This MIB module describes the available on-demand tests.
OIDNameAccessStatusDescription
1.3.6.1.4.1.4515.1.3.13IdentityslTestsThis MIB module describes the available on-demand tests.
1.3.6.1.4.1.4515.1.3.13.1NodeslTestsIfLoop
1.3.6.1.4.1.4515.1.3.13.1.1TableslTestsIfLoopTablenot-accessiblecurrentThe port loopback test table. This table controls the port loopback tests.
1.3.6.1.4.1.4515.1.3.13.1.1.1RowslTestsIfLoopEntrynot-accessiblecurrentThis entry is used to operate an port loopback test.
1.3.6.1.4.1.4515.1.3.13.1.1.1.1ColumnslTestsIfLoopIfIndexread-onlycurrentThe Interface Index of the port that should be loopped back.
1.3.6.1.4.1.4515.1.3.13.1.1.1.2ColumnslTestsIfLoopDurationread-writecurrentThe test duration in 1/10 Sec. The maximum allowed duration is 1 hour. After this time the port configuration returns to its original setting and the Agent aut…
1.3.6.1.4.1.4515.1.3.13.1.1.1.3ColumnslTestsIfLoopStatusread-writecurrentThis variable is used to start or stop a loopback test. In order to start a test the NMS should set the value to start(1). If the test mode is toggle, the NMS …
1.3.6.1.4.1.4515.1.3.13.1.1.1.5ColumnslTestsIfLoopTyperead-writecurrentThe loopback type: facility The received signal at this interface is looped back out through the corresponding transmitter in the return direction. terminal Th…
1.3.6.1.4.1.4515.1.3.13.1.1.1.6ColumnslTestsIfLoopModeread-writecurrentThe loopback mode: timeout In this mode the duration of the loopback is determined by the slTestsIfLoopDuration object. toggle In this mode the loopback should…
1.3.6.1.4.1.4515.1.3.13.1.1.1.7ColumnslTestsIfLoopErrorsread-onlycurrentThe prbs errors are counted only of the test succeeded.
1.3.6.1.4.1.4515.1.3.13.1.1.1.8ColumnslTestsIfLoopResultread-onlycurrentThis variable is used for prbs test result indication.
1.3.6.1.4.1.4515.1.3.13.1.1.1.9ColumnslTestsIfLoopPassedSecondsread-onlycurrentNumber of seconds passed since the test started.
1.3.6.1.4.1.4515.1.3.13.2NodeslTestsTraps
1.3.6.1.4.1.4515.1.3.13.2.0NodeslTestsTraps0
1.3.6.1.4.1.4515.1.3.13.2.0.2NotificationslTestsTrapsLoopbackTableChanged0currentA slTestsTrapsLoopbackTableChanged trap is sent when the content of slTestsIfLoopTable changes. When the loop back is deleted the returned value of slTestsIfLo…
1.3.6.1.4.1.4515.1.3.13.2.1ScalarslTestsTrapsLoopbackActiveread-onlycurrentThe Loopback is active Yes/No.
1.3.6.1.4.1.4515.1.3.13.2.2NotificationslTestsTrapsLoopbackTableChangedcurrentA slTestsTrapsLoopbackTableChanged trap is sent when the content of slTestsIfLoopTable changes. When the loop back is deleted the returned value of slTestsIfLo…