Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter Gauge TimeTicks |
| RFC1213-MIB | DisplayString transmission |
| RFC1271-MIB | EntryStatus |
| RFC1381-MIB | IfIndexType PositiveInteger |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.10.5 | Nodex25 | |||
| 1.3.6.1.2.1.10.5.1 | Tablex25AdmnTable | not-accessible | mandatory | This table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have correspondi… |
| 1.3.6.1.2.1.10.5.1 | Nodex25Restart | This trap means the X.25 PLE sent or received a restart packet. The restart that brings up the link should not send a x25Restart trap so the interface should s… | ||
| 1.3.6.1.2.1.10.5.1.1 | Rowx25AdmnEntry | not-accessible | mandatory | Entries of x25AdmnTable. |
| 1.3.6.1.2.1.10.5.1.1.1 | Columnx25AdmnIndex | read-only | mandatory | The ifIndex value for the X.25 Interface. |
| 1.3.6.1.2.1.10.5.1.1.2 | Columnx25AdmnInterfaceMode | read-write | mandatory | Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation. |
| 1.3.6.1.2.1.10.5.1.1.3 | Columnx25AdmnMaxActiveCircuits | read-write | mandatory | The maximum number of circuits this PLE can support; including PVCs. |
| 1.3.6.1.2.1.10.5.1.1.4 | Columnx25AdmnPacketSequencing | read-write | mandatory | The modulus of the packet sequence number space. |
| 1.3.6.1.2.1.10.5.1.1.5 | Columnx25AdmnRestartTimer | read-write | mandatory | The T20 restart timer in milliseconds. |
| 1.3.6.1.2.1.10.5.1.1.6 | Columnx25AdmnCallTimer | read-write | mandatory | The T21 Call timer in milliseconds. |
| 1.3.6.1.2.1.10.5.1.1.7 | Columnx25AdmnResetTimer | read-write | mandatory | The T22 Reset timer in milliseconds. |
| 1.3.6.1.2.1.10.5.1.1.8 | Columnx25AdmnClearTimer | read-write | mandatory | The T23 Clear timer in milliseconds. |
| 1.3.6.1.2.1.10.5.1.1.9 | Columnx25AdmnWindowTimer | read-write | mandatory | The T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use. |
| 1.3.6.1.2.1.10.5.1.1.10 | Columnx25AdmnDataRxmtTimer | read-write | mandatory | The T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use. |
| 1.3.6.1.2.1.10.5.1.1.11 | Columnx25AdmnInterruptTimer | read-write | mandatory | The T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use. |
| 1.3.6.1.2.1.10.5.1.1.12 | Columnx25AdmnRejectTimer | read-write | mandatory | The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use. |
| 1.3.6.1.2.1.10.5.1.1.13 | Columnx25AdmnRegistrationRequestTimer | read-write | mandatory | The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use. |
| 1.3.6.1.2.1.10.5.1.1.14 | Columnx25AdmnMinimumRecallTimer | read-write | mandatory | Minimum time interval between unsuccessful call attempts in milliseconds. |
| 1.3.6.1.2.1.10.5.1.1.15 | Columnx25AdmnRestartCount | read-write | mandatory | The R20 restart retransmission count. |
| 1.3.6.1.2.1.10.5.1.1.16 | Columnx25AdmnResetCount | read-write | mandatory | The r22 Reset retransmission count. |
| 1.3.6.1.2.1.10.5.1.1.17 | Columnx25AdmnClearCount | read-write | mandatory | The r23 Clear retransmission count. |
| 1.3.6.1.2.1.10.5.1.1.18 | Columnx25AdmnDataRxmtCount | read-write | mandatory | The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use. |
| 1.3.6.1.2.1.10.5.1.1.19 | Columnx25AdmnRejectCount | read-write | mandatory | The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use. |
| 1.3.6.1.2.1.10.5.1.1.20 | Columnx25AdmnRegistrationRequestCount | read-write | mandatory | The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use. |
| 1.3.6.1.2.1.10.5.1.1.21 | Columnx25AdmnNumberPVCs | read-write | mandatory | The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number. |
| 1.3.6.1.2.1.10.5.1.1.22 | Columnx25AdmnDefCallParamId | read-write | mandatory | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE. |
| 1.3.6.1.2.1.10.5.1.1.23 | Columnx25AdmnLocalAddress | read-write | mandatory | The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs. |
| 1.3.6.1.2.1.10.5.1.1.24 | Columnx25AdmnProtocolVersionSupported | read-write | mandatory | Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion s… |
| 1.3.6.1.2.1.10.5.2 | Tablex25OperTable | not-accessible | mandatory | The operation parameters in use by the X.25 PLE. |
| 1.3.6.1.2.1.10.5.2 | Nodex25Reset | If the PLE sends or receives a reset, the agent should send an x25Reset trap. | ||
| 1.3.6.1.2.1.10.5.2.1 | Rowx25OperEntry | not-accessible | mandatory | Entries of x25OperTable. |
| 1.3.6.1.2.1.10.5.2.1.1 | Columnx25OperIndex | read-only | mandatory | The ifIndex value for the X.25 interface. |
| 1.3.6.1.2.1.10.5.2.1.2 | Columnx25OperInterfaceMode | read-only | mandatory | Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that neg… |
| 1.3.6.1.2.1.10.5.2.1.3 | Columnx25OperMaxActiveCircuits | read-only | mandatory | Maximum number of circuits this PLE can support. |
| 1.3.6.1.2.1.10.5.2.1.4 | Columnx25OperPacketSequencing | read-only | mandatory | The modulus of the packet sequence number space. |
| 1.3.6.1.2.1.10.5.2.1.5 | Columnx25OperRestartTimer | read-only | mandatory | The T20 restart timer in milliseconds. |
| 1.3.6.1.2.1.10.5.2.1.6 | Columnx25OperCallTimer | read-only | mandatory | The T21 Call timer in milliseconds. |
| 1.3.6.1.2.1.10.5.2.1.7 | Columnx25OperResetTimer | read-only | mandatory | The T22 Reset timer in milliseconds. |
| 1.3.6.1.2.1.10.5.2.1.8 | Columnx25OperClearTimer | read-only | mandatory | The T23 Clear timer in milliseconds. |
| 1.3.6.1.2.1.10.5.2.1.9 | Columnx25OperWindowTimer | read-only | mandatory | The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use. |
| 1.3.6.1.2.1.10.5.2.1.10 | Columnx25OperDataRxmtTimer | read-only | mandatory | The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use. |
| 1.3.6.1.2.1.10.5.2.1.11 | Columnx25OperInterruptTimer | read-only | mandatory | The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used. |
| 1.3.6.1.2.1.10.5.2.1.12 | Columnx25OperRejectTimer | read-only | mandatory | The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use. |
| 1.3.6.1.2.1.10.5.2.1.13 | Columnx25OperRegistrationRequestTimer | read-only | mandatory | The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use. |
| 1.3.6.1.2.1.10.5.2.1.14 | Columnx25OperMinimumRecallTimer | read-only | mandatory | Minimum time interval between unsuccessful call attempts in milliseconds. |
| 1.3.6.1.2.1.10.5.2.1.15 | Columnx25OperRestartCount | read-only | mandatory | The R20 restart retransmission count. |
| 1.3.6.1.2.1.10.5.2.1.16 | Columnx25OperResetCount | read-only | mandatory | The r22 Reset retransmission count. |
| 1.3.6.1.2.1.10.5.2.1.17 | Columnx25OperClearCount | read-only | mandatory | The r23 Clear retransmission count. |
| 1.3.6.1.2.1.10.5.2.1.18 | Columnx25OperDataRxmtCount | read-only | mandatory | The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use. |
| 1.3.6.1.2.1.10.5.2.1.19 | Columnx25OperRejectCount | read-only | mandatory | The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use. |
| 1.3.6.1.2.1.10.5.2.1.20 | Columnx25OperRegistrationRequestCount | read-only | mandatory | The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use. |
| 1.3.6.1.2.1.10.5.2.1.21 | Columnx25OperNumberPVCs | read-only | mandatory | The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number. |
| 1.3.6.1.2.1.10.5.2.1.22 | Columnx25OperDefCallParamId | read-only | mandatory | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE. |
| 1.3.6.1.2.1.10.5.2.1.23 | Columnx25OperLocalAddress | read-only | mandatory | The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs. |
| 1.3.6.1.2.1.10.5.2.1.24 | Columnx25OperDataLinkId | read-only | mandatory | This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE. |
| 1.3.6.1.2.1.10.5.2.1.25 | Columnx25OperProtocolVersionSupported | read-only | mandatory | Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree. |
| 1.3.6.1.2.1.10.5.3 | Tablex25StatTable | not-accessible | mandatory | Statistics information about this X.25 PLE. |
| 1.3.6.1.2.1.10.5.3.1 | Rowx25StatEntry | not-accessible | mandatory | Entries of the x25StatTable. |
| 1.3.6.1.2.1.10.5.3.1.1 | Columnx25StatIndex | read-only | mandatory | The ifIndex value for the X.25 interface. |
| 1.3.6.1.2.1.10.5.3.1.2 | Columnx25StatInCalls | read-only | mandatory | The number of incoming calls received. |
| 1.3.6.1.2.1.10.5.3.1.3 | Columnx25StatInCallRefusals | read-only | mandatory | The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast … |
| 1.3.6.1.2.1.10.5.3.1.4 | Columnx25StatInProviderInitiatedClears | read-only | mandatory | The number of clear requests with a cause code other than DTE initiated. |
| 1.3.6.1.2.1.10.5.3.1.5 | Columnx25StatInRemotelyInitiatedResets | read-only | mandatory | The number of reset requests received with cause code DTE initiated. |
| 1.3.6.1.2.1.10.5.3.1.6 | Columnx25StatInProviderInitiatedResets | read-only | mandatory | The number of reset requests received with cause code other than DTE initiated. |
| 1.3.6.1.2.1.10.5.3.1.7 | Columnx25StatInRestarts | read-only | mandatory | The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE inter… |
| 1.3.6.1.2.1.10.5.3.1.8 | Columnx25StatInDataPackets | read-only | mandatory | The number of data packets received. |
| 1.3.6.1.2.1.10.5.3.1.9 | Columnx25StatInAccusedOfProtocolErrors | read-only | mandatory | The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets. |
| 1.3.6.1.2.1.10.5.3.1.10 | Columnx25StatInInterrupts | read-only | mandatory | The number of interrupt packets received by the PLE or over the PVC/VC. |
| 1.3.6.1.2.1.10.5.3.1.11 | Columnx25StatOutCallAttempts | read-only | mandatory | The number of calls attempted. |
| 1.3.6.1.2.1.10.5.3.1.12 | Columnx25StatOutCallFailures | read-only | mandatory | The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select. |
| 1.3.6.1.2.1.10.5.3.1.13 | Columnx25StatOutInterrupts | read-only | mandatory | The number of interrupt packets send by the PLE or over the PVC/VC. |
| 1.3.6.1.2.1.10.5.3.1.14 | Columnx25StatOutDataPackets | read-only | mandatory | The number of data packets sent by this PLE. |
| 1.3.6.1.2.1.10.5.3.1.15 | Columnx25StatOutgoingCircuits | read-only | mandatory | The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs. |
| 1.3.6.1.2.1.10.5.3.1.16 | Columnx25StatIncomingCircuits | read-only | mandatory | The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs. |
| 1.3.6.1.2.1.10.5.3.1.17 | Columnx25StatTwowayCircuits | read-only | mandatory | The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs. |
| 1.3.6.1.2.1.10.5.3.1.18 | Columnx25StatRestartTimeouts | read-only | mandatory | The number of times the T20 restart timer expired. |
| 1.3.6.1.2.1.10.5.3.1.19 | Columnx25StatCallTimeouts | read-only | mandatory | The number of times the T21 call timer expired. |
| 1.3.6.1.2.1.10.5.3.1.20 | Columnx25StatResetTimeouts | read-only | mandatory | The number of times the T22 reset timer expired. |
| 1.3.6.1.2.1.10.5.3.1.21 | Columnx25StatClearTimeouts | read-only | mandatory | The number of times the T23 clear timer expired. |
| 1.3.6.1.2.1.10.5.3.1.22 | Columnx25StatDataRxmtTimeouts | read-only | mandatory | The number of times the T25 data timer expired. |
| 1.3.6.1.2.1.10.5.3.1.23 | Columnx25StatInterruptTimeouts | read-only | mandatory | The number of times the T26 interrupt timer expired. |
| 1.3.6.1.2.1.10.5.3.1.24 | Columnx25StatRetryCountExceededs | read-only | mandatory | The number of times a retry counter was exhausted. |
| 1.3.6.1.2.1.10.5.3.1.25 | Columnx25StatClearCountExceededs | read-only | mandatory | The number of times the R23 clear count was exceeded. |
| 1.3.6.1.2.1.10.5.4 | Tablex25ChannelTable | not-accessible | mandatory | These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after … |
| 1.3.6.1.2.1.10.5.4.1 | Rowx25ChannelEntry | not-accessible | mandatory | Entries of x25ChannelTable. |
| 1.3.6.1.2.1.10.5.4.1.1 | Columnx25ChannelIndex | read-only | mandatory | The ifIndex value for the X.25 Interface. |
| 1.3.6.1.2.1.10.5.4.1.2 | Columnx25ChannelLIC | read-write | mandatory | Lowest Incoming channel. |
| 1.3.6.1.2.1.10.5.4.1.3 | Columnx25ChannelHIC | read-write | mandatory | Highest Incoming channel. A value of zero indicates no channels in this range. |
| 1.3.6.1.2.1.10.5.4.1.4 | Columnx25ChannelLTC | read-write | mandatory | Lowest Two-way channel. |
| 1.3.6.1.2.1.10.5.4.1.5 | Columnx25ChannelHTC | read-write | mandatory | Highest Two-way channel. A value of zero indicates no channels in this range. |
| 1.3.6.1.2.1.10.5.4.1.6 | Columnx25ChannelLOC | read-write | mandatory | Lowest outgoing channel. |
| 1.3.6.1.2.1.10.5.4.1.7 | Columnx25ChannelHOC | read-write | mandatory | Highest outgoing channel. A value of zero indicates no channels in this range. |
| 1.3.6.1.2.1.10.5.5 | Tablex25CircuitTable | not-accessible | mandatory | These objects contain general information about a specific circuit of an X.25 PLE. |
| 1.3.6.1.2.1.10.5.5.1 | Rowx25CircuitEntry | not-accessible | mandatory | Entries of x25CircuitTable. |
| 1.3.6.1.2.1.10.5.5.1.1 | Columnx25CircuitIndex | read-only | mandatory | The ifIndex value for the X.25 Interface. |
| 1.3.6.1.2.1.10.5.5.1.2 | Columnx25CircuitChannel | read-only | mandatory | The channel number for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.3 | Columnx25CircuitStatus | read-write | mandatory | This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An ins… |
| 1.3.6.1.2.1.10.5.5.1.4 | Columnx25CircuitEstablishTime | read-only | mandatory | The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs… |
| 1.3.6.1.2.1.10.5.5.1.5 | Columnx25CircuitDirection | read-write | mandatory | The direction of the call that established this circuit. |
| 1.3.6.1.2.1.10.5.5.1.6 | Columnx25CircuitInOctets | read-only | mandatory | The number of octets of user data delivered to upper layer. |
| 1.3.6.1.2.1.10.5.5.1.7 | Columnx25CircuitInPdus | read-only | mandatory | The number of PDUs received for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.8 | Columnx25CircuitInRemotelyInitiatedResets | read-only | mandatory | The number of Resets received for this circuit with cause code of DTE initiated. |
| 1.3.6.1.2.1.10.5.5.1.9 | Columnx25CircuitInProviderInitiatedResets | read-only | mandatory | The number of Resets received for this circuit with cause code other than DTE initiated. |
| 1.3.6.1.2.1.10.5.5.1.10 | Columnx25CircuitInInterrupts | read-only | mandatory | The number of interrupt packets received for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.11 | Columnx25CircuitOutOctets | read-only | mandatory | The number of octets of user data sent for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.12 | Columnx25CircuitOutPdus | read-only | mandatory | The number of PDUs sent for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.13 | Columnx25CircuitOutInterrupts | read-only | mandatory | The number of interrupt packets sent on this circuit. |
| 1.3.6.1.2.1.10.5.5.1.14 | Columnx25CircuitDataRetransmissionTimeouts | read-only | mandatory | The number of times the T25 data retransmission timer expired for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.15 | Columnx25CircuitResetTimeouts | read-only | mandatory | The number of times the T22 reset timer expired for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.16 | Columnx25CircuitInterruptTimeouts | read-only | mandatory | The number of times the T26 Interrupt timer expired for this circuit. |
| 1.3.6.1.2.1.10.5.5.1.17 | Columnx25CircuitCallParamId | read-write | mandatory | This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The ent… |
| 1.3.6.1.2.1.10.5.5.1.18 | Columnx25CircuitCalledDteAddress | read-write | mandatory | For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packe… |
| 1.3.6.1.2.1.10.5.5.1.19 | Columnx25CircuitCallingDteAddress | read-write | mandatory | For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation pac… |
| 1.3.6.1.2.1.10.5.5.1.20 | Columnx25CircuitOriginallyCalledAddress | read-write | mandatory | For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it … |
| 1.3.6.1.2.1.10.5.5.1.21 | Columnx25CircuitDescr | read-write | mandatory | A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of… |
| 1.3.6.1.2.1.10.5.6 | Scalarx25ClearedCircuitEntriesRequested | read-write | mandatory | The requested number of entries for the agent to keep in the x25ClearedCircuit table. |
| 1.3.6.1.2.1.10.5.7 | Scalarx25ClearedCircuitEntriesGranted | read-only | mandatory | The actual number of entries the agent will keep in the x25ClearedCircuit Table. |
| 1.3.6.1.2.1.10.5.8 | Tablex25ClearedCircuitTable | not-accessible | mandatory | A table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet cont… |
| 1.3.6.1.2.1.10.5.8.1 | Rowx25ClearedCircuitEntry | not-accessible | mandatory | Information about a cleared circuit. |
| 1.3.6.1.2.1.10.5.8.1.1 | Columnx25ClearedCircuitIndex | read-only | mandatory | An index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each n… |
| 1.3.6.1.2.1.10.5.8.1.2 | Columnx25ClearedCircuitPleIndex | read-only | mandatory | The value of ifIndex for the PLE which cleared the circuit that created the entry. |
| 1.3.6.1.2.1.10.5.8.1.3 | Columnx25ClearedCircuitTimeEstablished | read-only | mandatory | The value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit. |
| 1.3.6.1.2.1.10.5.8.1.4 | Columnx25ClearedCircuitTimeCleared | read-only | mandatory | The value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely… |
| 1.3.6.1.2.1.10.5.8.1.5 | Columnx25ClearedCircuitChannel | read-only | mandatory | The channel number for the circuit that was cleared. |
| 1.3.6.1.2.1.10.5.8.1.6 | Columnx25ClearedCircuitClearingCause | read-only | mandatory | The Clearing Cause from the clear request or clear indication packet that cleared the circuit. |
| 1.3.6.1.2.1.10.5.8.1.7 | Columnx25ClearedCircuitDiagnosticCode | read-only | mandatory | The Diagnostic Code from the clear request or clear indication packet that cleared the circuit. |
| 1.3.6.1.2.1.10.5.8.1.8 | Columnx25ClearedCircuitInPdus | read-only | mandatory | The number of PDUs received on the circuit. |
| 1.3.6.1.2.1.10.5.8.1.9 | Columnx25ClearedCircuitOutPdus | read-only | mandatory | The number of PDUs transmitted on the circuit. |
| 1.3.6.1.2.1.10.5.8.1.10 | Columnx25ClearedCircuitCalledAddress | read-only | mandatory | The called address from the cleared circuit. |
| 1.3.6.1.2.1.10.5.8.1.11 | Columnx25ClearedCircuitCallingAddress | read-only | mandatory | The calling address from the cleared circuit. |
| 1.3.6.1.2.1.10.5.8.1.12 | Columnx25ClearedCircuitClearFacilities | read-only | mandatory | The facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present. |
| 1.3.6.1.2.1.10.5.9 | Tablex25CallParmTable | not-accessible | mandatory | These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of thes… |
| 1.3.6.1.2.1.10.5.9.1 | Rowx25CallParmEntry | not-accessible | mandatory | Entries of x25CallParmTable. |
| 1.3.6.1.2.1.10.5.9.1.1 | Columnx25CallParmIndex | read-only | mandatory | A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossi… |
| 1.3.6.1.2.1.10.5.9.1.2 | Columnx25CallParmStatus | read-write | mandatory | The status of this call parameter entry. See RFC 1271 for details of usage. |
| 1.3.6.1.2.1.10.5.9.1.3 | Columnx25CallParmRefCount | read-only | mandatory | The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value o… |
| 1.3.6.1.2.1.10.5.9.1.4 | Columnx25CallParmInPacketSize | read-write | mandatory | The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a de… |
| 1.3.6.1.2.1.10.5.9.1.5 | Columnx25CallParmOutPacketSize | read-write | mandatory | The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means… |
| 1.3.6.1.2.1.10.5.9.1.6 | Columnx25CallParmInWindowSize | read-write | mandatory | The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| 1.3.6.1.2.1.10.5.9.1.7 | Columnx25CallParmOutWindowSize | read-write | mandatory | The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2. |
| 1.3.6.1.2.1.10.5.9.1.8 | Columnx25CallParmAcceptReverseCharging | read-write | mandatory | An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is o… |
| 1.3.6.1.2.1.10.5.9.1.9 | Columnx25CallParmProposeReverseCharging | read-write | mandatory | An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default… |
| 1.3.6.1.2.1.10.5.9.1.10 | Columnx25CallParmFastSelect | read-write | mandatory | Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect.… |
| 1.3.6.1.2.1.10.5.9.1.11 | Columnx25CallParmInThruPutClasSize | read-write | mandatory | The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone… |
| 1.3.6.1.2.1.10.5.9.1.12 | Columnx25CallParmOutThruPutClasSize | read-write | mandatory | The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tc… |
| 1.3.6.1.2.1.10.5.9.1.13 | Columnx25CallParmCug | read-write | mandatory | The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility request… |
| 1.3.6.1.2.1.10.5.9.1.14 | Columnx25CallParmCugoa | read-write | mandatory | The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three cont… |
| 1.3.6.1.2.1.10.5.9.1.15 | Columnx25CallParmBcug | read-write | mandatory | The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characte… |
| 1.3.6.1.2.1.10.5.9.1.16 | Columnx25CallParmNui | read-write | mandatory | The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero leng… |
| 1.3.6.1.2.1.10.5.9.1.17 | Columnx25CallParmChargingInfo | read-write | mandatory | The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use no… |
| 1.3.6.1.2.1.10.5.9.1.18 | Columnx25CallParmRpoa | read-write | mandatory | The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 char… |
| 1.3.6.1.2.1.10.5.9.1.19 | Columnx25CallParmTrnstDly | read-write | mandatory | The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (t… |
| 1.3.6.1.2.1.10.5.9.1.20 | Columnx25CallParmCallingExt | read-write | mandatory | The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be con… |
| 1.3.6.1.2.1.10.5.9.1.21 | Columnx25CallParmCalledExt | read-write | mandatory | The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be conv… |
| 1.3.6.1.2.1.10.5.9.1.22 | Columnx25CallParmInMinThuPutCls | read-write | mandatory | The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indi… |
| 1.3.6.1.2.1.10.5.9.1.23 | Columnx25CallParmOutMinThuPutCls | read-write | mandatory | The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 ind… |
| 1.3.6.1.2.1.10.5.9.1.24 | Columnx25CallParmEndTrnsDly | read-write | mandatory | The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An… |
| 1.3.6.1.2.1.10.5.9.1.25 | Columnx25CallParmPriority | read-write | mandatory | The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requeste… |
| 1.3.6.1.2.1.10.5.9.1.26 | Columnx25CallParmProtection | read-write | mandatory | A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the p… |
| 1.3.6.1.2.1.10.5.9.1.27 | Columnx25CallParmExptData | read-write | mandatory | The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not ha… |
| 1.3.6.1.2.1.10.5.9.1.28 | Columnx25CallParmUserData | read-write | mandatory | The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call… |
| 1.3.6.1.2.1.10.5.9.1.29 | Columnx25CallParmCallingNetworkFacilities | read-write | mandatory | The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code… |
| 1.3.6.1.2.1.10.5.9.1.30 | Columnx25CallParmCalledNetworkFacilities | read-write | mandatory | The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code.… |
| 1.3.6.1.2.1.10.5.10 | Nodex25ProtocolVersion | |||
| 1.3.6.1.2.1.10.5.10.1 | Nodex25protocolCcittV1976 | |||
| 1.3.6.1.2.1.10.5.10.2 | Nodex25protocolCcittV1980 | |||
| 1.3.6.1.2.1.10.5.10.3 | Nodex25protocolCcittV1984 | |||
| 1.3.6.1.2.1.10.5.10.4 | Nodex25protocolCcittV1988 | |||
| 1.3.6.1.2.1.10.5.10.5 | Nodex25protocolIso8208V1987 | |||
| 1.3.6.1.2.1.10.5.10.6 | Nodex25protocolIso8208V1989 |