MIB Viewer

SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB

34 objects
The MIB module is for representing optical transmitters present in the headend (or indoor) and are supported by a SNMP agent.
OIDNameAccessStatusDescription
1.3.6.1.4.1.5591.1.11.1.1.1IdentityheOpticalTransmitterMIBThe MIB module is for representing optical transmitters present in the headend (or indoor) and are supported by a SNMP agent.
1.3.6.1.4.1.5591.1.11.1.1.1.1NodeheOpTxMIBObjects
1.3.6.1.4.1.5591.1.11.1.1.1.1.1TableheOpTxUnitTablenot-accessiblecurrentA table containing information about headend (or indoor) fiber optic transmitters. These transmitters could be plug-in modules for a chassis, stand-alone pizza…
1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1RowheOpTxUnitEntrynot-accessiblecurrentInformation about each Fiber Optic Transmitter in the subsystem.
1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.1ColumnheOpTxUnitOutputStatusread-onlycurrentThe output status of the transmitter. If all the outputs of the transmitter are off then the variable value shall be off(1), else the value shall be on(2).
1.3.6.1.4.1.5591.1.11.1.1.1.1.1.1.2ColumnheOpTxUnitOnOffControlread-writecurrentThis variable controls the output status of the transmitter. Setting this variable to off(1) will cause all the transmitters outputs to be shut off. Setting th…
1.3.6.1.4.1.5591.1.11.1.1.1.1.2TableheOpTxInputTablenot-accessiblecurrentA table containing information related to RF Parameters in headend (or indoor) fiber optic transmitters. These transmitters could be plug-in modules for a chas…
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1RowheOpTxInputEntrynot-accessiblecurrentInformation about each Fiber Optic Transmitter in the subsystem.
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.1ColumnheOpTxInputIndexnot-accessiblecurrentIndex number corresponding to the RF Input for the transmitter unit.
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.2ColumnheOpTxInputRFPowerread-onlycurrentRF composite input power in 0.1 dBm.
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.3ColumnheOpTxInputModulatorBiasread-onlycurrentModulation Bias.
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.4ColumnheOpTxInputAGCModeread-writecurrentSwitches the transmitter Automatic Gain Control mode of operation either off(1) or on(2).
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.5ColumnheOpTxInputModulationModeread-writecurrentTransmitter modulation mode: cw(1) for Continuous Wave, or modulated(2) for Modulated.
1.3.6.1.4.1.5591.1.11.1.1.1.1.2.1.6ColumnheOpTxInputRFPadLevelread-writecurrentRF Pad Attenuation Level.
1.3.6.1.4.1.5591.1.11.1.1.1.1.3TableheOpTxLaserTablenot-accessiblecurrentA table containing information about transmitter laser(s).
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1RowheOpTxLaserEntrynot-accessiblecurrentA list of information about each laser in the particular transmitter.
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.1ColumnheOpTxLaserIndexnot-accessiblecurrentAn arbitrary value which uniquely identifies the laser.
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.2ColumnheOpTxLaserTempread-onlycurrentTemperature of the Transmitter Laser. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HM…
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.3ColumnheOpTxLaserBiasCurrentread-onlycurrentTransmitter laser bias current. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROP…
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.4ColumnheOpTxLaserOutputPowerread-onlycurrentThe laser output power. This object must provide for the alarm management capabilities with a corresponding entry in the propertyTable of SCTE-HMS-PROPERTY-MIB…
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.5ColumnheOpTxLaserTECCurrentread-onlycurrentLaser Thermo Electric Cooler current.
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.6ColumnheOpTxLaserTyperead-onlycurrentLaser type.
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.7ColumnheOpTxLaserWavelengthread-onlycurrentThe laser wavelength. Typical value might be 155056 (1550.56 nm).
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8ColumnheOpTxLaserOutputStatusread-onlycurrentThe laser output status. The value is on(2), if the Laser output is operating in normal condition The value is off(1), if the laser is either forced to turn of…
1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.9ColumnheOpTxLaserOnOffControlread-writecurrentThis variable controls the output status of the laser. Setting this variable to off(1) will cause the laser output to be shut off. Setting this variable to on(…
1.3.6.1.4.1.5591.1.11.1.1.1.2NodeheOpTxMIBConformance
1.3.6.1.4.1.5591.1.11.1.1.1.2.1NodeheOpTxMIBCompliances
1.3.6.1.4.1.5591.1.11.1.1.1.2.1.1ComplianceheOpTxCompliancecurrentThe minimum compliance statement for indoor optical transmitters.
1.3.6.1.4.1.5591.1.11.1.1.1.2.2NodeheOpTxMIBGroups
1.3.6.1.4.1.5591.1.11.1.1.1.2.2.1GroupheOpTxUnitMandatoryGroupcurrentThe main group defines objects which are common to all indoor optical transmitter modules.
1.3.6.1.4.1.5591.1.11.1.1.1.2.2.2GroupheOpTxLaserMandatoryGroupcurrentThe laser group defines laser objects which are common to all indoor optical transmitter modules.
1.3.6.1.4.1.5591.1.11.1.1.1.2.2.3GroupheOpTxUnitTableGroupcurrentThe unit group defines objects which are defined in the SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB MIB module.
1.3.6.1.4.1.5591.1.11.1.1.1.2.2.4GroupheOpTxInputTableGroupcurrentThe input group defines RF objects which are defined in the SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB MIB module.
1.3.6.1.4.1.5591.1.11.1.1.1.2.2.5GroupheOpTxLaserTableGroupcurrentThe laser group defines laser objects which are defined in the SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB MIB module.