RC-POM-MIB

119 objects
OE MIB for Digital Diagnostic Monitoring of pluggable optical modules
OIDNameAccessStatusDescription
1.3.6.1.4.1.2272.1.71.0IdentityrcPlugOptModTableMibOE MIB for Digital Diagnostic Monitoring of pluggable optical modules
1.3.6.1.4.1.2272.1.71.1TablercPlugOptModTablenot-accessiblecurrentGibc SFF diagnostic info table
1.3.6.1.4.1.2272.1.71.1.1RowrcPlugOptModEntrynot-accessiblecurrentEntry containing info. for a particular port
1.3.6.1.4.1.2272.1.71.1.1.1ColumnrcPlugOptModPortIndexnot-accessiblecurrentAn index value that uniquely identifies a port on a blade or line-card.
1.3.6.1.4.1.2272.1.71.1.1.2ColumnrcPlugOptModDdmStatusMaskread-onlycurrentEach bit other than ddm-ok represents a specific error. Any combination of error bits is allowed.
1.3.6.1.4.1.2272.1.71.1.1.3ColumnrcPlugOptModCalibrationread-onlycurrentThe identifier value indicates type of calibration.
1.3.6.1.4.1.2272.1.71.1.1.4ColumnrcPlugOptModPowerMeasureread-onlycurrentThe identifier value indicates type of external power.
1.3.6.1.4.1.2272.1.71.1.1.5ColumnrcPlugOptModConnectorTyperead-onlycurrentThe connector type is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces. This is an assigned name tha…
1.3.6.1.4.1.2272.1.71.1.1.6ColumnrcPlugOptModVendorNameread-onlycurrentThe vendor name is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces. The vendor name shall be the fu…
1.3.6.1.4.1.2272.1.71.1.1.7ColumnrcPlugOptModVendorPartNumberread-onlycurrentThe vendor part number is a 16 byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces, defining the vendor part numb…
1.3.6.1.4.1.2272.1.71.1.1.8ColumnrcPlugOptModVendorRevNumberread-onlycurrentThe vendor revision number is a 4-byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces, defining the vendor produc…
1.3.6.1.4.1.2272.1.71.1.1.9ColumnrcPlugOptModVendorSNread-onlycurrentThe vendor serial number is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces, defining the vendor se…
1.3.6.1.4.1.2272.1.71.1.1.10ColumnrcPlugOptModVendorDateCoderead-onlycurrentThe date code is an 8-byte field that contains the vendor's date code in ASCII. This field is mandatory and takes the form: YYMMDDLC where YY is the 2 low orde…
1.3.6.1.4.1.2272.1.71.1.1.11ColumnrcPlugOptModPECread-onlycurrentThis is a 16 byte left-justified ASCII field that records the Nortel Product Equipment Code order number for the module. Nortel part numbers are 9 bytes long, …
1.3.6.1.4.1.2272.1.71.1.1.12ColumnrcPlugOptModCLEIread-onlycurrentThis is a 10 byte left-justified ASCII field that records the Nortel supplied Common Language Equipment Identifier code for the device. The CLEI code is a Telc…
1.3.6.1.4.1.2272.1.71.1.1.13ColumnrcPlugOptModSupportsDDMread-onlycurrentThis boolean indicates whether or not the device supports the DDM capability.
1.3.6.1.4.1.2272.1.71.1.1.14ColumnrcPlugOptModAux1Monitoringread-onlycurrentThis value tells what Aux1 is measuring.The values are as follows: 0 Auxiliary monitoring not implemented 1 APD Bias Voltage mV (units of 10 mV) 2 Reserved 3 T…
1.3.6.1.4.1.2272.1.71.1.1.15ColumnrcPlugOptModAux2Monitoringread-onlycurrentThis value tells you what AUX2 is measuring.The values are as follows: 0 Auxiliary monitoring not implemented 1 APD Bias Voltage mV (units of 10 mV) 2 Reserved…
1.3.6.1.4.1.2272.1.71.1.1.16ColumnrcPlugOptModWaveLengthread-onlycurrentNominal transmitter output wavelength at room temperature. It is expressed in nano-meters.
1.3.6.1.4.1.2272.1.71.1.1.17ColumnrcPlugOptModTemperatureread-onlycurrentThis value represents the internally measured module temperature. It is expressed in units of 1/256 of a degree Celsius and can range from -40C to +125C with 0…
1.3.6.1.4.1.2272.1.71.1.1.18ColumnrcPlugOptModTemperatureHighAlarmThresholdread-onlycurrentThis value represents the vendor specified high temperature threshold. If the device temperature exceeds this value, a temperature high is asserted. It is expr…
1.3.6.1.4.1.2272.1.71.1.1.19ColumnrcPlugOptModTemperatureLowAlarmThresholdread-onlycurrentThis value represents the vendor specified low temperature threshold. If the device temperature falls below this value, a temperature low is asserted. It is ex…
1.3.6.1.4.1.2272.1.71.1.1.20ColumnrcPlugOptModTemperatureHighWarningThresholdread-onlycurrentThis value represents the vendor specified high temperature warning threshold. If the device temperature exceeds this value, a temperature high warning is asse…
1.3.6.1.4.1.2272.1.71.1.1.21ColumnrcPlugOptModTemperatureLowWarningThresholdread-onlycurrentThis value represents the vendor specified low temperature warning threshold. If the device temperature falls below this value, a temperature low warning is as…
1.3.6.1.4.1.2272.1.71.1.1.22ColumnrcPlugOptModVoltageread-onlycurrentThis value represents the internally measured supply voltage. It is a positive number expressed in microvolts and can range from 0 to 65535 mV.
1.3.6.1.4.1.2272.1.71.1.1.23ColumnrcPlugOptModVoltageHighAlarmThresholdread-onlycurrentThis value represents the vendor specified high voltage threshold. If the measured voltage exceeds this value, a high voltage is asserted. It is a positive num…
1.3.6.1.4.1.2272.1.71.1.1.24ColumnrcPlugOptModVoltageLowAlarmThresholdread-onlycurrentThis value represents the vendor specified low voltage threshold. If the measured voltage falls below this value, a low voltage is asserted. It is a positive n…
1.3.6.1.4.1.2272.1.71.1.1.25ColumnrcPlugOptModVoltageHighWarningThresholdread-onlycurrentThis value represents the vendor specified high voltage warning threshold. If the measured voltage exceeds this value, a high voltage warning is asserted. It i…
1.3.6.1.4.1.2272.1.71.1.1.26ColumnrcPlugOptModVoltageLowWarningThresholdread-onlycurrentThis value represents the vendor specified low voltage warning threshold. If the measured voltage falls below this value, a low voltage warning is asserted. It…
1.3.6.1.4.1.2272.1.71.1.1.27ColumnrcPlugOptModBiasread-onlycurrentThis value represents the internally measured transmitter laser bias current. It is a positive number expressed in units of 2 microamps and can range from 0 to…
1.3.6.1.4.1.2272.1.71.1.1.28ColumnrcPlugOptModBiasHighAlarmThresholdread-onlycurrentThis value represents the vendor specified high current threshold. If the measured bias current exceeds this value, a high current alarm is asserted. It is a p…
1.3.6.1.4.1.2272.1.71.1.1.29ColumnrcPlugOptModBiasLowAlarmThresholdread-onlycurrentThis value represents the vendor specified low current threshold. If the measured bias current falls below this value, a low current is asserted. It is a posit…
1.3.6.1.4.1.2272.1.71.1.1.30ColumnrcPlugOptModBiasHighWarningThresholdread-onlycurrentThis value represents the vendor specified high current warning threshold. If the measured bias current exceeds this value, a high current warning is asserted.…
1.3.6.1.4.1.2272.1.71.1.1.31ColumnrcPlugOptModBiasLowWarningThresholdread-onlycurrentThis value represents the vendor specified low current warning threshold. If the measured bias current falls below this value, a low current warning is asserte…
1.3.6.1.4.1.2272.1.71.1.1.32ColumnrcPlugOptModTxPowerread-onlycurrentThis value represents the internally measured coupled TX output power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535…
1.3.6.1.4.1.2272.1.71.1.1.33ColumnrcPlugOptModTxPowerHighAlarmThresholdread-onlycurrentThis value represents the vendor specified high transmit power threshold. If the measured transmitter power exceeds this value, a transmitter power high is ass…
1.3.6.1.4.1.2272.1.71.1.1.34ColumnrcPlugOptModTxPowerLowAlarmThresholdread-onlycurrentThis value represents the vendor specified low transmit power threshold. If the measured transmitter power falls below this value, a transmitter power low is a…
1.3.6.1.4.1.2272.1.71.1.1.35ColumnrcPlugOptModTxPowerHighWarningThresholdread-onlycurrentThis value represents the vendor specified high transmit power warning threshold. If the measured transmitter power exceeds this value, a transmitter power hig…
1.3.6.1.4.1.2272.1.71.1.1.36ColumnrcPlugOptModTxPowerLowWarningThresholdread-onlycurrentThis value represents the vendor specified low transmit power warning threshold. If the measured transmitter power falls below this value, a transmitter power …
1.3.6.1.4.1.2272.1.71.1.1.37ColumnrcPlugOptModRxPowerread-onlycurrentThis value represents the internally measured received power. It is a positive number expressed in units of micro watts and can range from 0 to 65.535 mW (-40 …
1.3.6.1.4.1.2272.1.71.1.1.38ColumnrcPlugOptModRxPowerHighAlarmThresholdread-onlycurrentThis value represents the vendor specified high receiver power threshold. If the measured received power exceeds this value, a receiver power high is asserted.…
1.3.6.1.4.1.2272.1.71.1.1.39ColumnrcPlugOptModRxPowerLowAlarmThresholdread-onlycurrentThis value represents the vendor specified low receiver power threshold. If the measured received power falls below this value, a receiver power low is asserte…
1.3.6.1.4.1.2272.1.71.1.1.40ColumnrcPlugOptModRxPowerHighWarningThresholdread-onlycurrentThis value represents the vendor specified high receiver power warning threshold. If the measured received power exceeds this value, a receiver power high warn…
1.3.6.1.4.1.2272.1.71.1.1.41ColumnrcPlugOptModRxPowerLowWarningThresholdread-onlycurrentThis value represents the vendor specified low receiver power warning threshold. If the measured received power falls below this value, a receiver power low wa…
1.3.6.1.4.1.2272.1.71.1.1.42ColumnrcPlugOptModAux1read-onlycurrentThis represents the internally measured A/D value specified.
1.3.6.1.4.1.2272.1.71.1.1.43ColumnrcPlugOptModAux1HighAlarmThresholdread-onlycurrentThis value represents the vendor specified high Aux1 threshold.
1.3.6.1.4.1.2272.1.71.1.1.44ColumnrcPlugOptModAux1LowAlarmThresholdread-onlycurrentThis value represents the vendor specified low Aux1 threshold.
1.3.6.1.4.1.2272.1.71.1.1.45ColumnrcPlugOptModAux1HighWarningThresholdread-onlycurrentThis value represents the vendor specified high Aux1 warning threshold.
1.3.6.1.4.1.2272.1.71.1.1.46ColumnrcPlugOptModAux1LowWarningThresholdread-onlycurrentThis value represents the vendor specified low Aux1 warning threshold.
1.3.6.1.4.1.2272.1.71.1.1.47ColumnrcPlugOptModAux2read-onlycurrentThis represents the internally measured A/D value specified.
1.3.6.1.4.1.2272.1.71.1.1.48ColumnrcPlugOptModAux2HighAlarmThresholdread-onlycurrentThis value represents the vendor specified high Aux1 threshold.
1.3.6.1.4.1.2272.1.71.1.1.49ColumnrcPlugOptModAux2LowAlarmThresholdread-onlycurrentThis value represents the vendor specified low Aux1 threshold.
1.3.6.1.4.1.2272.1.71.1.1.50ColumnrcPlugOptModAux2HighWarningThresholdread-onlycurrentThis value represents the vendor specified high Aux1 warning threshold.
1.3.6.1.4.1.2272.1.71.1.1.51ColumnrcPlugOptModAux2LowWarningThresholdread-onlycurrentThis value represents the vendor specified low Aux1 warning threshold.
1.3.6.1.4.1.2272.1.71.1.1.52ColumnrcPlugOptModTemperatureStatusread-onlycurrentUsed to indicate the current temperature status
1.3.6.1.4.1.2272.1.71.1.1.53ColumnrcPlugOptModVoltageStatusread-onlycurrentUsed to indicate the current voltage status
1.3.6.1.4.1.2272.1.71.1.1.54ColumnrcPlugOptModBiasStatusread-onlycurrentUsed to indicate the current laser bias status
1.3.6.1.4.1.2272.1.71.1.1.55ColumnrcPlugOptModTxPowerStatusread-onlycurrentUsed to indicate the current transmitter power status
1.3.6.1.4.1.2272.1.71.1.1.56ColumnrcPlugOptModRxPowerStatusread-onlycurrentUsed to indicate the current receiver power status
1.3.6.1.4.1.2272.1.71.1.1.57ColumnrcPlugOptModAux1Statusread-onlycurrentUsed to indicate the current Aux1 status
1.3.6.1.4.1.2272.1.71.1.1.58ColumnrcPlugOptModAux2Statusread-onlycurrentUsed to indicate the current Aux2 status
1.3.6.1.4.1.2272.1.71.1.1.59ColumnrcPlugOptModQSFPTx1Biasread-onlycurrentThis value represents the internally measured transmitter laser bias current in channel 1 of QSFP.. It is a positive number expressed in units of 2 microamps a…
1.3.6.1.4.1.2272.1.71.1.1.60ColumnrcPlugOptModQSFPTx2Biasread-onlycurrentThis value represents the internally measured transmitter laser bias current in channel 2 of QSFP.. It is a positive number expressed in units of 2 microamps a…
1.3.6.1.4.1.2272.1.71.1.1.61ColumnrcPlugOptModQSFPTx3Biasread-onlycurrentThis value represents the internally measured transmitter laser bias current in channel 3 of QSFP.. It is a positive number expressed in units of 2 microamps a…
1.3.6.1.4.1.2272.1.71.1.1.62ColumnrcPlugOptModQSFPTx4Biasread-onlycurrentThis value represents the internally measured transmitter laser bias current in channel 4 of QSFP.. It is a positive number expressed in units of 2 microamps a…
1.3.6.1.4.1.2272.1.71.1.1.63ColumnrcPlugOptModQSFPTx1Powerread-onlycurrentThis value represents the internally measured TX output power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range fro…
1.3.6.1.4.1.2272.1.71.1.1.64ColumnrcPlugOptModQSFPTx2Powerread-onlycurrentThis value represents the internally measured TX output power in channel 2 of QSFP. It is a positive number expressed in units of micro watts and can range fro…
1.3.6.1.4.1.2272.1.71.1.1.65ColumnrcPlugOptModQSFPTx3Powerread-onlycurrentThis value represents the internally measured TX output power in channel 3 of QSFP. It is a positive number expressed in units of micro watts and can range fro…
1.3.6.1.4.1.2272.1.71.1.1.66ColumnrcPlugOptModQSFPTx4Powerread-onlycurrentThis value represents the internally measured TX output power in channel 4 of QSFP. It is a positive number expressed in units of micro watts and can range fro…
1.3.6.1.4.1.2272.1.71.1.1.67ColumnrcPlugOptModQSFPRx1Powerread-onlycurrentThis value represents the internally measured received power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range from…
1.3.6.1.4.1.2272.1.71.1.1.68ColumnrcPlugOptModQSFPRx2Powerread-onlycurrentThis value represents the internally measured received power in channel 2 of QSFP. It is a positive number expressed in units of micro watts and can range from…
1.3.6.1.4.1.2272.1.71.1.1.69ColumnrcPlugOptModQSFPRx3Powerread-onlycurrentThis value represents the internally measured received power in channel 3 of QSFP. It is a positive number expressed in units of micro watts and can range from…
1.3.6.1.4.1.2272.1.71.1.1.70ColumnrcPlugOptModQSFPRx4Powerread-onlycurrentThis value represents the internally measured received power in channel 1 of QSFP. It is a positive number expressed in units of micro watts and can range from…
1.3.6.1.4.1.2272.1.71.1.1.71ColumnrcPlugOptModQSFPTx1BiasStatusread-onlycurrentUsed to indicate the current laser bias status in channel 1 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.72ColumnrcPlugOptModQSFPTx2BiasStatusread-onlycurrentUsed to indicate the current laser bias status in channel 2 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.73ColumnrcPlugOptModQSFPTx3BiasStatusread-onlycurrentUsed to indicate the current laser bias status in channel 3 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.74ColumnrcPlugOptModQSFPTx4BiasStatusread-onlycurrentUsed to indicate the current laser bias status in channel 4 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.75ColumnrcPlugOptModQSFPTx1PowerStatusread-onlycurrentUsed to indicate the current transmitter power status in channel 1 of QSFP
1.3.6.1.4.1.2272.1.71.1.1.76ColumnrcPlugOptModQSFPTx2PowerStatusread-onlycurrentUsed to indicate the current transmitter power status in channel 2 of QSFP
1.3.6.1.4.1.2272.1.71.1.1.77ColumnrcPlugOptModQSFPTx3PowerStatusread-onlycurrentUsed to indicate the current transmitter power status in channel 3 of QSFP
1.3.6.1.4.1.2272.1.71.1.1.78ColumnrcPlugOptModQSFPTx4PowerStatusread-onlycurrentUsed to indicate the current transmitter power status in channel 4 of QSFP
1.3.6.1.4.1.2272.1.71.1.1.79ColumnrcPlugOptModQSFPRx1PowerStatusread-onlycurrentUsed to indicate the current receiver power status in channel 1 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.80ColumnrcPlugOptModQSFPRx2PowerStatusread-onlycurrentUsed to indicate the current receiver power status in channel 2 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.81ColumnrcPlugOptModQSFPRx3PowerStatusread-onlycurrentUsed to indicate the current receiver power status in channel 3 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.82ColumnrcPlugOptModQSFPRx4PowerStatusread-onlycurrentUsed to indicate the current receiver power status in channel 4 for QSFP
1.3.6.1.4.1.2272.1.71.1.1.83ColumnrcPlugOptModExtremeSkuread-onlycurrentThis is a 32 bytes field to hold the Extreme SKU number.
1.3.6.1.4.1.2272.1.71.1.1.84ColumnrcPlugOptModPowerOnCounterread-onlycurrentThis value represents the power-on counter. Host increments it by 1 every 48 hours.
1.3.6.1.4.1.2272.1.71.1.1.85ColumnrcPlugOptModTxDdmInitialread-onlycurrentThis value represents the Tx dB from low alarm. Host sets it once only, after the first 48 consecutive hours of operation. Update only if Tx_disable is not act…
1.3.6.1.4.1.2272.1.71.1.1.86ColumnrcPlugOptModTxDdmLastGaspread-onlycurrentThis value represents the last gasp of Tx dB from low alarm. Host updates it every 48 hours. Update only if Tx_disable is not active.
1.3.6.1.4.1.2272.1.71.1.1.87ColumnrcPlugOptModRxDdmInitialread-onlycurrentThis value represents the Rx dB from low alarm. Host sets it after the first 48 consecutive hours of operation since PMD power cycle. Update only if Rx_LOS is …
1.3.6.1.4.1.2272.1.71.1.1.88ColumnrcPlugOptModRxDdmLastGaspread-onlycurrentThis value represents the last gasp of Rx dB from low alarm. Host updates it every 48 hours. Update only if Rx_LOS is not asserted.
1.3.6.1.4.1.2272.1.71.1.1.89ColumnrcPlugOptModQSFPTx1DdmInitialread-onlycurrentThis value represents the Tx dB from low alarm on QSPF channel 1. Host sets it once only, after the first 48 consecutive hours of operation. Update only if Tx_…
1.3.6.1.4.1.2272.1.71.1.1.90ColumnrcPlugOptModQSFPTx1DdmLastGaspread-onlycurrentThis value represents the last gasp of Tx dB from low alarm on QSPF channel 1. Host updates it every 48 hours. Update only if Tx_disable is not active.
1.3.6.1.4.1.2272.1.71.1.1.91ColumnrcPlugOptModQSFPRx1DdmInitialread-onlycurrentThis value represents the Rx dB from low alarm on QSPF channel 1. Host sets it after the first 48 consecutive hours of operation since PMD power cycle. Update …
1.3.6.1.4.1.2272.1.71.1.1.92ColumnrcPlugOptModQSFPRx1DdmLastGaspread-onlycurrentThis value represents the last gasp of Rx dB from low alarm on QSPF channel 1. Host updates it every 48 hours. Update only if Rx_LOS is not asserted.
1.3.6.1.4.1.2272.1.71.1.1.93ColumnrcPlugOptModQSFPTx2DdmInitialread-onlycurrentThis value represents the Tx dB from low alarm on QSPF channel 2. Host sets it once only, after the first 48 consecutive hours of operation. Update only if Tx_…
1.3.6.1.4.1.2272.1.71.1.1.94ColumnrcPlugOptModQSFPTx2DdmLastGaspread-onlycurrentThis value represents the last gasp of Tx dB from low alarm on QSPF channel 2. Host updates it every 48 hours. Update only if Tx_disable is not active.
1.3.6.1.4.1.2272.1.71.1.1.95ColumnrcPlugOptModQSFPRx2DdmInitialread-onlycurrentThis value represents the Rx dB from low alarm on QSPF channel 2. Host sets it after the first 48 consecutive hours of operation since PMD power cycle. Update …
1.3.6.1.4.1.2272.1.71.1.1.96ColumnrcPlugOptModQSFPRx2DdmLastGaspread-onlycurrentThis value represents the last gasp of Rx dB from low alarm on QSPF channel 2. Host updates it every 48 hours. Update only if Rx_LOS is not asserted.
1.3.6.1.4.1.2272.1.71.1.1.97ColumnrcPlugOptModQSFPTx3DdmInitialread-onlycurrentThis value represents the Tx dB from low alarm on QSPF channel 3. Host sets it once only, after the first 48 consecutive hours of operation. Update only if Tx_…
1.3.6.1.4.1.2272.1.71.1.1.98ColumnrcPlugOptModQSFPTx3DdmLastGaspread-onlycurrentThis value represents the last gasp of Tx dB from low alarm on QSPF channel 3. Host updates it every 48 hours. Update only if Tx_disable is not active.
1.3.6.1.4.1.2272.1.71.1.1.99ColumnrcPlugOptModQSFPRx3DdmInitialread-onlycurrentThis value represents the Rx dB from low alarm on QSPF channel 3. Host sets it after the first 48 consecutive hours of operation since PMD power cycle. Update …
1.3.6.1.4.1.2272.1.71.1.1.100ColumnrcPlugOptModQSFPRx3DdmLastGaspread-onlycurrentThis value represents the last gasp of Rx dB from low alarm on QSPF channel 3. Host updates it every 48 hours. Update only if Rx_LOS is not asserted.
1.3.6.1.4.1.2272.1.71.1.1.101ColumnrcPlugOptModQSFPTx4DdmInitialread-onlycurrentThis value represents the Tx dB from low alarm on QSPF channel 4. Host sets it once only, after the first 48 consecutive hours of operation. Update only if Tx_…
1.3.6.1.4.1.2272.1.71.1.1.102ColumnrcPlugOptModQSFPTx4DdmLastGaspread-onlycurrentThis value represents the last gasp of Tx dB from low alarm on QSPF channel 4. Host updates it every 48 hours. Update only if Tx_disable is not active.
1.3.6.1.4.1.2272.1.71.1.1.103ColumnrcPlugOptModQSFPRx4DdmInitialread-onlycurrentThis value represents the Rx dB from low alarm on QSPF channel 4. Host sets it after the first 48 consecutive hours of operation since PMD power cycle. Update …
1.3.6.1.4.1.2272.1.71.1.1.104ColumnrcPlugOptModQSFPRx4DdmLastGaspread-onlycurrentThis value represents the last gasp of Rx dB from low alarm on QSPF channel 4. Host updates it every 48 hours. Update only if Rx_LOS is not asserted.
1.3.6.1.4.1.2272.1.71.1.1.105ColumnrcPlugOptModSupportExtremeExtraFeaturesread-onlycurrentThis boolean indicates whether or not the device supports the Extreme extra features.
1.3.6.1.4.1.2272.1.71.2NodercPlugOptModScalars
1.3.6.1.4.1.2272.1.71.2.1ScalarrcPlugOptModDdmMonitorread-writecurrentEnable/disable the global polling monitor for DDM
1.3.6.1.4.1.2272.1.71.2.2ScalarrcPlugOptModDdmMonitorIntervalread-writecurrentIndicate the interval in which the DDM alert registers is polled
1.3.6.1.4.1.2272.1.71.2.3ScalarrcPlugOptModDdmTrapSendread-writecurrentEnable/disable the global ddm trap send to SNMP manager
1.3.6.1.4.1.2272.1.71.2.4ScalarrcPlugOptModDdmAlarmPortdownread-writecurrentEnable/disable the global portdown option when ddm alarm occurs
1.3.6.1.4.1.2272.1.71.3TablercPlugOptModOperTablenot-accessiblecurrentGibc QSPF table
1.3.6.1.4.1.2272.1.71.3.1RowrcPlugOptModOperEntrynot-accessiblecurrentEntry containing info. for a particular port
1.3.6.1.4.1.2272.1.71.3.1.1ColumnrcPlugOptModOperPortIndexnot-accessiblecurrentAn index value that uniquely identifies a port on a blade or line-card.
1.3.6.1.4.1.2272.1.71.3.1.2ColumnrcPlugOptModOperResetread-writecurrentThis boolean indicates whether or not reset the QSPF on the port.
1.3.6.1.4.1.2272.1.71.4NodercPlugNotificationObjects
1.3.6.1.4.1.2272.1.71.4.1ScalarrcPluggableModuleDescriptionaccessible-for-notifycurrentName or description of the Pluggable module. It is used to by the notification object rcnPlugModInsertedInNotRecommendedPortTrap