MIB Viewer

SL-CHASSIS-MIB

27 objects
This MIB module describes the Multi-Chassis information
OIDNameAccessStatusDescription
1.3.6.1.4.1.4515.1.3.18IdentityslChassisThis MIB module describes the Multi-Chassis information
1.3.6.1.4.1.4515.1.3.18.1NodeslChassisInfo
1.3.6.1.4.1.4515.1.3.18.1.1ScalarslChassisInfoNodeSlotIdread-writecurrentThe slot ID of the node. This number is assigned to the node before it is a part of the chassis. Slot ID should be assigned also to the GNE nodes. The Slot ID …
1.3.6.1.4.1.4515.1.3.18.1.2ScalarslChassisInfoNodeRoleread-writecurrentThe role of the node. gneNode - for Master or Backup chassis GNE node. internalSlotNode - for non gne node. none - the node is in a simple chassis
1.3.6.1.4.1.4515.1.3.18.1.3ScalarslChassisInfoLanVrrpIpread-writecurrentThe VRRP ip of the node on the LAN interface.
1.3.6.1.4.1.4515.1.3.18.1.4ScalarslChassisInfoOscVrrpIpread-writecurrentThe VRRP ip of the node on the OSC interface.
1.3.6.1.4.1.4515.1.3.18.1.5ScalarslChassisInfoTopologyread-writecurrentThe topology mode of the multichassis: osc - the management use the LAN IP of the GNE and VRRP. lan - the management use the OSC IP of the GNE and VRRP. simple…
1.3.6.1.4.1.4515.1.3.18.1.6ScalarslChassisInfoVrrpEnableread-writecurrentEnable/Disable the activation of the VRRP protocol by the GNE
1.3.6.1.4.1.4515.1.3.18.2NodeslChassisSlot
1.3.6.1.4.1.4515.1.3.18.2.1TableslChassisSlotTablenot-accessiblecurrentThis table contains the chassis slots.
1.3.6.1.4.1.4515.1.3.18.2.1.1RowslChassisSlotEntrynot-accessiblecurrentAn entry in the Chassis Slot table.
1.3.6.1.4.1.4515.1.3.18.2.1.1.1ColumnslChassisSlotIdread-onlycurrentThe slot ID of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.2ColumnslChassisSlotRoleread-onlycurrentThe role of the node. gneNode - for Master or Backup chassis GNE node. internalNode - for non gne node
1.3.6.1.4.1.4515.1.3.18.2.1.1.3ColumnslChassisSlotInternalIpread-onlycurrentThe internal ip of the node. This address is used to identify the node and not for management access.
1.3.6.1.4.1.4515.1.3.18.2.1.1.4ColumnslChassisSlotProductTyperead-onlycurrentThe sysObjectID of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.5ColumnslChassisSlotSysNameread-onlycurrentThe SysName of the node
1.3.6.1.4.1.4515.1.3.18.2.1.1.6ColumnslChassisSlotSnmp161Portread-onlycurrentThe SNMP Gte/Set port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.7ColumnslChassisSlotSnmp162MinPortread-onlycurrentThe minimal SNMP Trap port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.8ColumnslChassisSlotSnmp162MaxPortread-onlycurrentThe maximal SNMP Trap port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.9ColumnslChassisSlotHttpPortread-onlycurrentThe HTTP port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.10ColumnslChassisSlotTelnetPortread-onlycurrentThe Telnet port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.12ColumnslChassisSlotFtpPortread-onlycurrentThe Ftp port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.13ColumnslChassisSlotTL1Portread-onlycurrentThe TL1 port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.14ColumnslChassisSlotPingIdentifierread-onlycurrentThe ping identifier of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.15ColumnslChassisSlotHttpsPortread-onlycurrentThe HTTPS port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.16ColumnslChassisSlotSshPortread-onlycurrentThe SSH port of the node.
1.3.6.1.4.1.4515.1.3.18.2.1.1.17ColumnslChassisSlotSTL1Portread-onlycurrentThe TL1 over SSH port of the node.