MIB Viewer

TRIPPLITE-MIB

183 objects
This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.850IdentitytrippliteThis MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.
1.3.6.1.4.1.850.1NodetrippUPS
1.3.6.1.4.1.850.1.0NodetlV11TrapsPrefix
1.3.6.1.4.1.850.1.0.100NotificationtlV11upsCriticalobsoleteUPS Critical Alarm.
1.3.6.1.4.1.850.1.0.101NotificationtlV11upsWarningobsoleteUPS Warning.
1.3.6.1.4.1.850.1.0.102NotificationtlV11upsInformationobsoleteUPS Information.
1.3.6.1.4.1.850.1.0.103NotificationtlV11upsAlarmClearedobsoleteUPS Alarm Cleared.
1.3.6.1.4.1.850.1.0.104NotificationtlV11upsAgentStartedobsoleteAgent started.
1.3.6.1.4.1.850.1.0.105NotificationtlV11upsAgentStoppedobsoleteAgent stopped.
1.3.6.1.4.1.850.1.1NodetrippUpsReceptacles
1.3.6.1.4.1.850.1.1.1ScalarupsReceptaclesNumReceptaclesread-onlyobsoleteThe number of available receptacles in this device. This variable indicates the number of rows in the receptacle table.
1.3.6.1.4.1.850.1.1.2TableupsReceptacleTablenot-accessibleobsoleteA list of receptacle table entries. The number of entries is given by the value of upsReceptaclesNumReceptacles.
1.3.6.1.4.1.850.1.1.2.1RowupsReceptacleEntrynot-accessibleobsoleteAn entry containing information applicable to a particular receptacle.
1.3.6.1.4.1.850.1.1.2.1.1ColumnupsReceptacleIndexread-onlyobsoleteThe receptacle identifier.
1.3.6.1.4.1.850.1.1.2.1.2ColumnupsReceptacleTyperead-onlyobsoleteThe type of receptacle.
1.3.6.1.4.1.850.1.1.2.1.3ColumnupsReceptacleStatusread-onlyobsoleteThe status of receptacle.
1.3.6.1.4.1.850.1.1.2.1.4ColumnupsReceptacleControlread-writeobsoleteSetting this object to 'on' will turn on the receptacle. Setting this object to 'off' will turn off the receptacle. Setting this object to 'cycle' will turn of…
1.3.6.1.4.1.850.1.2NodetrippUpsTrapInfo
1.3.6.1.4.1.850.1.2.1ScalarupsTrapCoderead-onlydeprecatedA numeric code identifiying the condition that caused the trap to be sent. If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this code will…
1.3.6.1.4.1.850.1.2.2ScalarupsTrapDescriptionread-onlydeprecatedThe description of the trap.
1.3.6.1.4.1.850.1.3NodetrippUpsEnvironment
1.3.6.1.4.1.850.1.3.1ScalarupsEnvTemperatureread-onlyobsoleteThe ambient temperature of the EnviroSense unit (1/10 Deg C).
1.3.6.1.4.1.850.1.3.2ScalarupsEnvHumidityread-onlyobsoleteThe ambient humidity of the EnviroSense unit (% Humidity).
1.3.6.1.4.1.850.1.4NodetrippUpsContacts
1.3.6.1.4.1.850.1.4.1TableupsContactTablenot-accessibleobsoleteA table of contacts attached to the EnviroSense unit.
1.3.6.1.4.1.850.1.4.1.1RowupsContactEntrynot-accessibleobsoleteAn entry containing information applicable to a particular contact.
1.3.6.1.4.1.850.1.4.1.1.1ColumnupsContactIndexread-onlyobsoleteThe contact identifier.
1.3.6.1.4.1.850.1.4.1.1.2ColumnupsContactNameread-writeobsoleteThe contact name.
1.3.6.1.4.1.850.1.4.1.1.3ColumnupsContactStatusread-onlyobsoleteThe current status of the contact.
1.3.6.1.4.1.850.1.4.1.1.4ColumnupsContactConfigread-writeobsoleteThe default configuration of the contact.
1.3.6.1.4.1.850.2NodetlEnumerations
1.3.6.1.4.1.850.2.1NodetlOperatingSystems
1.3.6.1.4.1.850.2.1.1Nodehpux9
1.3.6.1.4.1.850.2.1.2Nodesunos4
1.3.6.1.4.1.850.2.1.3Nodesolaris
1.3.6.1.4.1.850.2.1.4Nodeosf
1.3.6.1.4.1.850.2.1.5Nodeultrix
1.3.6.1.4.1.850.2.1.6Nodehpux10
1.3.6.1.4.1.850.2.1.7Nodenetbsd1
1.3.6.1.4.1.850.2.1.8Nodefreebsd
1.3.6.1.4.1.850.2.1.9Nodeirix
1.3.6.1.4.1.850.2.1.10Nodelinux
1.3.6.1.4.1.850.2.1.11Nodebsdi
1.3.6.1.4.1.850.2.1.12Nodeopenbsd
1.3.6.1.4.1.850.2.1.13Nodewin32
1.3.6.1.4.1.850.2.1.14Nodehpux11
1.3.6.1.4.1.850.2.1.50Nodewin9x
1.3.6.1.4.1.850.2.1.51Nodewinnt
1.3.6.1.4.1.850.2.1.52Nodesolspark
1.3.6.1.4.1.850.2.1.53Nodesolintel
1.3.6.1.4.1.850.2.1.54Nodeaix
1.3.6.1.4.1.850.2.1.55Nodesco
1.3.6.1.4.1.850.2.1.56Nodeosx
1.3.6.1.4.1.850.2.1.255Nodeunknown
1.3.6.1.4.1.850.20NodetlConformance
1.3.6.1.4.1.850.20.1NodetlCompliances
1.3.6.1.4.1.850.20.2NodetlGroups
1.3.6.1.4.1.850.20.2.1NodetlSubsetGroups
1.3.6.1.4.1.850.20.2.2NodetlBasicGroups
1.3.6.1.4.1.850.20.2.3NodetlFullGroups
1.3.6.1.4.1.850.20.2.3.100NodetlUpsFullGroups
1.3.6.1.4.1.850.20.2.3.100.1GrouptlUpsFullIdentGroupcurrentThe tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.2GrouptlUpsFullBatteryGroupcurrentThe tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.6NodetlUpsFullAlarmGroup
1.3.6.1.4.1.850.20.2.3.100.6.1GrouptlUpsFullAlarmObjsGroupcurrentThe tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.7GrouptlUpsFullTestGroupcurrentThe tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.8GrouptlUpsFullControlGroupcurrentThe tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.9GrouptlUpsFullConfigGroupcurrentThe tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.3.100.10GrouptlUpsFullOutletGroupcurrentThe tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's
1.3.6.1.4.1.850.20.2.4NodetlV11Groups
1.3.6.1.4.1.850.20.2.4.1GrouptlDeprecatedV11GroupobsoleteThe tlDeprecatedV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11. These objects are currently only u…
1.3.6.1.4.1.850.20.2.4.2GrouptlDeprecatedV11NotificationsGroupobsoleteThe tlDeprecatedV11NotificationsGroup defines PowerAlert version 11 notifications. These notifications are being deprecated, but may still be used when tlEngin…
1.3.6.1.4.1.850.20.2.4.3GrouptlObsoleteV11GroupobsoleteThe tlObsoleteV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs. Most of these objects are obsolete.
1.3.6.1.4.1.850.100NodetlUPS
1.3.6.1.4.1.850.100.1NodetlUpsObjects
1.3.6.1.4.1.850.100.1.1NodetlUpsIdent
1.3.6.1.4.1.850.100.1.1.1ScalartlUpsIdentUpsSoftwareChecksumread-onlycurrentA checksum for the UPS fostware.
1.3.6.1.4.1.850.100.1.1.2ScalartlUpsIdentSerialNumread-onlycurrentSerial number for the UPS.
1.3.6.1.4.1.850.100.1.1.3ScalartlUpsIdentIDread-writecurrentA user-supplied ID for the UPS.
1.3.6.1.4.1.850.100.1.1.4ScalartlUpsSnmpCardSerialNumread-onlycurrentSerial number for the UPS.
1.3.6.1.4.1.850.100.1.2NodetlUpsBattery
1.3.6.1.4.1.850.100.1.2.1ScalartlUpsBatteryAgeread-onlycurrentThe age of the battery, in the format YYYYMMDD. This is equal to the current date minus tlConfigBattReplDate.
1.3.6.1.4.1.850.100.1.2.2ScalartlUpsTemperatureFread-onlycurrentThe temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees.
1.3.6.1.4.1.850.100.1.3NodetlUpsInput
1.3.6.1.4.1.850.100.1.4NodetlUpsOutput
1.3.6.1.4.1.850.100.1.5NodetlUpsBypass
1.3.6.1.4.1.850.100.1.6NodetlUpsAlarm
1.3.6.1.4.1.850.100.1.6.1ScalartlUpsAlarmsPresentread-onlycurrentThe present number of active alarm conditions.
1.3.6.1.4.1.850.100.1.6.2TabletlUpsAlarmTablenot-accessiblecurrentA list of alarm table entries.
1.3.6.1.4.1.850.100.1.6.2.1RowtlUpsAlarmEntrynot-accessiblecurrentAn entry containing information applicable to a particular alarm.
1.3.6.1.4.1.850.100.1.6.2.1.1ColumntlUpsAlarmIdread-onlycurrentA unique identifier for an alarm condition.
1.3.6.1.4.1.850.100.1.6.2.1.2ColumntlUpsAlarmDescrread-onlycurrentA description of the alarm condition.
1.3.6.1.4.1.850.100.1.6.2.1.3ColumntlUpsAlarmTimeread-onlycurrentThe value of sysUpTime when the alarm condition was detected.
1.3.6.1.4.1.850.100.1.6.2.1.4ColumntlUpsAlarmDetailread-onlycurrentA textual description of the alarm condition.
1.3.6.1.4.1.850.100.1.6.2.1.5ColumntlUpsAlarmDeviceIdread-onlycurrentA numeric identifier for the device on which the alarm is active.
1.3.6.1.4.1.850.100.1.6.2.1.6ColumntlUpsAlarmDeviceNameread-onlycurrentA string identifier for the device on which the alarm is active.
1.3.6.1.4.1.850.100.1.6.2.1.7ColumntlUpsAlarmLocationread-onlycurrentThe location of the device on which the alarm is active.
1.3.6.1.4.1.850.100.1.6.2.1.8ColumntlUpsAlarmGroupread-onlycurrentThe category/group of this alarm.
1.3.6.1.4.1.850.100.1.6.2.1.9ColumntlUpsAlarmIpread-onlycurrentThe originating IP address associated with this alarm.
1.3.6.1.4.1.850.100.1.6.2.1.10ColumntlUpsAlarmMacread-onlycurrentThe originating mac address associated with this alarm.
1.3.6.1.4.1.850.100.1.6.3NodetlUpsWellKnownAlarms
1.3.6.1.4.1.850.100.1.6.3.1IdentitytlUpsAlarmPrimaryPowerOutagecurrentThe primary power source is not present.
1.3.6.1.4.1.850.100.1.6.3.2IdentitytlUpsAlarmSecondaryPowerOutagecurrentThe secondary power source is not present.
1.3.6.1.4.1.850.100.1.6.3.3IdentitytlUpsAlarmLoadLevelAboveThresholdcurrentThe load level is above the designated threshold.
1.3.6.1.4.1.850.100.1.6.3.4IdentitytlUpsAlarmOutputCurrentChangedcurrentThe output current changed from its last known value.
1.3.6.1.4.1.850.100.1.6.7ScalartlUpsAlarmDevNameread-onlydeprecatedThe name of the device, tlDevName, corresponding to the device that is associated with this alarm.
1.3.6.1.4.1.850.100.1.6.8ScalartlUpsAlarmDevLocationread-onlydeprecatedThe location of the device, tlDevLocation, corresponding to the device that is associated with this alarm.
1.3.6.1.4.1.850.100.1.6.9ScalartlUpsAlarmCategoryread-onlydeprecatedThe category, tlDevEvtCategory, of this alarm.
1.3.6.1.4.1.850.100.1.7NodetlUpsTest
1.3.6.1.4.1.850.100.1.7.1ScalartlUpsTestDateread-onlycurrentThe date of the last self-test run on the ups, in the format YYYYMMDD.
1.3.6.1.4.1.850.100.1.7.2ScalartlUpsTestResultsDetailread-onlycurrentResult of the last self-test run on the ups.
1.3.6.1.4.1.850.100.1.8NodetlUpsControl
1.3.6.1.4.1.850.100.1.8.1ScalartlUpsWatchdogSupportedread-onlycurrentIndicates whether or not this UPS supports a watchdog reboot.
1.3.6.1.4.1.850.100.1.8.2ScalartlUpsWatchdogSecsBeforeRebootread-writecurrentThe maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outpu…
1.3.6.1.4.1.850.100.1.8.3NodetlUpsWellKnownControls
1.3.6.1.4.1.850.100.1.8.3.1ScalartlUpsControlSelfTestread-writecurrentSet to TRUE to initiate Self Test
1.3.6.1.4.1.850.100.1.8.3.2ScalartlUpsControlRampread-writecurrentSet to TRUE to initiate Ramp
1.3.6.1.4.1.850.100.1.8.3.3ScalartlUpsControlShedread-writecurrentSet to TRUE to initiate Shed
1.3.6.1.4.1.850.100.1.8.3.4ScalartlUpsControlUpsOnread-writecurrentSet to TRUE to turn UPS on
1.3.6.1.4.1.850.100.1.8.3.5ScalartlUpsControlUpsOffread-writecurrentSet to TRUE to turn UPS off
1.3.6.1.4.1.850.100.1.9NodetlUpsConfig
1.3.6.1.4.1.850.100.1.9.1ScalartlUpsConfigBattReplDateread-writecurrentThe date on which the battery was last replaced, in the format YYYYMMDD.
1.3.6.1.4.1.850.100.1.9.2ScalartlUpsConfigTftpGetAddrread-writecurrentThe IP address of the TFTP server you wish to acquire a config ini file from, non persistent, 0.0.0.0 when empty
1.3.6.1.4.1.850.100.1.9.3ScalartlUpsConfigTftpGetAcctionread-writecurrentsetting this entry to get(1) will start a down load from the specified address, during the download this entry will read getting(2), when finished, the card wi…
1.3.6.1.4.1.850.100.1.10NodetlUpsOutlet
1.3.6.1.4.1.850.100.1.10.1ScalartlUpsOutletNumOutletsread-onlycurrentThe number of available Outlets in this device.
1.3.6.1.4.1.850.100.1.10.2TabletlUpsOutletTablenot-accessiblecurrentA list of all device Outlets for all devices.
1.3.6.1.4.1.850.100.1.10.2.1RowtlUpsOutletEntrynot-accessiblecurrentAn entry containing Outlet information applicable to a particular device managed by this agent.
1.3.6.1.4.1.850.100.1.10.2.1.1ColumntlUpsOutletIndexread-onlycurrentThis is the index number of this Outlet for the device indicated by tlDeviceIndex.
1.3.6.1.4.1.850.100.1.10.2.1.2ColumntlUpsOutletStateread-onlycurrentThe current state of the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.3ColumntlUpsOutletTyperead-onlycurrentThis is a bit field that indicates the type of this Outlet. Bit Display 0 Battery Protected 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1.3.6.1.4.1.850.100.1.10.2.1.4ColumntlUpsOutletControlread-writecurrentControls the state of the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.5ColumntlUpsOutletNameread-writecurrentA string identifying the devices attached to the output(s) of the device.
1.3.6.1.4.1.850.100.1.10.2.1.6ColumntlUpsOutletRampActionread-writecurrentThe ramp action to take on the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.7ColumntlUpsOutletRampDataTyperead-writecurrentThe type of data associated with ramp action.
1.3.6.1.4.1.850.100.1.10.2.1.8ColumntlUpsOutletRampDataread-writecurrentThe data value associated with type of ramp data.
1.3.6.1.4.1.850.100.1.10.2.1.9ColumntlUpsOutletShedActionread-writecurrentThe shed action to take on the Outlet.
1.3.6.1.4.1.850.100.1.10.2.1.10ColumntlUpsOutletShedDataTyperead-writecurrentThe type of data associated with shed action.
1.3.6.1.4.1.850.100.1.10.2.1.11ColumntlUpsOutletShedDataread-writecurrentThe data value associated with type of shed data.
1.3.6.1.4.1.850.100.1.10.2.1.12ColumntlUpsOutletGroupNdxread-writecurrenttlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped.
1.3.6.1.4.1.850.100.1.10.3TabletlUpsOutletCurrentTablenot-accessiblecurrentA list of load currents.
1.3.6.1.4.1.850.100.1.10.3.1RowtlUpsOutletCurrentEntrynot-accessiblecurrentAn entry containing Outlet current information applicable to a particular device managed by this agent.
1.3.6.1.4.1.850.100.1.10.3.1.1ColumntlUpsOutletCurrentIndexread-onlycurrentThis is the index number of this Outlet.
1.3.6.1.4.1.850.100.1.10.3.1.2ColumntlUpsOutletCurrentValueread-onlycurrentThe value of this outlet's current, represented as 0.1A
1.3.6.1.4.1.850.100.1.10.4TabletlUpsOutletPowerTablenot-accessiblecurrentA list of load power.
1.3.6.1.4.1.850.100.1.10.4.1RowtlUpsOutletPowerEntrynot-accessiblecurrentAn entry containing Outlet power information applicable to a particular device managed by this agent.
1.3.6.1.4.1.850.100.1.10.4.1.1ColumntlUpsOutletPowerIndexread-onlycurrentThis is the index number of this Outlet.
1.3.6.1.4.1.850.100.1.10.4.1.2ColumntlUpsOutletPowerValueread-onlycurrentThe value of this outlet's power in watts.
1.3.6.1.4.1.850.100.1.11NodetlUpsOutletGroup
1.3.6.1.4.1.850.100.1.11.1ScalartlUpsOutletNumOutletGroupsread-onlycurrentThe number of available Outlet Groups in this device.
1.3.6.1.4.1.850.100.1.11.2TabletlUpsOutletGroupTablenot-accessiblecurrentA list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups.
1.3.6.1.4.1.850.100.1.11.2.1RowtlUpsOutletGroupEntrynot-accessiblecurrentAn entry containing outlet group information applicable to a particular device managed by this agent
1.3.6.1.4.1.850.100.1.11.2.1.1ColumntlUpsOutletGroupIndexread-onlycurrentThis is the index number of this load group for the device.
1.3.6.1.4.1.850.100.1.11.2.1.2ColumntlUpsOutletGroupUnusedread-onlycurrentUnused placeholder
1.3.6.1.4.1.850.100.1.11.2.1.3ColumntlUpsOutletGroupNameread-writecurrentThe name of this outlet group.
1.3.6.1.4.1.850.100.1.11.2.1.4ColumntlUpsOutletGroupDescread-writecurrentA description for this outlet group.
1.3.6.1.4.1.850.100.1.11.2.1.5ColumntlUpsOutletGroupStateread-onlycurrentThe current state of the outlet group.
1.3.6.1.4.1.850.100.1.11.2.1.6ColumntlUpsOutletGroupControlread-writecurrentControls the state of every outlet associated with the group.
1.3.6.1.4.1.850.100.2NodetlUpsTraps
1.3.6.1.4.1.850.100.2.3NotificationtlUpsTrapAlarmEntryAddedcurrentThis trap is sent each time an alarm is inserted into to the alarm table.
1.3.6.1.4.1.850.100.2.3NodetlUpsTrapAlarmEntryAddedV1This trap is sent each time an alarm is inserted into to the alarm table.
1.3.6.1.4.1.850.100.2.4NotificationtlUpsTrapAlarmEntryRemovedcurrentThis trap is sent each time an alarm is removed from the alarm table.
1.3.6.1.4.1.850.100.2.4NodetlUpsTrapAlarmEntryRemovedV1This trap is sent each time an alarm is removed from the alarm table.
1.3.6.1.4.1.850.101NodetlEnviroSense
1.3.6.1.4.1.850.101.1NodetlEnvEnvironment
1.3.6.1.4.1.850.101.1.1NodetlEnvTemperatureData
1.3.6.1.4.1.850.101.1.1.1ScalartlEnvTemperatureCread-onlycurrentThe ambient temperature (C).
1.3.6.1.4.1.850.101.1.1.2ScalartlEnvTemperatureFread-onlycurrentThe ambient temperature (F).
1.3.6.1.4.1.850.101.1.1.3ScalartlEnvTemperatureLowLimitread-writecurrentThe lower alarm limit for ambient temperature (F).
1.3.6.1.4.1.850.101.1.1.4ScalartlEnvTemperatureHighLimitread-writecurrentThe upper alarm limit for ambient temperature (F).
1.3.6.1.4.1.850.101.1.1.5ScalartlEnvTemperatureInAlarmread-onlycurrentIndicates whether or not temperature is in alarm.
1.3.6.1.4.1.850.101.1.2NodetlEnvHumidityData
1.3.6.1.4.1.850.101.1.2.1ScalartlEnvHumidityread-onlycurrentThe ambient humidity (%).
1.3.6.1.4.1.850.101.1.2.2ScalartlEnvHumidityLowLimitread-writecurrentThe lower alarm limit for ambient humidity (%).
1.3.6.1.4.1.850.101.1.2.3ScalartlEnvHumidityHighLimitread-writecurrentThe upper alarm limit for ambient humidity (%).
1.3.6.1.4.1.850.101.1.2.4ScalartlEnvHumidityInAlarmread-onlycurrentIndicates whether or not humidity is in alarm.
1.3.6.1.4.1.850.101.2NodetlEnvContacts
1.3.6.1.4.1.850.101.2.1TabletlEnvContactTablenot-accessiblecurrentA table of contacts.
1.3.6.1.4.1.850.101.2.1.1RowtlEnvContactEntrynot-accessiblecurrentAn entry containing information applicable to a particular contact.
1.3.6.1.4.1.850.101.2.1.1.1ColumntlEnvContactIndexread-onlycurrentThe table row index for the contact.
1.3.6.1.4.1.850.101.2.1.1.2ColumntlEnvContactNameread-writecurrentThe name or description of the contact.
1.3.6.1.4.1.850.101.2.1.1.3ColumntlEnvContactStatusread-onlycurrentThe current status of the contact.
1.3.6.1.4.1.850.101.2.1.1.4ColumntlEnvContactConfigread-writecurrentThe configuration of the contact.