SL-SFP-MIB
169 objects
This MIB module describes the SFP Modules
Imported Objects
| FLOAT-TC-MIB MISSING | Float128TC Float32TC Float64TC |
| IF-MIB | InterfaceIndex |
| PerfHist-TC-MIB | PerfCurrentCount PerfIntervalCount PerfTotalCount |
| SL-ENTITY-MIB | CleiCode |
| SL-NE-MIB | sitelight |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks |
| SNMPv2-TC | DisplayString TimeStamp TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4515.1.10 | IdentityslSfp | This MIB module describes the SFP Modules | ||
| 1.3.6.1.4.1.4515.1.10.1 | NodesfpConf | |||
| 1.3.6.1.4.1.4515.1.10.1.1 | TablesfpConfigTable | not-accessible | current | The SFP configuration table. The table defines the configuration of the SFP-1310 and the SFP-WDM modules. |
| 1.3.6.1.4.1.4515.1.10.1.1.1 | RowsfpConfigEntry | not-accessible | current | An entry in the SFP configuration table. The index to this table is the same as the ifIndex of the SFP. The SFP Config Table contain and entry for each module … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.1 | ColumnsfpConfigInterface | read-only | current | The Interface Index of the SFP (type=196). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.2 | ColumnsfpConfigXcvrId | read-only | current | The identifier value specifies the physical device described by the serial information. This value shall be included in the serial data. The defined identifier… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.3 | ColumnsfpConfig1310ExtXcvrId | read-only | current | The extended identifier value provides additional information about the 1310 transceiver. The defined identifier values are: 00h GBIC definition is not specifi… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.4 | ColumnsfpConfigWdmExtXcvrId | read-only | current | This field is used to distinguish between different types of DWDM transceivers and different power and environmental classes. The defined identifier values are… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.5 | ColumnsfpConfigConnectorCode | read-only | current | The identifier value specifies the physical device described by the serial information. This value shall be included in the serial data. The defined identifier… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.6 | ColumnsfpConfigInfibandCompliance | read-only | current | The following bit significant indicators define the Infiband interfaces that are supported by the transceiver. The defined identifier values are: Bits 0: 1X SX… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.7 | ColumnsfpConfigEsconCompliance | read-only | current | The following bit significant indicators define the ESCON interfaces that are supported by the transceiver. The defined identifier values are: Bits 0: ESCON MM… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.8 | ColumnsfpConfigSonetCompliance | read-only | current | The following bit significant indicators define the SONET interfaces that are supported by the transceiver. The defined identifier values are: Bits 0: SONET re… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.9 | ColumnsfpConfigGbeCompliance | read-only | current | The following bit significant indicators define the Infiband interfaces that are supported by the transceiver. The defined identifier values are: Bits 0: 1000B… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.10 | ColumnsfpConfigFcCompliance | read-only | current | The following bit significant indicators define the FC interfaces that are supported by the transceiver. The defined identifier values are: - Fibre Channel lin… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.11 | ColumnsfpConfigEncodingCode | read-only | current | The encoding value indicates the serial encoding mechanism that is the nominal design target of the particular transceiver. The value shall be contained in the… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.12 | ColumnsfpConfigNominalBitRate | read-only | current | The nominal bit rate (BR, nominal) is specified in units of 100 Megabits per second, rounded off to the nearest 100 Megabits per second. The bit rate includes … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.13 | ColumnsfpConfigLength9mKm | read-only | current | Addition to EEPROM data from original GBIC definition. This value specifies the link length that is supported by the transceiver while operating in compliance … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.14 | ColumnsfpConfigLength9m100m | read-only | current | This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using single mode fiber. … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.15 | ColumnsfpConfigLength50m10m | read-only | current | This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 50 micron multi-mod… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.16 | ColumnsfpConfigLength62m10m | read-only | current | This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using 62.5 micron multi-m… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.17 | ColumnsfpConfigLengthCopper1m | read-only | current | This value specifies the link length that is supported by the transceiver while operating in compliance with the applicable standards using copper cable. The v… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.18 | ColumnsfpConfigMaxTemp | read-only | current | This field defines the maximum operating case temperature the module is rated for. The maximum case temperature is encoded as a signed two�s complement value… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.19 | ColumnsfpConfigMinTemp | read-only | current | This field defines the minimum operating case temperature the module is rated for. The maximum case temperature is encoded as a signed two�s complement value… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.20 | ColumnsfpConfigMaxSupplyCurrent | read-only | current | This field defines the maximum supply current the module will consume under worst case conditions. The maximum current is the byte value * 4mA. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.21 | ColumnsfpConfigChannelSpacing | read-only | current | In the case of SFP: This bit field value identifies the densest channel spacing the module is compatible with and the number of channels over which the module … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.22 | ColumnsfpConfigVendorName | read-only | current | The vendor name is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h). The vendor name shall be … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.23 | ColumnsfpConfigOptionalWdm | read-only | current | The bits in the option field shall specify the options implemented in the transceiver. The following bits are defined: Bits 7: Optional Interrupt Pin Functiona… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.24 | ColumnsfpConfigVendorOUI | read-only | current | The vendor organizationally unique identifier field (vendor OUI) is a 3-byte field that contains the IEEE Company Identifier for the vendor. A value of all zer… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.25 | ColumnsfpConfigVendorPN | read-only | current | The vendor part number (vendor PN) is a 16-byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defining th… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.26 | ColumnsfpConfigVendorRev | read-only | current | The vendor revision number (vendor rev) is a 4-byte field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), definin… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.27 | ColumnsfpConfigWaveLength | read-only | current | In the case of DWDM: Nominal transmitter output wavelength in units of 0.01nm. As an example, a wavelength of 1550.51nm would be encoded as: 155051. In the cas… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.28 | ColumnsfpConfigExtendedOptions | read-only | current | Specify the bitmap options implemented in the transceiver as described in. The bits definition is: 5 RATE_SELECT is implemented NOTE: Lack of implemention does… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.29 | ColumnsfpConfigMaxBitRate | read-only | current | The upper bit rate limit at which the transceiver will still meet its specifications (BR, max) is specified in units of 1% above the nominal bit rate. A value … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.30 | ColumnsfpConfigMinBitRate | read-only | current | The lower bit rate limit at which the transceiver will still meet its specifications (BR, min) is specified in units of 1% below the nominal bit rate. A value … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.31 | ColumnsfpConfigVendorSN | read-only | current | The vendor serial number (vendor SN) is a 16 character field that contains ASCII characters, left-aligned and padded on the right with ASCII spaces (20h), defi… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.32 | ColumnsfpConfigDateCode | read-only | current | The date code is an 6-byte field that contains the vendor�s date code in ASCII characters. The date code is mandatory. The date code shall be in the format: … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.33 | ColumnsfpConfigDiagnosticMonitoring | read-only | current | A field with 8 single bit indicators which describe the optional digital diagnostic features implemented in the transceiver. Since transceivers will not necess… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.34 | ColumnsfpConfigEnhanceOptions | read-only | current | A field with 6 single bit indicators which describe the optional digital diagnostic features implemented in the transceiver. Since transceivers will not necess… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.35 | ColumnsfpConfig8472Compliance | read-only | current | An unsigned integer that indicates which feature set(s) are implemented in the transceiver. The defined values are: 0 - Digital diagnostic functionality not in… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.36 | ColumnsfpConfigTunableWaveLength | read-write | current | Wavelength Tuning Control. The availability of this function is indicated in the object sfpConfigChannelSpacing, where number of channels greater than 1 indica… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.37 | ColumnsfpConfigVoaControl | read-write | current | Variable Optical Attenuator Control. Used to control the wavelength in tunable modules. The availability of this function is indicated in Bit 3 of sfpConfigOpt… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.38 | ColumnsfpConfigVdtControl | read-write | current | Variable Decision Threshold Control. Used to control the variable decision threshold function. The availability of this function is indicated in Bit 0 of sfpCo… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.39 | ColumnsfpConfigPilotToneModulation | read-write | current | Pilot Tone Injection Modulation Depth. When basic MSA pilot tone injection functionality is implemented (as indicated in the Serial ID fields by bits 4-6 of of… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.40 | ColumnsfpConfigCleiCode | read-only | current | The COMMON LANGUAGE Equipment Code. The CLEI code contains an intelligent ten-character code that identifies the telecommunications equipment. The Clei Code re… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.41 | ColumnsfpConfigXfpExtXcvrId | read-only | current | This field is used to distinguish between different types of DWDM transceivers and different power and environmental classes. The defined identifier values are… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.42 | ColumnsfpConfigXfpEncodingCode | read-only | current | The encoding value indicates the serial encoding mechanism that is the nominal design target of the particular transceiver. The value shall be contained in the… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.43 | ColumnsfpConfigXfpMinBitRate | read-only | current | The minimum bit rate (BR, minimum) is specified in units of 100 Megabits per second, rounded off to the nearest 100 Megabits per second. The bit rate includes … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.44 | ColumnsfpConfigXfpMaxBitRate | read-only | current | The maximum bit rate (BR, maximum) is specified in units of 100 Megabits per second, rounded off to the nearest 100 Megabits per second. The bit rate includes … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.45 | ColumnsfpConfig10GSonetCompliance | read-only | current | The following bit significant indicators define the SONET interfaces that are supported by the transceiver. The defined identifier values are: Bits 0-1: Reserv… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.46 | ColumnsfpConfig10GbeCompliance | read-only | current | The following bit significant indicators define the 10GbE interfaces that are supported by the transceiver. The defined identifier values are: Bits 0: Reserved… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.47 | ColumnsfpConfig10GFcCompliance | read-only | current | The following bit significant indicators define the 10GFC interfaces that are supported by the transceiver. The defined identifier values are: - Fibre Channel … |
| 1.3.6.1.4.1.4515.1.10.1.1.1.48 | ColumnsfpConfigXfpDeviceTech | read-only | current | The following bit significant indicators define the XFP device technology: Bits 0: 0-Transmitter not Tunable 1-Transmitter Tunable Bits 1: Detector Type: 0-PIN… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.49 | ColumnsfpConfigXfpTuningSupported | read-only | current | Indicate the XFP tuning support: Bit1: wavelenght (Tunable DWDM - selection in 50 pm steps) Bit2: frequency (Tunable DWDM - selection by channel number) For ex… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.50 | ColumnsfpConfigXfpDesiredChannel | read-write | current | User input of channel number, which is an integer 1 to N (N=Number of Channels). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.51 | ColumnsfpConfigXfpDesiredWl | read-write | current | User input of Wavelength setpoint (in units of 50 picometers). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.52 | ColumnsfpConfigXfpWlError | read-only | current | Monitor of Current Wavelength Error(in units of 5 picometers). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.53 | ColumnsfpConfigXfpDesiredFreq | read-write | current | User input of channel number, which is an integer to N (N=Number of Channels). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.54 | ColumnsfpConfigXfpFreqError | read-only | current | Frequency error reported in 16 bit signed integer with LSB=0.1 GHz. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.55 | ColumnsfpConfigXfpDitherSupported | read-only | current | Tx Dither Supported. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.56 | ColumnsfpConfigXfpDitherAdmin | read-write | current | Enable/Disable the dithering function. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.57 | ColumnsfpConfigXfpCapFreqFirstThz | read-only | current | Lasers First Frequency (THz) capability. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.58 | ColumnsfpConfigXfpCapFreqFirst10Ghz | read-only | current | Lasers First Frequency (GHz*10) capability. This value should be added to sfpConfigXfpCapFreqFirstThz. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.59 | ColumnsfpConfigXfpCapFreqLastThz | read-only | current | Lasers Last Frequency (THz) capability. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.60 | ColumnsfpConfigXfpCapFreqLast10Ghz | read-only | current | Lasers Last Frequency (GHz*10) capability. This value should be added to sfpConfigXfpCapFreqLastThz. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.61 | ColumnsfpConfigXfpCapMaxSpacing10Ghz | read-only | current | Lasers maximum supported grid spacing (GHz*10) capability. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.62 | ColumnsfpConfigXfpCalibrationSupported | read-only | current | Calibarion Supported. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.63 | ColumnsfpConfigXfpCalibrationEnabled | read-write | current | Enable/Disable the calibration process. Changing the value to Enable when a signal exist invokes an immidiate calibration process. Changing the value to Disabl… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.70 | ColumnsfpConfigCfpExtId | read-only | current | Extended Identifier bit fields: Bits 7-6 - Power Class: 00b: Power Class 1 Module (? 8 W max), 01b: Power Class 2 Module (?16 W max), 10b: Power Class 3 Module… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.71 | ColumnsfpConfigCfpConnectorType | read-only | current | Connector Type Code: 00h: Undefined, 01h : SC, 07h : LC, 08h : MT-RJ, 09h : MPO, Other Codes : Reserved |
| 1.3.6.1.4.1.4515.1.10.1.1.1.72 | ColumnsfpConfigCfpEthernetCode | read-only | current | Ethernet Application Code. 00h: Undefined type, 01h: 100GE SMF 10km, 100GE-LR4, 02h: 100GE SMF 40km, 100GE-ER4, 03h: 100GE MMF 100m OM3, 100GE-SR10, 04h: For f… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.73 | ColumnsfpConfigCfpFcCode | read-only | current | Fiber Channel Application Code: Undefined |
| 1.3.6.1.4.1.4515.1.10.1.1.1.74 | ColumnsfpConfigCfpCopperCode | read-only | current | Copper Link Application Code: Undefined |
| 1.3.6.1.4.1.4515.1.10.1.1.1.75 | ColumnsfpConfigCfpSonetCode | read-only | current | SONET/SDH Application Code: 00h: Undefined type, 01h: VSR2000-3R2, 02h: VSR2000-3R3, 03h: VSR2000-3R5, 04h ~ 0FFh: Reserved |
| 1.3.6.1.4.1.4515.1.10.1.1.1.76 | ColumnsfpConfigCfpOtnCode | read-only | current | OTN Application Code: 0h: Undefined type, 01h: VSR2000-3R2F, 02h: VSR2000-3R3F, 03h: VSR2000-3R5F, 04h: VSR2000-3L2F, 05h: VSR2000-3L3F, 06h: VSR2000-3L5F, 07h… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.77 | ColumnsfpConfigCfpSupportedRates | read-only | current | Additional Capable Rates Supported Bitmap: Bits 7-5 - Reserved Bit 4 - 111.8 Gbps Bit 3 - 103.125 Gbps Bit 2 - 41.25 Gbps Bit 1 - 43 Gbps Bit 0 - 39.8 Gbps |
| 1.3.6.1.4.1.4515.1.10.1.1.1.78 | ColumnsfpConfigCfpSupportedLanes | read-only | current | Number of Lanes Supported: Bits 7-4 - Number of Network Lanes The value of 0 represents 16 network lanes supported. The values of 1 through 15 represent the ac… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.79 | ColumnsfpConfigCfpMediaProperties | read-only | current | Media Properties bit fields: Bits 7 - 6 Media Type: 00b: SMF , 01b: MMF (OM3), 10b: Reserved, 11b: Copper Bit 5 - Directionality: 0: Normal, 1: BiDi Bit 4 Opti… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.80 | ColumnsfpConfigCfpMaxNetworkLaneRate | read-only | current | Maximum Network Lane Bit Rate: 8-bit value x 0.2 Gbps |
| 1.3.6.1.4.1.4515.1.10.1.1.1.81 | ColumnsfpConfigCfpMaxHostLaneRate | read-only | current | Maximum Host Lane Bit Rate: 8-bit value x 0.2 Gbps |
| 1.3.6.1.4.1.4515.1.10.1.1.1.82 | ColumnsfpConfigCfpMaxSmFiberLength | read-only | current | Maximum Single Mode Optical Fiber Length: 8-bit value x 1 km for single mode fiber length |
| 1.3.6.1.4.1.4515.1.10.1.1.1.83 | ColumnsfpConfigCfpMaxMmFiberLength | read-only | current | Maximum Multi-Mode Optical Fiber Length: 8-bit value x 10 m for multi-mode fiber length |
| 1.3.6.1.4.1.4515.1.10.1.1.1.84 | ColumnsfpConfigCfpMaxCopperCableLength | read-only | current | Maximum Copper Cable Length: 8-bit value x 1 m for copper cable length |
| 1.3.6.1.4.1.4515.1.10.1.1.1.85 | ColumnsfpConfigCfpMinWavelenPerActive | read-only | current | Minimum Wavelength per Active Fiber: 16-bit unsigned value x 0.025 nm. (MSB is at 8012h, LSB is at 8013h) |
| 1.3.6.1.4.1.4515.1.10.1.1.1.86 | ColumnsfpConfigCfpMaxWavelenPerActive | read-only | current | Maximum Wavelength per Active Fiber: 16-bit unsigned value x 0.025 nm. (MSB is at 8014h, LSB is at 8015h) |
| 1.3.6.1.4.1.4515.1.10.1.1.1.87 | ColumnsfpConfigCfpMaxLenOpticalWidth | read-only | current | Maximum per Lane Optical Width: Guaranteed range of laser wavelength. 16-bit unsigned value x 1 pm. (MSB is at 8016h, LSB is at 8017h) |
| 1.3.6.1.4.1.4515.1.10.1.1.1.88 | ColumnsfpConfigCfpSpacing | read-write | current | The spacing between two lanes: 0- unknown spacing 1 - 100GHz spacing 2 - 50GHz spacing 3 - 25GHz spacing 4 - 12.5GHz spacing 5 - 6.25GHz spacing (flex grid) |
| 1.3.6.1.4.1.4515.1.10.1.1.1.100 | ColumnsfpConfigQsfppEthernetCode | read-only | current | Maximum per Lane Optical Width: Guaranteed range of laser wavelength. 16-bit unsigned value x 1 pm. (MSB is at 8016h, LSB is at 8017h) |
| 1.3.6.1.4.1.4515.1.10.1.1.1.101 | ColumnsfpConfigQsfppSonetCode | read-write | current | The spacing between two lanes: 0- unknown spacing 1 - 100G spacing 2 - 50G spacing 3- 25G spacing |
| 1.3.6.1.4.1.4515.1.10.1.1.1.110 | ColumnsfpConfigCxpExtId | read-write | current | Extended Identifier (Byte 129): Bits 7-5 - Power Class: 000: 0.25W max - Class 0 001: 1.0W max - Class 1 010: 1.5W max - Class 2 011: 2.5W max - Class 3 100: 4… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.111 | ColumnsfpConfigCxpConnectorType | read-write | current | Connector Type Code (Byte 130): 30h: Passive Copper Cable Assembly 31h: Active Copper Cable Assembly (ref. Byte 147) 32h: Active Optical Cable Assembly 33h: Op… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.112 | ColumnsfpConfigCxpMaxSupportedRate | read-write | current | Max per-channel bit rate (Byte 134): Max signal rate = binary value x 100 Mb/s |
| 1.3.6.1.4.1.4515.1.10.1.1.1.113 | ColumnsfpConfigCxpNominalWavelength | read-write | current | Wavelength/Attenuation (Bytes 135-136): Optical: Nominal Laser Wavelength Wavelength in nm = value / 20): e.g. 42h 04h = 16,900, 16,900/20 = 845 nm Copper: Nom… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.114 | ColumnsfpConfigCxpDeviceTech | read-write | current | Device Technology (Byte 147): Bits 7-4 (Device Technology): 0000: 850 nm VCSEL 0001:1310 nm VCSEL 0010:1550 nm VCSEL 0011: 1310 nm FP 0100:1310 nm DFB 0101:155… |
| 1.3.6.1.4.1.4515.1.10.1.1.1.115 | ColumnsfpConfigCohRxDesiredChannel | read-write | current | User input of RX channel number, which is an integer 1 to N (N=Number of Channels). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.116 | ColumnsfpConfigCohRxDesiredWl | read-write | current | User input of RX Wavelength setpoint (in units of 50 picometers). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.117 | ColumnsfpConfigCohRxDesiredFreq | read-write | current | User input of channel number, which is an integer to N (N=Number of Channels). |
| 1.3.6.1.4.1.4515.1.10.1.1.1.118 | ColumnsfpConfigCohCurrentCD | read-only | current | Current Chromatic Dispersion counter. Units are in ps/nm |
| 1.3.6.1.4.1.4515.1.10.1.1.1.119 | ColumnsfpConfigCohCurrentOSNR | read-only | current | Current SNR. Units are in 0.1dB |
| 1.3.6.1.4.1.4515.1.10.1.1.1.120 | ColumnsfpConfigCohAverageOSNR | read-only | current | Average SNR over PM interval. Units are in 0.1dB |
| 1.3.6.1.4.1.4515.1.10.1.1.1.121 | ColumnsfpConfigCohMaxCD | read-only | current | Maximal Chromatic Dispersion counter. Units are in ps/nm |
| 1.3.6.1.4.1.4515.1.10.1.1.1.122 | ColumnsfpConfigNyquist | read-write | current | Nyquist - True (ON) or False (OFF). Default is OFF |
| 1.3.6.1.4.1.4515.1.10.1.1.1.123 | ColumnsfpConfigModulationFormat | read-write | current | The DCFP2 modulation format: 0 - N/A 1 - 200G 16QAM (default for 200G) 2 - 200G 8QAM 3 - 100G QPSK 4 - 400G ZR 5 - 400G OpenROADM 6 - 400G ZR+ 7 - FlexO |
| 1.3.6.1.4.1.4515.1.10.1.1.1.124 | ColumnsfpConfigEnhancedNetPerfMode | read-write | current | 0 - N/A 1 - Enable 2 - Disable Enable/Disable enhanced network preformance mode. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.125 | ColumnsfpConfigDspType | read-only | current | 0 - N/A 1 - M30 2 - M35 3 - E20 4 - E30 |
| 1.3.6.1.4.1.4515.1.10.1.1.1.126 | ColumnsfpConfigRxVoaMode | read-write | current | 0 - N/A 1 - Enable 2 - Disable Enable/Disable the Rx VOA. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.127 | ColumnsfpConfigRxVoaControl | read-write | current | The target RX power on 0.01dBm units. |
| 1.3.6.1.4.1.4515.1.10.1.1.1.128 | ColumnsfpConfigModuleType | read-write | current | 0 - undefined 1 - CFP2-DCO (default) 2 - QSFPDD-DCO |
| 1.3.6.1.4.1.4515.1.10.2 | NodesfpDiag | |||
| 1.3.6.1.4.1.4515.1.10.2.1 | TablesfpDiagTable | not-accessible | current | The SFP diagnostic table. The table defines the status and control of the alarms and warnings of the SFP-1310 and the DWDM SFP-15xy modules. |
| 1.3.6.1.4.1.4515.1.10.2.1.1 | RowsfpDiagEntry | not-accessible | current | An entry in the SFP diagnostic table. The index to this table is the same as the ifIndex of the SFP. The SFP Diagnostic Table contain and entry for each SFP mo… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.1 | ColumnsfpDiagInterface | read-only | current | The Interface Index of the SFP (type=196). |
| 1.3.6.1.4.1.4515.1.10.2.1.1.2 | ColumnsfpDiagHighTempAlmThreshold | read-write | current | The threshold value for high temperature alarm. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of -1… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.3 | ColumnsfpDiagLowTempAlmThreshold | read-write | current | The threshold value for low temperature alarm. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of -12… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.4 | ColumnsfpDiagHighTempWrnThreshold | read-write | current | The threshold value for high temperature warning. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of … |
| 1.3.6.1.4.1.4515.1.10.2.1.1.5 | ColumnsfpDiagLowTempWrnThreshold | read-write | current | The threshold value for low temperature warning. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of -… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.6 | ColumnsfpDiagHighVoltAlmThreshold | read-write | current | The threshold value for high voltage alarm. The value 0 means 0 Volts. An increment on one is equivalent to 100 uVolt, yielding a total range of +6.55 Volts. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.7 | ColumnsfpDiagLowVoltAlmThreshold | read-write | current | The threshold value for low voltage alarm. The value 0 means 0 Volts. An increment on one is equivalent to 100 uVolt, yielding a total range of +6.55 Volts. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.8 | ColumnsfpDiagHighVoltWrnThreshold | read-write | current | The threshold value for high voltage warning. The value 0 means 0 Volts. An increment on one is equivalent to 100 uVolt, yielding a total range of +6.55 Volts. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.9 | ColumnsfpDiagLowVoltWrnThreshold | read-write | current | The threshold value for low voltage warning. The value 0 means 0 Volts. An increment on one is equivalent to 100 uVolt, yielding a total range of +6.55 Volts. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.10 | ColumnsfpDiagHighTxBiasAlmThreshold | read-write | current | The threshold value for high voltage alarm. The value 0 means 0 Volt. An increment on one is equivalent to 2 uA, yielding a total range of 0 to 131 mA. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.11 | ColumnsfpDiagLowTxBiasAlmThreshold | read-write | current | The threshold value for low voltage alarm. The value 0 means 0 Volts. An increment on one is equivalent to 2 uA, yielding a total range of 0 to 131 mA. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.12 | ColumnsfpDiagHighTxBiasWrnThreshold | read-write | current | The threshold value for high voltage warning. The value 0 means 0 Volt. An increment on one is equivalent to 2 uA, yielding a total range of 0 to 131 mA. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.13 | ColumnsfpDiagLowTxBiasWrnThreshold | read-write | current | The threshold value for low voltage warning. The value 0 means 0 Volts. An increment on one is equivalent to 2 uA, yielding a total range of 0 to 131 mA. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.14 | ColumnsfpDiagHighTxPowerAlmThreshold | read-write | current | The threshold value for high TX power alarm. The value 0 means 0 Volt. An increment on one is equivalent to 1 uW, yielding a total range of 0 to 65.535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.15 | ColumnsfpDiagLowTxPowerAlmThreshold | read-write | current | The threshold value for low TX power alarm. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 65.535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.16 | ColumnsfpDiagHighTxPowerWrnThreshold | read-write | current | The threshold value for high TX power warning. The value 0 means 0 Volt. An increment on one is equivalent to 1 uW, yielding a total range of 0 to 65.535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.17 | ColumnsfpDiagLowTxPowerWrnThreshold | read-write | current | The threshold value for low TX power warning. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 65.535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.18 | ColumnsfpDiagHighRxPowerAlmThreshold | read-write | current | The threshold value for high RX power alarm. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.19 | ColumnsfpDiagLowRxPowerAlmThreshold | read-write | current | The threshold value for low RX power alarm. The value 0 means 0 Volt. An increment on one is equivalent to 1 uW, yielding a total range of 0 to 6.5535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.20 | ColumnsfpDiagHighRxPowerWrnThreshold | read-write | current | The threshold value for high RX power warning. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.21 | ColumnsfpDiagLowRxPowerWrnThreshold | read-write | current | The threshold value for low RX power warning. The value 0 means 0 Volt. An increment on one is equivalent to 1 uW, yielding a total range of 0 to 6.5535 mW. |
| 1.3.6.1.4.1.4515.1.10.2.1.1.22 | ColumnsfpDiagHighLaserTempAlmThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.23 | ColumnsfpDiagLowLaserTempAlmThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.24 | ColumnsfpDiagHighLaserTempWrnThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.25 | ColumnsfpDiagLowLaserTempWrnThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.26 | ColumnsfpDiagHighWaveLenAlmThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.27 | ColumnsfpDiagLowWaveLenAlmThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.28 | ColumnsfpDiagHighWaveLenWrnThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.29 | ColumnsfpDiagLowWaveLenWrnThreshold | read-write | current | For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting defined by bit 1 of the object… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.30 | ColumnsfpDiagHighTecCurrAlmThreshold | read-write | current | The threshold value for high TEC current alarm. The reported TEC current is defined as a positive number for cooling and a negative number for heating starting… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.31 | ColumnsfpDiagLowTecCurrAlmThreshold | read-write | current | The threshold value for low TEC current alarm. The reported TEC current is defined as a positive number for cooling and a negative number for heating starting … |
| 1.3.6.1.4.1.4515.1.10.2.1.1.32 | ColumnsfpDiagHighTecCurrWrnThreshold | read-write | current | The threshold value for high TEC current warning. The reported TEC current is defined as a positive number for cooling and a negative number for heating starti… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.33 | ColumnsfpDiagLowTecCurrWrnThreshold | read-write | current | The threshold value for low TEC current warning. The reported TEC current is defined as a positive number for cooling and a negative number for heating startin… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.34 | ColumnsfpDiagModuleTemperature | read-only | current | Internally measured module temperature. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of -128 to +1… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.35 | ColumnsfpDiagSupplyVoltage | read-only | current | Internally measured supply voltage in transceiver. The value 0 means 0 Volts. An increment on one is equivalent to 100 uVolt, yielding a total range of +6.55 V… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.36 | ColumnsfpDiagTxBias | read-only | current | Internally measured TX Bias Current. The value 0 means 0 Volt. An increment on one is equivalent to 2 uA, yielding a total range of 0 to 131 mA. Accuracy is ve… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.37 | ColumnsfpDiagTxOutputPower | read-only | current | Measured TX output power. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. For the vendor spec… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.38 | ColumnsfpDiagRxInputPower | read-only | current | Measured RX input power. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.5535 mW. For the vendor speci… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.39 | ColumnsfpDiagRxLaserTemperature | read-only | current | Measured Laser Temperature. For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting de… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.40 | ColumnsfpDiagRxMeasuredWavelength | read-only | current | Measured Laser Wavelength. For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�s reporting def… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.41 | ColumnsfpDiagRxTecCurrent | read-only | current | Measured Laser Temperature or Wavelength. For DWDM applications, the diagnostic interface report either laser wavelength or temperature, with a given module�… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.42 | ColumnsfpDiagAlarms | read-only | current | This object indicates the Alarms of the SFP module. The sfpDiagAlarms is a bit map represented as a sum, therefore, it can represent multiple failures (alarms)… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.43 | ColumnsfpDiagAlarmsMask | read-write | current | This object indicates the Masking of the Alarms of the SFP module. The sfpDiagAlarmsMask is a bit map. Any of the alarm and warning flags can be masked by writ… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.44 | ColumnsfpDiagWarnings | read-only | current | This object indicates the Warnings of the SFP module. The sfpDiagWarnings is a bit map represented as a sum, therefore, it can represent multiple failures (ala… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.45 | ColumnsfpDiagWarningsMask | read-write | current | This object indicates the Masking of the Warnings of the SFP module. The sfpDiagWarningsMask is a bit map. Any of the alarm and warning flags can be masked by … |
| 1.3.6.1.4.1.4515.1.10.2.1.1.46 | ColumnsfpDiagConfLowRxPowerAlmThreshold | read-write | current | Configured threshold value for low RX power alarm. Changing this value doen't affect the SFP and is implemented by software. The threshold level specified in 0… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.47 | ColumnsfpDiagRxInputPowerFloat | read-only | current | Measured RX input power sepcified in floating units. This object is used for power < -40dBm that can be achieved with SFP external calibration. When not used t… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.48 | ColumnsfpDiagChannelRxInputPower | read-only | current | Measured RX input power of the provisioned cahnnel. The value 0 means 0 Watts. An increment on one is equivalent to 0.1 uW, yielding a total range of 0 to 6.55… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.50 | ColumnsfpDiagCxpTxTemp | read-only | current | Internally measured Tx temperature. The value 0 means -128 Celsius. An increment on one is equivalent to 1/256 degree, yielding a total range of -128 to +128 C… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.51 | ColumnsfpDiagCxpHighTxTempAlmThreshold | read-only | current | The threshold value for high Tx temperature alarm. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.52 | ColumnsfpDiagCxpLowTxTempAlmThreshold | read-only | current | The threshold value for low Tx temperature alarm. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of … |
| 1.3.6.1.4.1.4515.1.10.2.1.1.53 | ColumnsfpDiagCxpRxTemp | read-only | current | Internally measured Rx temperature. The value 0 means -128 Celsius. An increment on one is equivalent to 1/256 degree, yielding a total range of -128 to +128 C… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.54 | ColumnsfpDiagCxpHighRxTempAlmThreshold | read-only | current | The threshold value for high Rx temperature alarm. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of… |
| 1.3.6.1.4.1.4515.1.10.2.1.1.55 | ColumnsfpDiagCxpLowRxTempAlmThreshold | read-only | current | The threshold value for low Rx temperature alarm. The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree, yielding a total range of … |
| 1.3.6.1.4.1.4515.1.10.2.1.1.56 | ColumnsfpDiagOtdrFiberCutRange | read-only | current | The OTDR calculated range to the fiber cut |
| 1.3.6.1.4.1.4515.1.10.2.1.1.57 | ColumnsfpDiagModuleTemperatureCelsius | read-only | current | Internally measured module temperature, while degress in Celsuis. Total range of -128 to +128 Celsius. Temperature accuracy is vendor specific but must be bett… |
| 1.3.6.1.4.1.4515.1.10.3 | NodesfpTraps | |||
| 1.3.6.1.4.1.4515.1.10.3.1 | NotificationsfpConfigChangeTrap | current | A sfpTrapsChangeTrap trap is sent when the content of an instance sfpConfigEntry changes. It can be utilized by an NMS to trigger polls. | |
| 1.3.6.1.4.1.4515.1.10.4 | NodesfpTune |