MIB Viewer

RFC1382-MIB

170 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMICounter Gauge TimeTicks
RFC1213-MIBDisplayString transmission
RFC1271-MIBEntryStatus
RFC1381-MIBIfIndexType PositiveInteger
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.5Nodex25
1.3.6.1.2.1.10.5.1Tablex25AdmnTablenot-accessiblemandatoryThis table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have correspondi…
1.3.6.1.2.1.10.5.1Nodex25RestartThis trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should s…
1.3.6.1.2.1.10.5.1.1Rowx25AdmnEntrynot-accessiblemandatoryEntries of x25AdmnTable.
1.3.6.1.2.1.10.5.1.1.1Columnx25AdmnIndexread-onlymandatoryThe ifIndex value for the X.25 Interface.
1.3.6.1.2.1.10.5.1.1.2Columnx25AdmnInterfaceModeread-writemandatoryIdentifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation.
1.3.6.1.2.1.10.5.1.1.3Columnx25AdmnMaxActiveCircuitsread-writemandatoryThe maximum number of circuits this PLE can support; including PVCs.
1.3.6.1.2.1.10.5.1.1.4Columnx25AdmnPacketSequencingread-writemandatoryThe modulus of the packet sequence number space.
1.3.6.1.2.1.10.5.1.1.5Columnx25AdmnRestartTimerread-writemandatoryThe T20 restart timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.6Columnx25AdmnCallTimerread-writemandatoryThe T21 Call timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.7Columnx25AdmnResetTimerread-writemandatoryThe T22 Reset timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.8Columnx25AdmnClearTimerread-writemandatoryThe T23 Clear timer in milliseconds.
1.3.6.1.2.1.10.5.1.1.9Columnx25AdmnWindowTimerread-writemandatoryThe T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use.
1.3.6.1.2.1.10.5.1.1.10Columnx25AdmnDataRxmtTimerread-writemandatoryThe T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
1.3.6.1.2.1.10.5.1.1.11Columnx25AdmnInterruptTimerread-writemandatoryThe T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use.
1.3.6.1.2.1.10.5.1.1.12Columnx25AdmnRejectTimerread-writemandatoryThe T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
1.3.6.1.2.1.10.5.1.1.13Columnx25AdmnRegistrationRequestTimerread-writemandatoryThe T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
1.3.6.1.2.1.10.5.1.1.14Columnx25AdmnMinimumRecallTimerread-writemandatoryMinimum time interval between unsuccessful call attempts in milliseconds.
1.3.6.1.2.1.10.5.1.1.15Columnx25AdmnRestartCountread-writemandatoryThe R20 restart retransmission count.
1.3.6.1.2.1.10.5.1.1.16Columnx25AdmnResetCountread-writemandatoryThe r22 Reset retransmission count.
1.3.6.1.2.1.10.5.1.1.17Columnx25AdmnClearCountread-writemandatoryThe r23 Clear retransmission count.
1.3.6.1.2.1.10.5.1.1.18Columnx25AdmnDataRxmtCountread-writemandatoryThe R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use.
1.3.6.1.2.1.10.5.1.1.19Columnx25AdmnRejectCountread-writemandatoryThe R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use.
1.3.6.1.2.1.10.5.1.1.20Columnx25AdmnRegistrationRequestCountread-writemandatoryThe R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use.
1.3.6.1.2.1.10.5.1.1.21Columnx25AdmnNumberPVCsread-writemandatoryThe number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
1.3.6.1.2.1.10.5.1.1.22Columnx25AdmnDefCallParamIdread-writemandatoryThis identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE.
1.3.6.1.2.1.10.5.1.1.23Columnx25AdmnLocalAddressread-writemandatoryThe local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
1.3.6.1.2.1.10.5.1.1.24Columnx25AdmnProtocolVersionSupportedread-writemandatoryIdentifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion s…
1.3.6.1.2.1.10.5.2Tablex25OperTablenot-accessiblemandatoryThe operation parameters in use by the X.25 PLE.
1.3.6.1.2.1.10.5.2Nodex25ResetIf the PLE sends or receives a reset, the agent should send an x25Reset trap.
1.3.6.1.2.1.10.5.2.1Rowx25OperEntrynot-accessiblemandatoryEntries of x25OperTable.
1.3.6.1.2.1.10.5.2.1.1Columnx25OperIndexread-onlymandatoryThe ifIndex value for the X.25 interface.
1.3.6.1.2.1.10.5.2.1.2Columnx25OperInterfaceModeread-onlymandatoryIdentifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that neg…
1.3.6.1.2.1.10.5.2.1.3Columnx25OperMaxActiveCircuitsread-onlymandatoryMaximum number of circuits this PLE can support.
1.3.6.1.2.1.10.5.2.1.4Columnx25OperPacketSequencingread-onlymandatoryThe modulus of the packet sequence number space.
1.3.6.1.2.1.10.5.2.1.5Columnx25OperRestartTimerread-onlymandatoryThe T20 restart timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.6Columnx25OperCallTimerread-onlymandatoryThe T21 Call timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.7Columnx25OperResetTimerread-onlymandatoryThe T22 Reset timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.8Columnx25OperClearTimerread-onlymandatoryThe T23 Clear timer in milliseconds.
1.3.6.1.2.1.10.5.2.1.9Columnx25OperWindowTimerread-onlymandatoryThe T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use.
1.3.6.1.2.1.10.5.2.1.10Columnx25OperDataRxmtTimerread-onlymandatoryThe T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
1.3.6.1.2.1.10.5.2.1.11Columnx25OperInterruptTimerread-onlymandatoryThe T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used.
1.3.6.1.2.1.10.5.2.1.12Columnx25OperRejectTimerread-onlymandatoryThe T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
1.3.6.1.2.1.10.5.2.1.13Columnx25OperRegistrationRequestTimerread-onlymandatoryThe T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
1.3.6.1.2.1.10.5.2.1.14Columnx25OperMinimumRecallTimerread-onlymandatoryMinimum time interval between unsuccessful call attempts in milliseconds.
1.3.6.1.2.1.10.5.2.1.15Columnx25OperRestartCountread-onlymandatoryThe R20 restart retransmission count.
1.3.6.1.2.1.10.5.2.1.16Columnx25OperResetCountread-onlymandatoryThe r22 Reset retransmission count.
1.3.6.1.2.1.10.5.2.1.17Columnx25OperClearCountread-onlymandatoryThe r23 Clear retransmission count.
1.3.6.1.2.1.10.5.2.1.18Columnx25OperDataRxmtCountread-onlymandatoryThe R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use.
1.3.6.1.2.1.10.5.2.1.19Columnx25OperRejectCountread-onlymandatoryThe R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use.
1.3.6.1.2.1.10.5.2.1.20Columnx25OperRegistrationRequestCountread-onlymandatoryThe R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use.
1.3.6.1.2.1.10.5.2.1.21Columnx25OperNumberPVCsread-onlymandatoryThe number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
1.3.6.1.2.1.10.5.2.1.22Columnx25OperDefCallParamIdread-onlymandatoryThis identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE.
1.3.6.1.2.1.10.5.2.1.23Columnx25OperLocalAddressread-onlymandatoryThe local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
1.3.6.1.2.1.10.5.2.1.24Columnx25OperDataLinkIdread-onlymandatoryThis identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE.
1.3.6.1.2.1.10.5.2.1.25Columnx25OperProtocolVersionSupportedread-onlymandatoryIdentifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
1.3.6.1.2.1.10.5.3Tablex25StatTablenot-accessiblemandatoryStatistics information about this X.25 PLE.
1.3.6.1.2.1.10.5.3.1Rowx25StatEntrynot-accessiblemandatoryEntries of the x25StatTable.
1.3.6.1.2.1.10.5.3.1.1Columnx25StatIndexread-onlymandatoryThe ifIndex value for the X.25 interface.
1.3.6.1.2.1.10.5.3.1.2Columnx25StatInCallsread-onlymandatoryThe number of incoming calls received.
1.3.6.1.2.1.10.5.3.1.3Columnx25StatInCallRefusalsread-onlymandatoryThe number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast …
1.3.6.1.2.1.10.5.3.1.4Columnx25StatInProviderInitiatedClearsread-onlymandatoryThe number of clear requests with a cause code other than DTE initiated.
1.3.6.1.2.1.10.5.3.1.5Columnx25StatInRemotelyInitiatedResetsread-onlymandatoryThe number of reset requests received with cause code DTE initiated.
1.3.6.1.2.1.10.5.3.1.6Columnx25StatInProviderInitiatedResetsread-onlymandatoryThe number of reset requests received with cause code other than DTE initiated.
1.3.6.1.2.1.10.5.3.1.7Columnx25StatInRestartsread-onlymandatoryThe number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE inter…
1.3.6.1.2.1.10.5.3.1.8Columnx25StatInDataPacketsread-onlymandatoryThe number of data packets received.
1.3.6.1.2.1.10.5.3.1.9Columnx25StatInAccusedOfProtocolErrorsread-onlymandatoryThe number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets.
1.3.6.1.2.1.10.5.3.1.10Columnx25StatInInterruptsread-onlymandatoryThe number of interrupt packets received by the PLE or over the PVC/VC.
1.3.6.1.2.1.10.5.3.1.11Columnx25StatOutCallAttemptsread-onlymandatoryThe number of calls attempted.
1.3.6.1.2.1.10.5.3.1.12Columnx25StatOutCallFailuresread-onlymandatoryThe number of call attempts which failed. This includes calls that were cleared because of restrictive fast select.
1.3.6.1.2.1.10.5.3.1.13Columnx25StatOutInterruptsread-onlymandatoryThe number of interrupt packets send by the PLE or over the PVC/VC.
1.3.6.1.2.1.10.5.3.1.14Columnx25StatOutDataPacketsread-onlymandatoryThe number of data packets sent by this PLE.
1.3.6.1.2.1.10.5.3.1.15Columnx25StatOutgoingCircuitsread-onlymandatoryThe number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
1.3.6.1.2.1.10.5.3.1.16Columnx25StatIncomingCircuitsread-onlymandatoryThe number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs.
1.3.6.1.2.1.10.5.3.1.17Columnx25StatTwowayCircuitsread-onlymandatoryThe number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
1.3.6.1.2.1.10.5.3.1.18Columnx25StatRestartTimeoutsread-onlymandatoryThe number of times the T20 restart timer expired.
1.3.6.1.2.1.10.5.3.1.19Columnx25StatCallTimeoutsread-onlymandatoryThe number of times the T21 call timer expired.
1.3.6.1.2.1.10.5.3.1.20Columnx25StatResetTimeoutsread-onlymandatoryThe number of times the T22 reset timer expired.
1.3.6.1.2.1.10.5.3.1.21Columnx25StatClearTimeoutsread-onlymandatoryThe number of times the T23 clear timer expired.
1.3.6.1.2.1.10.5.3.1.22Columnx25StatDataRxmtTimeoutsread-onlymandatoryThe number of times the T25 data timer expired.
1.3.6.1.2.1.10.5.3.1.23Columnx25StatInterruptTimeoutsread-onlymandatoryThe number of times the T26 interrupt timer expired.
1.3.6.1.2.1.10.5.3.1.24Columnx25StatRetryCountExceededsread-onlymandatoryThe number of times a retry counter was exhausted.
1.3.6.1.2.1.10.5.3.1.25Columnx25StatClearCountExceededsread-onlymandatoryThe number of times the R23 clear count was exceeded.
1.3.6.1.2.1.10.5.4Tablex25ChannelTablenot-accessiblemandatoryThese objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after …
1.3.6.1.2.1.10.5.4.1Rowx25ChannelEntrynot-accessiblemandatoryEntries of x25ChannelTable.
1.3.6.1.2.1.10.5.4.1.1Columnx25ChannelIndexread-onlymandatoryThe ifIndex value for the X.25 Interface.
1.3.6.1.2.1.10.5.4.1.2Columnx25ChannelLICread-writemandatoryLowest Incoming channel.
1.3.6.1.2.1.10.5.4.1.3Columnx25ChannelHICread-writemandatoryHighest Incoming channel. A value of zero indicates no channels in this range.
1.3.6.1.2.1.10.5.4.1.4Columnx25ChannelLTCread-writemandatoryLowest Two-way channel.
1.3.6.1.2.1.10.5.4.1.5Columnx25ChannelHTCread-writemandatoryHighest Two-way channel. A value of zero indicates no channels in this range.
1.3.6.1.2.1.10.5.4.1.6Columnx25ChannelLOCread-writemandatoryLowest outgoing channel.
1.3.6.1.2.1.10.5.4.1.7Columnx25ChannelHOCread-writemandatoryHighest outgoing channel. A value of zero indicates no channels in this range.
1.3.6.1.2.1.10.5.5Tablex25CircuitTablenot-accessiblemandatoryThese objects contain general information about a specific circuit of an X.25 PLE.
1.3.6.1.2.1.10.5.5.1Rowx25CircuitEntrynot-accessiblemandatoryEntries of x25CircuitTable.
1.3.6.1.2.1.10.5.5.1.1Columnx25CircuitIndexread-onlymandatoryThe ifIndex value for the X.25 Interface.
1.3.6.1.2.1.10.5.5.1.2Columnx25CircuitChannelread-onlymandatoryThe channel number for this circuit.
1.3.6.1.2.1.10.5.5.1.3Columnx25CircuitStatusread-writemandatoryThis object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An ins…
1.3.6.1.2.1.10.5.5.1.4Columnx25CircuitEstablishTimeread-onlymandatoryThe value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs…
1.3.6.1.2.1.10.5.5.1.5Columnx25CircuitDirectionread-writemandatoryThe direction of the call that established this circuit.
1.3.6.1.2.1.10.5.5.1.6Columnx25CircuitInOctetsread-onlymandatoryThe number of octets of user data delivered to upper layer.
1.3.6.1.2.1.10.5.5.1.7Columnx25CircuitInPdusread-onlymandatoryThe number of PDUs received for this circuit.
1.3.6.1.2.1.10.5.5.1.8Columnx25CircuitInRemotelyInitiatedResetsread-onlymandatoryThe number of Resets received for this circuit with cause code of DTE initiated.
1.3.6.1.2.1.10.5.5.1.9Columnx25CircuitInProviderInitiatedResetsread-onlymandatoryThe number of Resets received for this circuit with cause code other than DTE initiated.
1.3.6.1.2.1.10.5.5.1.10Columnx25CircuitInInterruptsread-onlymandatoryThe number of interrupt packets received for this circuit.
1.3.6.1.2.1.10.5.5.1.11Columnx25CircuitOutOctetsread-onlymandatoryThe number of octets of user data sent for this circuit.
1.3.6.1.2.1.10.5.5.1.12Columnx25CircuitOutPdusread-onlymandatoryThe number of PDUs sent for this circuit.
1.3.6.1.2.1.10.5.5.1.13Columnx25CircuitOutInterruptsread-onlymandatoryThe number of interrupt packets sent on this circuit.
1.3.6.1.2.1.10.5.5.1.14Columnx25CircuitDataRetransmissionTimeoutsread-onlymandatoryThe number of times the T25 data retransmission timer expired for this circuit.
1.3.6.1.2.1.10.5.5.1.15Columnx25CircuitResetTimeoutsread-onlymandatoryThe number of times the T22 reset timer expired for this circuit.
1.3.6.1.2.1.10.5.5.1.16Columnx25CircuitInterruptTimeoutsread-onlymandatoryThe number of times the T26 Interrupt timer expired for this circuit.
1.3.6.1.2.1.10.5.5.1.17Columnx25CircuitCallParamIdread-writemandatoryThis identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The ent…
1.3.6.1.2.1.10.5.5.1.18Columnx25CircuitCalledDteAddressread-writemandatoryFor incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packe…
1.3.6.1.2.1.10.5.5.1.19Columnx25CircuitCallingDteAddressread-writemandatoryFor incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation pac…
1.3.6.1.2.1.10.5.5.1.20Columnx25CircuitOriginallyCalledAddressread-writemandatoryFor incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it …
1.3.6.1.2.1.10.5.5.1.21Columnx25CircuitDescrread-writemandatoryA descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of…
1.3.6.1.2.1.10.5.6Scalarx25ClearedCircuitEntriesRequestedread-writemandatoryThe requested number of entries for the agent to keep in the x25ClearedCircuit table.
1.3.6.1.2.1.10.5.7Scalarx25ClearedCircuitEntriesGrantedread-onlymandatoryThe actual number of entries the agent will keep in the x25ClearedCircuit Table.
1.3.6.1.2.1.10.5.8Tablex25ClearedCircuitTablenot-accessiblemandatoryA table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet cont…
1.3.6.1.2.1.10.5.8.1Rowx25ClearedCircuitEntrynot-accessiblemandatoryInformation about a cleared circuit.
1.3.6.1.2.1.10.5.8.1.1Columnx25ClearedCircuitIndexread-onlymandatoryAn index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each n…
1.3.6.1.2.1.10.5.8.1.2Columnx25ClearedCircuitPleIndexread-onlymandatoryThe value of ifIndex for the PLE which cleared the circuit that created the entry.
1.3.6.1.2.1.10.5.8.1.3Columnx25ClearedCircuitTimeEstablishedread-onlymandatoryThe value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit.
1.3.6.1.2.1.10.5.8.1.4Columnx25ClearedCircuitTimeClearedread-onlymandatoryThe value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely…
1.3.6.1.2.1.10.5.8.1.5Columnx25ClearedCircuitChannelread-onlymandatoryThe channel number for the circuit that was cleared.
1.3.6.1.2.1.10.5.8.1.6Columnx25ClearedCircuitClearingCauseread-onlymandatoryThe Clearing Cause from the clear request or clear indication packet that cleared the circuit.
1.3.6.1.2.1.10.5.8.1.7Columnx25ClearedCircuitDiagnosticCoderead-onlymandatoryThe Diagnostic Code from the clear request or clear indication packet that cleared the circuit.
1.3.6.1.2.1.10.5.8.1.8Columnx25ClearedCircuitInPdusread-onlymandatoryThe number of PDUs received on the circuit.
1.3.6.1.2.1.10.5.8.1.9Columnx25ClearedCircuitOutPdusread-onlymandatoryThe number of PDUs transmitted on the circuit.
1.3.6.1.2.1.10.5.8.1.10Columnx25ClearedCircuitCalledAddressread-onlymandatoryThe called address from the cleared circuit.
1.3.6.1.2.1.10.5.8.1.11Columnx25ClearedCircuitCallingAddressread-onlymandatoryThe calling address from the cleared circuit.
1.3.6.1.2.1.10.5.8.1.12Columnx25ClearedCircuitClearFacilitiesread-onlymandatoryThe facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present.
1.3.6.1.2.1.10.5.9Tablex25CallParmTablenot-accessiblemandatoryThese objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of thes…
1.3.6.1.2.1.10.5.9.1Rowx25CallParmEntrynot-accessiblemandatoryEntries of x25CallParmTable.
1.3.6.1.2.1.10.5.9.1.1Columnx25CallParmIndexread-onlymandatoryA value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossi…
1.3.6.1.2.1.10.5.9.1.2Columnx25CallParmStatusread-writemandatoryThe status of this call parameter entry. See RFC 1271 for details of usage.
1.3.6.1.2.1.10.5.9.1.3Columnx25CallParmRefCountread-onlymandatoryThe number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value o…
1.3.6.1.2.1.10.5.9.1.4Columnx25CallParmInPacketSizeread-writemandatoryThe maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a de…
1.3.6.1.2.1.10.5.9.1.5Columnx25CallParmOutPacketSizeread-writemandatoryThe maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means…
1.3.6.1.2.1.10.5.9.1.6Columnx25CallParmInWindowSizeread-writemandatoryThe receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
1.3.6.1.2.1.10.5.9.1.7Columnx25CallParmOutWindowSizeread-writemandatoryThe transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
1.3.6.1.2.1.10.5.9.1.8Columnx25CallParmAcceptReverseChargingread-writemandatoryAn enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is o…
1.3.6.1.2.1.10.5.9.1.9Columnx25CallParmProposeReverseChargingread-writemandatoryAn enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default…
1.3.6.1.2.1.10.5.9.1.10Columnx25CallParmFastSelectread-writemandatoryExpresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect.…
1.3.6.1.2.1.10.5.9.1.11Columnx25CallParmInThruPutClasSizeread-writemandatoryThe incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone…
1.3.6.1.2.1.10.5.9.1.12Columnx25CallParmOutThruPutClasSizeread-writemandatoryThe outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tc…
1.3.6.1.2.1.10.5.9.1.13Columnx25CallParmCugread-writemandatoryThe Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility request…
1.3.6.1.2.1.10.5.9.1.14Columnx25CallParmCugoaread-writemandatoryThe Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three cont…
1.3.6.1.2.1.10.5.9.1.15Columnx25CallParmBcugread-writemandatoryThe Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characte…
1.3.6.1.2.1.10.5.9.1.16Columnx25CallParmNuiread-writemandatoryThe Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero leng…
1.3.6.1.2.1.10.5.9.1.17Columnx25CallParmChargingInforead-writemandatoryThe charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use no…
1.3.6.1.2.1.10.5.9.1.18Columnx25CallParmRpoaread-writemandatoryThe RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 char…
1.3.6.1.2.1.10.5.9.1.19Columnx25CallParmTrnstDlyread-writemandatoryThe Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (t…
1.3.6.1.2.1.10.5.9.1.20Columnx25CallParmCallingExtread-writemandatoryThe Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be con…
1.3.6.1.2.1.10.5.9.1.21Columnx25CallParmCalledExtread-writemandatoryThe Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be conv…
1.3.6.1.2.1.10.5.9.1.22Columnx25CallParmInMinThuPutClsread-writemandatoryThe minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indi…
1.3.6.1.2.1.10.5.9.1.23Columnx25CallParmOutMinThuPutClsread-writemandatoryThe minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 ind…
1.3.6.1.2.1.10.5.9.1.24Columnx25CallParmEndTrnsDlyread-writemandatoryThe End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An…
1.3.6.1.2.1.10.5.9.1.25Columnx25CallParmPriorityread-writemandatoryThe priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requeste…
1.3.6.1.2.1.10.5.9.1.26Columnx25CallParmProtectionread-writemandatoryA string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the p…
1.3.6.1.2.1.10.5.9.1.27Columnx25CallParmExptDataread-writemandatoryThe Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not ha…
1.3.6.1.2.1.10.5.9.1.28Columnx25CallParmUserDataread-writemandatoryThe call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call…
1.3.6.1.2.1.10.5.9.1.29Columnx25CallParmCallingNetworkFacilitiesread-writemandatoryThe calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code…
1.3.6.1.2.1.10.5.9.1.30Columnx25CallParmCalledNetworkFacilitiesread-writemandatoryThe called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code.…
1.3.6.1.2.1.10.5.10Nodex25ProtocolVersion
1.3.6.1.2.1.10.5.10.1Nodex25protocolCcittV1976
1.3.6.1.2.1.10.5.10.2Nodex25protocolCcittV1980
1.3.6.1.2.1.10.5.10.3Nodex25protocolCcittV1984
1.3.6.1.2.1.10.5.10.4Nodex25protocolCcittV1988
1.3.6.1.2.1.10.5.10.5Nodex25protocolIso8208V1987
1.3.6.1.2.1.10.5.10.6Nodex25protocolIso8208V1989