackDateCoderead-onlycurrentdate code
1.3.6.1.4.1.2272.1.100.6.1.18Columnrc2kCardBackDeviationsread-onlycurrentdeviations
1.3.6.1.4.1.2272.1.100.6.1.19Columnrc2kCardPCMCIATyperead-onlycurrentUsed to indicate the type of PCMCIA card currently installed in this CPU card, if any. For non-CPU cards, this variable has no meaning and will always be set t…
1.3.6.1.4.1.2272.1.100.6.1.20Columnrc2kCardPCMCIADescrread-onlycurrentPCMCIA descriptor
1.3.6.1.4.1.2272.1.100.6.1.21Columnrc2kCardASICDescrread-onlycurrentASIC descriptor
1.3.6.1.4.1.2272.1.100.6.1.22Columnrc2kCardFrontMasterIOread-onlycurrentUsed to indicate whether an IO card in a 8100 device is operating in the 'master' mode. This variable is not meaningful for non-IO cards and non-8100 devices.
1.3.6.1.4.1.2272.1.100.6.1.23Columnrc2kCardSmltOnSingleCpSupportedread-onlycurrentUsed to indicate whether an IO card is updated to support SMLT on single Cp feature or not.
1.3.6.1.4.1.2272.1.100.6.1.24Columnrc2kCardMezzCardread-onlycurrentUsed to indicate the CPU Mezz card
1.3.6.1.4.1.2272.1.100.6.1.25Columnrc2kCardFrontPoeOperStatusread-onlycurrentUsed to indicate the operational status of this card.
1.3.6.1.4.1.2272.1.100.6.1.26Columnrc2kCardMezzSerialNumread-onlycurrentUsed to get the serial number of the mezz
1.3.6.1.4.1.2272.1.100.6.1.27Columnrc2kCardMezzHwVersionread-onlycurrentUsed to get the HW version of the mezz. The value of HW Version corresponds to the value of part number.
1.3.6.1.4.1.2272.1.100.6.1.28Columnrc2kCardMezzPartNumread-onlycurrentUsed to get the part number of the mezz. The value of part number corresponds to the value of HW Version.
1.3.6.1.4.1.2272.1.100.6.1.29Columnrc2kCardSlotPriorityread-writecurrentUsed to indicate the priority of the slot for power management.It will take effect only after reboot.
1.3.6.1.4.1.2272.1.100.6.1.30Columnrc2kCardSlotOriginalPriorityread-onlycurrentPriority of the slot for power management which the swtich has currently booted with. It will remain the same until the next reboot.
1.3.6.1.4.1.2272.1.100.6.1.31Columnrc2kCardModeread-writecurrentUsed to indicate the single port or dual port is using
1.3.6.1.4.1.2272.1.100.6.1.32Columnrc2kCardSlotPowerread-writecurrentAdministrately turn on or off power on this slot. it only applicable on Standby CP & IO and SF Card
1.3.6.1.4.1.2272.1.100.6.1.33Columnrc2kCardModuleSerialNumread-onlycurrentModule serial number. It is only applicable to the RS module. And it is not applicable to old version of the R module and CP
1.3.6.1.4.1.2272.1.100.6.1.34Columnrc2kCardModulePartNumberread-onlycurrentModule part number. It is only applicable to the RS module. And it is not applicable to old version of the R module and CP
1.3.6.1.4.1.2272.1.100.6.1.35Columnrc2kCardModuleAssemblyDateread-onlycurrentModule assemly date. It is only applicable to the RS module. And it is not applicable to old version of the R module and CP
1.3.6.1.4.1.2272.1.100.7Noderc2kCopyFile
1.3.6.1.4.1.2272.1.100.7.1Scalarrc2kCopyFileSourceread-writecurrentsource file
1.3.6.1.4.1.2272.1.100.7.2Scalarrc2kCopyFileDestinationread-writecurrentdest file
1.3.6.1.4.1.2272.1.100.7.3Scalarrc2kCopyFileActionread-writecurrentstart or cancell
1.3.6.1.4.1.2272.1.100.7.4Scalarrc2kCopyFileResultread-onlycurrentresult
1.3.6.1.4.1.2272.1.100.8Noderc2kQos
1.3.6.1.4.1.2272.1.100.9Noderc2kAtm
1.3.6.1.4.1.2272.1.100.10Tablerc2kMdaCardTablenot-accessiblecurrentMda card table
1.3.6.1.4.1.2272.1.100.10.1Rowrc2kMdaCardEntrynot-accessiblecurrentEntry containing infomation of Mda card
1.3.6.1.4.1.2272.1.100.10.1.1Columnrc2kMdaCardSlotNumread-onlycurrentSlot number
1.3.6.1.4.1.2272.1.100.10.1.2Columnrc2kMdaCardMdaNumread-onlycurrentMDA number within slot. MDAs are numbered from left to right.
1.3.6.1.4.1.2272.1.100.10.1.3Columnrc2kMdaCardTyperead-onlycurrentRefer to rc2kCardFrontType for the encoding scheme
1.3.6.1.4.1.2272.1.100.10.1.4Columnrc2kMdaCardDescriptionread-onlycurrentdescription of mda card
1.3.6.1.4.1.2272.1.100.10.1.5Columnrc2kMdaCardAdminStatusread-writecurrentadministration status of mda card
1.3.6.1.4.1.2272.1.100.10.1.6Columnrc2kMdaCardOperStatusread-onlycurrentoperation status of mda card.
1.3.6.1.4.1.2272.1.100.10.1.7Columnrc2kMdaCardSerialNumread-onlycurrentserial number of mad card
1.3.6.1.4.1.2272.1.100.10.1.8Columnrc2kMdaCardHwVersionread-onlycurrenthardware version of mda card
1.3.6.1.4.1.2272.1.100.10.1.9Columnrc2kMdaCardPartNumberread-onlycurrentpart number of mda card
1.3.6.1.4.1.2272.1.100.10.1.10Columnrc2kMdaCardDateCoderead-onlycurrentdate code of mda card
1.3.6.1.4.1.2272.1.100.10.1.11Columnrc2kMdaCardDeviationsread-onlycurrenthardware deviation infomation of mda card
1.3.6.1.4.1.2272.1.100.10.1.12Columnrc2kMdaCardMacAddrread-onlycurrentbase mac address of mda card
1.3.6.1.4.1.2272.1.100.10.1.13Columnrc2kMdaCardNumPortsread-onlycurrentnumber of ports on mda card
1.3.6.1.4.1.2272.1.100.10.1.14Columnrc2kMdaCardFirstIfIndexread-onlycurrentfirst ifindex number on mda card
1.3.6.1.4.1.2272.1.100.10.1.15Columnrc2kMdaCardLastIfIndexread-onlycurrentlast ifindex number on mda card
1.3.6.1.4.1.2272.1.100.11Tablerc2kCpuEthernetPortRouteTablenot-accessiblecurrent2k CPU Ethernet Port Route table
1.3.6.1.4.1.2272.1.100.11.1Rowrc2kCpuEthernetPortRouteEntrynot-accessiblecurrentEntry containing infomation of 2k CPU Ethernet Port
1.3.6.1.4.1.2272.1.100.11.1.1Columnrc2kCpuEthernetPortRouteNetworkread-writecurrentUsed to configure the network that can be used to remotely manage this device.
1.3.6.1.4.1.2272.1.100.11.1.2Columnrc2kCpuEthernetPortRouteGatewayread-writecurrentUsed to configure the the IP address of the gateway that should be used to forward IP traffic.
1.3.6.1.4.1.2272.1.100.11.1.3Columnrc2kCpuEthernetPortRouteRowStatusread-writecurrentrow status
1.3.6.1.4.1.2272.1.100.12Noderc2kCPUTypeGeneralGroup
1.3.6.1.4.1.2272.1.100.12.1Scalarrc2kCPUTypePrimaryread-onlycurrentThis enum type will distinguish one CPU type from the other.
1.3.6.1.4.1.2272.1.100.12.2Scalarrc2kCPUTypeSecondaryread-onlycurrentThis type will distinguish one Secondary CPU type from the other.
1.3.6.1.4.1.2272.1.100.12.3Scalarrc2kCPUTypePrimaryMemoryread-onlycurrentThis gives the memory size of the Primary CPU type.
1.3.6.1.4.1.2272.1.100.12.4Scalarrc2kCPUTypeSecondaryMemoryread-onlycurrentThis gives the memory size of the Secondary CPU type.
1.3.6.1.4.1.2272.1.100.13Tablerc2kCpuEthernetPortIpv6RouteTablenot-accessiblecurrent2k CPU Ethernet Port Route table for Ipv6
1.3.6.1.4.1.2272.1.100.13.1Rowrc2kCpuEthernetPortIpv6RouteEntrynot-accessiblecurrentEntry containing information of 2k CPU Ethernet Port Ipv6
1.3.6.1.4.1.2272.1.100.13.1.1Columnrc2kCpuEthernetPortIpv6RouteNetworknot-accessiblecurrentUsed to configure the ipv6 network that can be used to remotely manage this device.
1.3.6.1.4.1.2272.1.100.13.1.2Columnrc2kCpuEthernetPortIpv6RoutePrefixLengthnot-accessiblecurrentThe length of the prefix (in bits).
1.3.6.1.4.1.2272.1.100.13.1.3Columnrc2kCpuEthernetPortIpv6RouteGatewaynot-accessiblecurrentUsed to configure the the IPv6 address of the gateway that should be used to forward IPv6 traffic.
1.3.6.1.4.1.2272.1.100.13.1.4Columnrc2kCpuEthernetPortIpv6RouteRowStatusread-createcurrentrow status
1.3.6.1.4.1.2272.1.100.14Tablerc2kCardModTablenot-accessiblecurrentRTM info table
1.3.6.1.4.1.2272.1.100.14.1Rowrc2kCardModEntrynot-accessiblecurrentEntry containing RTM information
1.3.6.1.4.1.2272.1.100.14.1.1Columnrc2kCardModIndexnot-accessiblecurrentslot number.
1.3.6.1.4.1.2272.1.100.14.1.2Columnrc2kCardModPresentread-onlycurrentIndicates if the RTM in this slot is present
1.3.6.1.4.1.2272.1.100.14.1.3Columnrc2kCardModTyperead-onlycurrentRTM type
1.3.6.1.4.1.2272.1.100.14.1.4Columnrc2kCardModDescriptionread-onlycurrentRTM description
1.3.6.1.4.1.2272.1.100.14.1.5Columnrc2kCardModSerialNumread-onlycurrentRTM serial number
1.3.6.1.4.1.2272.1.100.14.1.6Columnrc2kCardModHwVersionread-onlycurrentRTM hardware version
1.3.6.1.4.1.2272.1.100.14.1.7Columnrc2kCardModPartNumberread-onlycurrentRTM part number
1.3.6.1.4.1.2272.1.100.14.1.8Columnrc2kCardModDateCoderead-onlycurrentRTM date code
1.3.6.1.4.1.2272.1.100.14.1.9Columnrc2kCardModDeviationsread-onlycurrentRTM deviations
1.3.6.1.4.1.2272.1.100.14.1.10Columnrc2kCardModCpldIdread-onlycurrentRTM CPLD ID value
1.3.6.1.4.1.2272.1.100.14.1.11Columnrc2kCardModCpldRevread-onlycurrentRTM CPLD revision value
1.3.6.1.4.1.2272.1.100.15Tablerc2kCardPerfTablenot-accessiblecurrentThis table represents the Card/Slot level DRAM size, DRAM Used, DRAM Free and CPU Utilization for the R Module and RC Module cards
1.3.6.1.4.1.2272.1.100.15.1Rowrc2kCardPerfEntrynot-accessiblecurrentEntry containing information of Card performance
1.3.6.1.4.1.2272.1.100.15.1.1Columnrc2kCardPerfIdnot-accessiblecurrentThis represents the slot number. This is only for line cards, slot 5 and 6 should not be used.
1.3.6.1.4.1.2272.1.100.15.1.2Columnrc2kCardPerfDramSizeread-onlycurrentThis represents DRAM Size in Mega bytes
1.3.6.1.4.1.2272.1.100.15.1.3Columnrc2kCardPerfDramUsedread-onlycurrentThis represents the amount of DRAM used in kilo bytes
1.3.6.1.4.1.2272.1.100.15.1.4Columnrc2kCardPerfDramFreeread-onlycurrentThis represents the amount of DRAM Free in kilo bytes
1.3.6.1.4.1.2272.1.100.15.1.5Columnrc2kCardPerfCPUUtilizationread-onlycurrentThis represents the percentage of CPU utilization
1.3.6.1.4.1.2272.1.100.16Tablerc2kSysAggrRateLimiterStatsTablenot-accessiblecurrentThis table represents the Card/Slot level Aggregate rate limiter stats for power ranger cards.
1.3.6.1.4.1.2272.1.100.16.1Rowrc2kSysAggrRateLimiterStatsEntrynot-accessiblecurrentCard/Slot level Aggregate rate limiter stats for power ranger cards indexed by slot number
1.3.6.1.4.1.2272.1.100.16.1.1Columnrc2kSysAggrRateLimiterStatsIdnot-accessiblecurrentThis represents the slot number. This is only for line cards, slot 5 and 6 should not be used.
1.3.6.1.4.1.2272.1.100.16.1.2Columnrc2kSysAggrRateLimiterIngGreenLane0read-onlycurrentNumber of packets passed or marked green by the Ingress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.3Columnrc2kSysAggrRateLimiterIngRedLane0read-onlycurrentNumber of packets dropped or marked red by the Ingress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.4Columnrc2kSysAggrRateLimiterEgrGreenLane0read-onlycurrentNumber of packets passed or marked green by the Egress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.5Columnrc2kSysAggrRateLimiterEgrRedLane0read-onlycurrentNumber of packets dropped or marked red by the Egress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.6Columnrc2kSysAggrRateLimiterIngGreenLane1read-onlycurrentNumber of packets passed or marked green by the Ingress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.7Columnrc2kSysAggrRateLimiterIngRedLane1read-onlycurrentNumber of packets dropped or marked red by the Ingress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.8Columnrc2kSysAggrRateLimiterEgrGreenLane1read-onlycurrentNumber of packets passed or marked green by the Egress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.9Columnrc2kSysAggrRateLimiterEgrRedLane1read-onlycurrentNumber of packets dropped or marked red by the Egress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.10Columnrc2kSysAggrRateLimiterIngGreenLane2read-onlycurrentNumber of packets passed or marked green by the Ingress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.11Columnrc2kSysAggrRateLimiterIngRedLane2read-onlycurrentNumber of packets dropped or marked red by the Ingress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.12Columnrc2kSysAggrRateLimiterEgrGreenLane2read-onlycurrentNumber of packets passed or marked green by the Egress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.13Columnrc2kSysAggrRateLimiterEgrRedLane2read-onlycurrentNumber of packets dropped or marked red by the Egress Aggregate rate limiter
1.3.6.1.4.1.2272.1.100.16.1.14Columnrc2kSysAggrRateLimiterStatsClearread-writecurrentClear the Aggregate Rate limiter Stats
1.3.6.1.4.1.2272.1.100.17Tablerc2kPowerConsumptionInfoTablenot-accessiblecurrentPower consumption info table for all slots
1.3.6.1.4.1.2272.1.100.17.1Rowrc2kPowerConsumptionInfoEntrynot-accessiblecurrentEntry containing power consumption information of the slot
1.3.6.1.4.1.2272.1.100.17.1.1Columnrc2kPowerConsumptionInfoIndexnot-accessiblecurrentSlot number.
1.3.6.1.4.1.2272.1.100.17.1.2Columnrc2kPowerConsumptionInfoPowerStatusread-onlycurrentPower operation status of this slot
1.3.6.1.4.1.2272.1.100.17.1.3Columnrc2kPowerConsumptionInfoBasePowerread-onlycurrentThe base power required for this slot
1.3.6.1.4.1.2272.1.100.17.1.4Columnrc2kPowerConsumptionInfoConsumedPowerread-onlycurrentThe actual consumed power of this slot. Value will be set zero when Power status is 'off' rc2kPowerConsumptionInfoPowerStatus
1.3.6.1.4.1.2272.1.100.17.1.5Columnrc2kPowerConsumptionInfoPowerPriorityread-onlycurrentUsed to indicate the priority of the slot for power management
1.3.6.1.4.1.2272.1.100.17.1.6Columnrc2kPowerConsumptionInfoSlotDescriptionread-onlycurrentUser to indicate the slot type information. Such as, 'Slot1'..'Slot12', 'SF1'..'SF4'..etc
1.3.6.1.4.1.2272.1.100.17.1.7Columnrc2kPowerConsumptionInfoCardDescriptionread-onlycurrentHardware description of this card
1.3.6.1.4.1.2272.1.100.18Tablerc2kTemperatureTablenot-accessiblecurrentTable for retrieving the temperatures of each card (CP, IO, SF) on the chassis
1.3.6.1.4.1.2272.1.100.18.1Rowrc2kTemperatureEntrynot-accessiblecurrentContains information regarding the temperature of each slot (CP, IO and SF) on the chassis.
1.3.6.1.4.1.2272.1.100.18.1.1Columnrc2kTemperatureSlotIndexnot-accessiblecurrentSlot number of either a CP (1,2) or IO (3-12) or SF (21-26).
1.3.6.1.4.1.2272.1.100.18.1.2Columnrc2kTemperatureSlotDescriptionread-onlycurrentUsed to indicate the slot type information. Such as, 'Slot1'..'Slot12', 'SF1'..'SF4'..etc.
1.3.6.1.4.1.2272.1.100.18.1.3Columnrc2kTemperatureZone1Temperatureread-onlycurrentZone 1 temperature measured in celsius degree
1.3.6.1.4.1.2272.1.100.18.1.4Columnrc2kTemperatureZone2Temperatureread-onlycurrentZone 2 temperature measured in celsius degree. A value of 0 for this mib object indicates that Zone 2 is not available on this slot.
1.3.6.1.4.1.2272.1.100.18.1.5Columnrc2kTemperatureZone3Temperatureread-onlycurrentZone 3 temperature measured in celsius degree. A value of 0 for this mib object indicates that Zone 3 is not available on this slot.
1.3.6.1.4.1.2272.1.100.18.1.6Columnrc2kTemperatureZone4Temperatureread-onlycurrentZone 4 temperature measured in celsius degree
1.3.6.1.4.1.2272.1.100.18.1.7Columnrc2kTemperatureZone5Temperatureread-onlycurrentZone 5 temperature measured in celsius degree. A value of 0 for this mib object indicates that Zone 5 is not available on this slot.
1.3.6.1.4.1.2272.1.100.18.1.8Columnrc2kTemperatureHighTemperatureread-onlycurrentHighest temperature measured in celsius degree
1.3.6.1.4.1.2272.1.100.18.1.9Columnrc2kTemperatureLowTemperatureread-onlycurrentLowest temperature measured in celsius degree
1.3.6.1.4.1.2272.1.100.18.1.10Columnrc2kTemperatureAlarmThresholdread-onlycurrentWhen the card temperature crosses this threshold, an alarm will be set.
1.3.6.1.4.1.2272.1.100.18.1.11Columnrc2kTemperatureShutdownThresholdread-onlycurrentWhen the card temperature crosses this threshold, the card will be shutdown.
1.3.6.1.4.1.2272.1.100.19Tablerc2kUsbTablenot-accessiblecurrentTable for retrieving the data for the USBs inserted on the chassis
1.3.6.1.4.1.2272.1.100.19.1Rowrc2kUsbEntrynot-accessiblecurrentContains information regarding the data for USBs inserted on the chassis
1.3.6.1.4.1.2272.1.100.19.1.1Columnrc2kUsbSlotIndexnot-accessiblecurrentSlot number of CP in which USB is inserted.
1.3.6.1.4.1.2272.1.100.19.1.2Columnrc2kUsbSlotDescriptionread-onlycurrentUsed to indicate the slot type information. Such as, 'Slot1'..'Slot2.
1.3.6.1.4.1.2272.1.100.19.1.3Columnrc2kUsbVendorIdread-onlycurrentIndicates the Vendor Id for the inserted USB. Value is assigned by USB-IF.
1.3.6.1.4.1.2272.1.100.19.1.4Columnrc2kUsbManufacturerread-onlycurrentIndicates the Manufacturer for the inserted USB.
1.3.6.1.4.1.2272.1.100.19.1.5Columnrc2kUsbProductIdread-onlycurrentIndicates the Product Id for the inserted USB. Value is assigned by manufacturer.
1.3.6.1.4.1.2272.1.100.19.1.6Columnrc2kUsbProductNameread-onlycurrentIndicates the Product Name for the inserted USB.
1.3.6.1.4.1.2272.1.100.19.1.7Columnrc2kUsbSerialNumberread-onlycurrentIndicates the Serial Number for the inserted USB.
1.3.6.1.4.1.2272.1.100.19.1.8Columnrc2kUsbRevisionread-onlycurrentIndicates the release number for the inserted USB.
1.3.6.1.4.1.2272.1.100.19.1.9Columnrc2kUsbMaxCurrentread-onlycurrentReturns the Max Power as defined by specification for the inserted USB. The units are milliamps.
1.3.6.1.4.1.2272.1.100.20Tablerc2kCardAsicInfoTablenot-accessiblecurrentA table that contains asic information that is specific to a forwarding slice on a second generation IO module.
1.3.6.1.4.1.2272.1.100.20.1Rowrc2kCardAsicInfoEntrynot-accessiblecurrentSecond Generation Card attributes
1.3.6.1.4.1.2272.1.100.20.1.1Columnrc2kCardAsicInfoIndexnot-accessiblecurrentA unique value for each module within the chassis. This value is determined by the chassis slot number where the module is inserted. Valid entries are 3 to the…
1.3.6.1.4.1.2272.1.100.20.1.2Columnrc2kCardAsicInfoForwardingSlicenot-accessiblecurrentA unique value for each forwarding slice on the card.
1.3.6.1.4.1.2272.1.100.20.1.3Columnrc2kCardAsicInfoQEread-onlycurrentQE version for the forwarding slice on IO card
1.3.6.1.4.1.2272.1.100.20.1.4Columnrc2kCardAsicInfoZagrosFpgaread-onlycurrentZagros FPGA for the forwarding slice on IO card
1.3.6.1.4.1.2272.1.100.20.1.5Columnrc2kCardAsicInfoRspread-onlycurrentRSP for the forwarding slice on IO card
1.3.6.1.4.1.2272.1.100.20.1.6Columnrc2kCardAsicInfoPhyRevread-onlycurrentPHY revision for the forwarding slice on IO card
1.3.6.1.4.1.2272.1.100.21Tablerc2kIoCardTemperatureTablenot-accessiblecurrentTable for retrieving the temperatures of the sensors located on the FPGA's and FA's on the generation 2 IO cards.
1.3.6.1.4.1.2272.1.100.21.1Rowrc2kIoCardTemperatureEntrynot-accessiblecurrentContains information regarding the temperatures of FPGA's and FA's on the generation 2 IO cards.
1.3.6.1.4.1.2272.1.100.21.1.1Columnrc2kIoCardTemperatureSlotIndexnot-accessiblecurrentSlot number of the IO card
1.3.6.1.4.1.2272.1.100.21.1.2Columnrc2kIoCardTemperatureFPGASensor1Temperatureread-onlycurrentTemperature of the FPGA Sensor 1, located on the Zagros on the first slice, measured in celsius degrees. A value of 0 for this mib object indicates that this s…
1.3.6.1.4.1.2272.1.100.21.1.3Columnrc2kIoCardTemperatureFPGASensor2Temperatureread-onlycurrentTemperature of the FPGA Sensor 2, located on the Zagros on the first slice, measured in celsius degrees. A value of 0 for this mib object indicates that this s…
1.3.6.1.4.1.2272.1.100.21.1.4Columnrc2kIoCardTemperatureFPGASensor3Temperatureread-onlycurrentTemperature of the FPGA Sensor 3, located on the RSP on the first slice, measured in celsius degrees. A value of 0 for this mib object indicates that this sens…
1.3.6.1.4.1.2272.1.100.21.1.5Columnrc2kIoCardTemperatureFPGASensor4Temperatureread-onlycurrentTemperature of the FPGA Sensor 4, located on the Zagros on the second slice, measured in celsius degrees. A value of 0 for this mib object indicates that this …
1.3.6.1.4.1.2272.1.100.21.1.6Columnrc2kIoCardTemperatureFPGASensor5Temperatureread-onlycurrentTemperature of the FPGA Sensor 5, located on the Zagros on the second slice, measured in celsius degrees. A value of 0 for this mib object indicates that this …
1.3.6.1.4.1.2272.1.100.21.1.7Columnrc2kIoCardTemperatureFPGASensor6Temperatureread-onlycurrentTemperature of the FPGA Sensor 6, located on the RSP on the second slice, measured in celsius degrees. A value of 0 for this mib object indicates that this sen…
1.3.6.1.4.1.2272.1.100.21.1.8Columnrc2kIoCardTemperatureFPGASensor7Temperatureread-onlycurrentTemperature of the FPGA Sensor 7, located on the Zagros on the third slice, measured in celsius degrees. A value of 0 for this mib object indicates that this s…
1.3.6.1.4.1.2272.1.100.21.1.9Columnrc2kIoCardTemperatureFPGASensor8Temperatureread-onlycurrentTemperature of the FPGA Sensor 8, located on the Zagros on the third slice, measured in celsius degrees. A value of 0 for this mib object indicates that this s…
1.3.6.1.4.1.2272.1.100.21.1.10Columnrc2kIoCardTemperatureFPGASensor9Temperatureread-onlycurrentTemperature of the FPGA Sensor 9, located on the RSP on the third slice, measured in celsius degrees. A value of 0 for this mib object indicates that this sens…
1.3.6.1.4.1.2272.1.100.21.1.11Columnrc2kIoCardTemperatureFPGAZoneHighTemperatureread-onlycurrentHighest temperature of all the FPGA sensors located on this IO card, measured in celsius degrees.
1.3.6.1.4.1.2272.1.100.21.1.12Columnrc2kIoCardTemperatureFPGAZoneLowTemperatureread-onlycurrentLowest temperature of all the FPGA sensors located on this IO card, measured in celsius degrees.
1.3.6.1.4.1.2272.1.100.21.1.13Columnrc2kIoCardTemperatureFPGAZoneAlarmThresholdread-onlycurrentWhen the FPGA temperature crosses this threshold on this IO card, an alarm will be set.
1.3.6.1.4.1.2272.1.100.21.1.14Columnrc2kIoCardTemperatureFPGAZoneShutdownThresholdread-onlycurrentWhen the FPGA temperature crosses this threshold on this IO card, the card will be shutdown.
1.3.6.1.4.1.2272.1.100.21.1.15Columnrc2kIoCardTemperatureFASensor1Temperatureread-onlycurrentTemperature of the FA Sensor 1, located on the first slice, measured in celsius degrees. A value of 0 for this mib object indicates that this sensor is not ava…
1.3.6.1.4.1.2272.1.100.21.1.16Columnrc2kIoCardTemperatureFASensor2Temperatureread-onlycurrentTemperature of the FA Sensor 2, located on the second slice, measured in celsius degrees. A value of 0 for this mib object indicates that this sensor is not av…
1.3.6.1.4.1.2272.1.100.21.1.17Columnrc2kIoCardTemperatureFASensor3Temperatureread-onlycurrentTemperature of the FA Sensor 3, located on the third slice, measured in celsius degrees. A value of 0 for this mib object indicates that this sensor is not ava…
1.3.6.1.4.1.2272.1.100.21.1.18Columnrc2kIoCardTemperatureFAZoneHighTemperatureread-onlycurrentHighest temperature of all the FA sensors located on this IO card, measured in celsius degrees.
1.3.6.1.4.1.2272.1.100.21.1.19Columnrc2kIoCardTemperatureFAZoneLowTemperatureread-onlycurrentLowest temperature of all the FA sensors located on this IO card, measured in celsius degrees.
1.3.6.1.4.1.2272.1.100.21.1.20Columnrc2kIoCardTemperatureFAZoneAlarmThresholdread-onlycurrentWhen the FA temperature crosses this threshold on this IO card, an alarm will be set.
1.3.6.1.4.1.2272.1.100.21.1.21Columnrc2kIoCardTemperatureFAZoneShutdownThresholdread-onlycurrentWhen the FA temperature crosses this threshold on this IO card, the card will be shutdown.
1.3.6.1.4.1.2272.1.100.22Tablerc2kBootConfigHostTablenot-accessiblecurrentTable for the bootconfig host info on the device
1.3.6.1.4.1.2272.1.100.22.1Rowrc2kBootConfigHostEntrynot-accessiblecurrentEntry containing boot config host information.
1.3.6.1.4.1.2272.1.100.22.1.1Columnrc2kBootConfigHostSlotread-onlycurrentslot number, VSP uses 1,2
1.3.6.1.4.1.2272.1.100.22.1.2Columnrc2kBootConfigHostTftpHashread-writecurrentEnables tftp hashing
1.3.6.1.4.1.2272.1.100.22.1.3Columnrc2kBootConfigHostTftpRetransmitread-writecurrentSet tftp retransmit timeout counter
1.3.6.1.4.1.2272.1.100.22.1.4Columnrc2kBootConfigHostTftpTimeoutread-writecurrentSet tftp timeout counter
1.3.6.1.4.1.2272.1.100.22.1.5Columnrc2kBootConfigHostUserread-writecurrentConfigure host user
1.3.6.1.4.1.2272.1.100.22.1.6Columnrc2kBootConfigHostPasswordread-writecurrentConfigure host password