TRIPPLITE-MIB
183 objects
This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.
Imported Objects
| SNMPv2-CONF | NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | enterprises Gauge32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE |
| SNMPv2-TC | AutonomousType DateAndTime DisplayString RowStatus TimeInterval TimeStamp TruthValue VariablePointer |
| UPS-MIB | NonNegativeInteger PositiveInteger |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.850 | Identitytripplite | This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software. | ||
| 1.3.6.1.4.1.850.1 | NodetrippUPS | |||
| 1.3.6.1.4.1.850.1.0 | NodetlV11TrapsPrefix | |||
| 1.3.6.1.4.1.850.1.0.100 | NotificationtlV11upsCritical | obsolete | UPS Critical Alarm. | |
| 1.3.6.1.4.1.850.1.0.101 | NotificationtlV11upsWarning | obsolete | UPS Warning. | |
| 1.3.6.1.4.1.850.1.0.102 | NotificationtlV11upsInformation | obsolete | UPS Information. | |
| 1.3.6.1.4.1.850.1.0.103 | NotificationtlV11upsAlarmCleared | obsolete | UPS Alarm Cleared. | |
| 1.3.6.1.4.1.850.1.0.104 | NotificationtlV11upsAgentStarted | obsolete | Agent started. | |
| 1.3.6.1.4.1.850.1.0.105 | NotificationtlV11upsAgentStopped | obsolete | Agent stopped. | |
| 1.3.6.1.4.1.850.1.1 | NodetrippUpsReceptacles | |||
| 1.3.6.1.4.1.850.1.1.1 | ScalarupsReceptaclesNumReceptacles | read-only | obsolete | The number of available receptacles in this device. This variable indicates the number of rows in the receptacle table. |
| 1.3.6.1.4.1.850.1.1.2 | TableupsReceptacleTable | not-accessible | obsolete | A list of receptacle table entries. The number of entries is given by the value of upsReceptaclesNumReceptacles. |
| 1.3.6.1.4.1.850.1.1.2.1 | RowupsReceptacleEntry | not-accessible | obsolete | An entry containing information applicable to a particular receptacle. |
| 1.3.6.1.4.1.850.1.1.2.1.1 | ColumnupsReceptacleIndex | read-only | obsolete | The receptacle identifier. |
| 1.3.6.1.4.1.850.1.1.2.1.2 | ColumnupsReceptacleType | read-only | obsolete | The type of receptacle. |
| 1.3.6.1.4.1.850.1.1.2.1.3 | ColumnupsReceptacleStatus | read-only | obsolete | The status of receptacle. |
| 1.3.6.1.4.1.850.1.1.2.1.4 | ColumnupsReceptacleControl | read-write | obsolete | Setting this object to 'on' will turn on the receptacle. Setting this object to 'off' will turn off the receptacle. Setting this object to 'cycle' will turn of… |
| 1.3.6.1.4.1.850.1.2 | NodetrippUpsTrapInfo | |||
| 1.3.6.1.4.1.850.1.2.1 | ScalarupsTrapCode | read-only | deprecated | A numeric code identifiying the condition that caused the trap to be sent. If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this code will… |
| 1.3.6.1.4.1.850.1.2.2 | ScalarupsTrapDescription | read-only | deprecated | The description of the trap. |
| 1.3.6.1.4.1.850.1.3 | NodetrippUpsEnvironment | |||
| 1.3.6.1.4.1.850.1.3.1 | ScalarupsEnvTemperature | read-only | obsolete | The ambient temperature of the EnviroSense unit (1/10 Deg C). |
| 1.3.6.1.4.1.850.1.3.2 | ScalarupsEnvHumidity | read-only | obsolete | The ambient humidity of the EnviroSense unit (% Humidity). |
| 1.3.6.1.4.1.850.1.4 | NodetrippUpsContacts | |||
| 1.3.6.1.4.1.850.1.4.1 | TableupsContactTable | not-accessible | obsolete | A table of contacts attached to the EnviroSense unit. |
| 1.3.6.1.4.1.850.1.4.1.1 | RowupsContactEntry | not-accessible | obsolete | An entry containing information applicable to a particular contact. |
| 1.3.6.1.4.1.850.1.4.1.1.1 | ColumnupsContactIndex | read-only | obsolete | The contact identifier. |
| 1.3.6.1.4.1.850.1.4.1.1.2 | ColumnupsContactName | read-write | obsolete | The contact name. |
| 1.3.6.1.4.1.850.1.4.1.1.3 | ColumnupsContactStatus | read-only | obsolete | The current status of the contact. |
| 1.3.6.1.4.1.850.1.4.1.1.4 | ColumnupsContactConfig | read-write | obsolete | The default configuration of the contact. |
| 1.3.6.1.4.1.850.2 | NodetlEnumerations | |||
| 1.3.6.1.4.1.850.2.1 | NodetlOperatingSystems | |||
| 1.3.6.1.4.1.850.2.1.1 | Nodehpux9 | |||
| 1.3.6.1.4.1.850.2.1.2 | Nodesunos4 | |||
| 1.3.6.1.4.1.850.2.1.3 | Nodesolaris | |||
| 1.3.6.1.4.1.850.2.1.4 | Nodeosf | |||
| 1.3.6.1.4.1.850.2.1.5 | Nodeultrix | |||
| 1.3.6.1.4.1.850.2.1.6 | Nodehpux10 | |||
| 1.3.6.1.4.1.850.2.1.7 | Nodenetbsd1 | |||
| 1.3.6.1.4.1.850.2.1.8 | Nodefreebsd | |||
| 1.3.6.1.4.1.850.2.1.9 | Nodeirix | |||
| 1.3.6.1.4.1.850.2.1.10 | Nodelinux | |||
| 1.3.6.1.4.1.850.2.1.11 | Nodebsdi | |||
| 1.3.6.1.4.1.850.2.1.12 | Nodeopenbsd | |||
| 1.3.6.1.4.1.850.2.1.13 | Nodewin32 | |||
| 1.3.6.1.4.1.850.2.1.14 | Nodehpux11 | |||
| 1.3.6.1.4.1.850.2.1.50 | Nodewin9x | |||
| 1.3.6.1.4.1.850.2.1.51 | Nodewinnt | |||
| 1.3.6.1.4.1.850.2.1.52 | Nodesolspark | |||
| 1.3.6.1.4.1.850.2.1.53 | Nodesolintel | |||
| 1.3.6.1.4.1.850.2.1.54 | Nodeaix | |||
| 1.3.6.1.4.1.850.2.1.55 | Nodesco | |||
| 1.3.6.1.4.1.850.2.1.56 | Nodeosx | |||
| 1.3.6.1.4.1.850.2.1.255 | Nodeunknown | |||
| 1.3.6.1.4.1.850.20 | NodetlConformance | |||
| 1.3.6.1.4.1.850.20.1 | NodetlCompliances | |||
| 1.3.6.1.4.1.850.20.2 | NodetlGroups | |||
| 1.3.6.1.4.1.850.20.2.1 | NodetlSubsetGroups | |||
| 1.3.6.1.4.1.850.20.2.2 | NodetlBasicGroups | |||
| 1.3.6.1.4.1.850.20.2.3 | NodetlFullGroups | |||
| 1.3.6.1.4.1.850.20.2.3.100 | NodetlUpsFullGroups | |||
| 1.3.6.1.4.1.850.20.2.3.100.1 | GrouptlUpsFullIdentGroup | current | The tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.3.100.2 | GrouptlUpsFullBatteryGroup | current | The tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.3.100.6 | NodetlUpsFullAlarmGroup | |||
| 1.3.6.1.4.1.850.20.2.3.100.6.1 | GrouptlUpsFullAlarmObjsGroup | current | The tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.3.100.7 | GrouptlUpsFullTestGroup | current | The tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.3.100.8 | GrouptlUpsFullControlGroup | current | The tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.3.100.9 | GrouptlUpsFullConfigGroup | current | The tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.3.100.10 | GrouptlUpsFullOutletGroup | current | The tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's | |
| 1.3.6.1.4.1.850.20.2.4 | NodetlV11Groups | |||
| 1.3.6.1.4.1.850.20.2.4.1 | GrouptlDeprecatedV11Group | obsolete | The tlDeprecatedV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11. These objects are currently only u… | |
| 1.3.6.1.4.1.850.20.2.4.2 | GrouptlDeprecatedV11NotificationsGroup | obsolete | The tlDeprecatedV11NotificationsGroup defines PowerAlert version 11 notifications. These notifications are being deprecated, but may still be used when tlEngin… | |
| 1.3.6.1.4.1.850.20.2.4.3 | GrouptlObsoleteV11Group | obsolete | The tlObsoleteV11Group defines objects which were used by Sinetica SNMP cards on Tripplite UPSs. Most of these objects are obsolete. | |
| 1.3.6.1.4.1.850.100 | NodetlUPS | |||
| 1.3.6.1.4.1.850.100.1 | NodetlUpsObjects | |||
| 1.3.6.1.4.1.850.100.1.1 | NodetlUpsIdent | |||
| 1.3.6.1.4.1.850.100.1.1.1 | ScalartlUpsIdentUpsSoftwareChecksum | read-only | current | A checksum for the UPS fostware. |
| 1.3.6.1.4.1.850.100.1.1.2 | ScalartlUpsIdentSerialNum | read-only | current | Serial number for the UPS. |
| 1.3.6.1.4.1.850.100.1.1.3 | ScalartlUpsIdentID | read-write | current | A user-supplied ID for the UPS. |
| 1.3.6.1.4.1.850.100.1.1.4 | ScalartlUpsSnmpCardSerialNum | read-only | current | Serial number for the UPS. |
| 1.3.6.1.4.1.850.100.1.2 | NodetlUpsBattery | |||
| 1.3.6.1.4.1.850.100.1.2.1 | ScalartlUpsBatteryAge | read-only | current | The age of the battery, in the format YYYYMMDD. This is equal to the current date minus tlConfigBattReplDate. |
| 1.3.6.1.4.1.850.100.1.2.2 | ScalartlUpsTemperatureF | read-only | current | The temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees. |
| 1.3.6.1.4.1.850.100.1.3 | NodetlUpsInput | |||
| 1.3.6.1.4.1.850.100.1.4 | NodetlUpsOutput | |||
| 1.3.6.1.4.1.850.100.1.5 | NodetlUpsBypass | |||
| 1.3.6.1.4.1.850.100.1.6 | NodetlUpsAlarm | |||
| 1.3.6.1.4.1.850.100.1.6.1 | ScalartlUpsAlarmsPresent | read-only | current | The present number of active alarm conditions. |
| 1.3.6.1.4.1.850.100.1.6.2 | TabletlUpsAlarmTable | not-accessible | current | A list of alarm table entries. |
| 1.3.6.1.4.1.850.100.1.6.2.1 | RowtlUpsAlarmEntry | not-accessible | current | An entry containing information applicable to a particular alarm. |
| 1.3.6.1.4.1.850.100.1.6.2.1.1 | ColumntlUpsAlarmId | read-only | current | A unique identifier for an alarm condition. |
| 1.3.6.1.4.1.850.100.1.6.2.1.2 | ColumntlUpsAlarmDescr | read-only | current | A description of the alarm condition. |
| 1.3.6.1.4.1.850.100.1.6.2.1.3 | ColumntlUpsAlarmTime | read-only | current | The value of sysUpTime when the alarm condition was detected. |
| 1.3.6.1.4.1.850.100.1.6.2.1.4 | ColumntlUpsAlarmDetail | read-only | current | A textual description of the alarm condition. |
| 1.3.6.1.4.1.850.100.1.6.2.1.5 | ColumntlUpsAlarmDeviceId | read-only | current | A numeric identifier for the device on which the alarm is active. |
| 1.3.6.1.4.1.850.100.1.6.2.1.6 | ColumntlUpsAlarmDeviceName | read-only | current | A string identifier for the device on which the alarm is active. |
| 1.3.6.1.4.1.850.100.1.6.2.1.7 | ColumntlUpsAlarmLocation | read-only | current | The location of the device on which the alarm is active. |
| 1.3.6.1.4.1.850.100.1.6.2.1.8 | ColumntlUpsAlarmGroup | read-only | current | The category/group of this alarm. |
| 1.3.6.1.4.1.850.100.1.6.2.1.9 | ColumntlUpsAlarmIp | read-only | current | The originating IP address associated with this alarm. |
| 1.3.6.1.4.1.850.100.1.6.2.1.10 | ColumntlUpsAlarmMac | read-only | current | The originating mac address associated with this alarm. |
| 1.3.6.1.4.1.850.100.1.6.3 | NodetlUpsWellKnownAlarms | |||
| 1.3.6.1.4.1.850.100.1.6.3.1 | IdentitytlUpsAlarmPrimaryPowerOutage | current | The primary power source is not present. | |
| 1.3.6.1.4.1.850.100.1.6.3.2 | IdentitytlUpsAlarmSecondaryPowerOutage | current | The secondary power source is not present. | |
| 1.3.6.1.4.1.850.100.1.6.3.3 | IdentitytlUpsAlarmLoadLevelAboveThreshold | current | The load level is above the designated threshold. | |
| 1.3.6.1.4.1.850.100.1.6.3.4 | IdentitytlUpsAlarmOutputCurrentChanged | current | The output current changed from its last known value. | |
| 1.3.6.1.4.1.850.100.1.6.7 | ScalartlUpsAlarmDevName | read-only | deprecated | The name of the device, tlDevName, corresponding to the device that is associated with this alarm. |
| 1.3.6.1.4.1.850.100.1.6.8 | ScalartlUpsAlarmDevLocation | read-only | deprecated | The location of the device, tlDevLocation, corresponding to the device that is associated with this alarm. |
| 1.3.6.1.4.1.850.100.1.6.9 | ScalartlUpsAlarmCategory | read-only | deprecated | The category, tlDevEvtCategory, of this alarm. |
| 1.3.6.1.4.1.850.100.1.7 | NodetlUpsTest | |||
| 1.3.6.1.4.1.850.100.1.7.1 | ScalartlUpsTestDate | read-only | current | The date of the last self-test run on the ups, in the format YYYYMMDD. |
| 1.3.6.1.4.1.850.100.1.7.2 | ScalartlUpsTestResultsDetail | read-only | current | Result of the last self-test run on the ups. |
| 1.3.6.1.4.1.850.100.1.8 | NodetlUpsControl | |||
| 1.3.6.1.4.1.850.100.1.8.1 | ScalartlUpsWatchdogSupported | read-only | current | Indicates whether or not this UPS supports a watchdog reboot. |
| 1.3.6.1.4.1.850.100.1.8.2 | ScalartlUpsWatchdogSecsBeforeReboot | read-write | current | The maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outpu… |
| 1.3.6.1.4.1.850.100.1.8.3 | NodetlUpsWellKnownControls | |||
| 1.3.6.1.4.1.850.100.1.8.3.1 | ScalartlUpsControlSelfTest | read-write | current | Set to TRUE to initiate Self Test |
| 1.3.6.1.4.1.850.100.1.8.3.2 | ScalartlUpsControlRamp | read-write | current | Set to TRUE to initiate Ramp |
| 1.3.6.1.4.1.850.100.1.8.3.3 | ScalartlUpsControlShed | read-write | current | Set to TRUE to initiate Shed |
| 1.3.6.1.4.1.850.100.1.8.3.4 | ScalartlUpsControlUpsOn | read-write | current | Set to TRUE to turn UPS on |
| 1.3.6.1.4.1.850.100.1.8.3.5 | ScalartlUpsControlUpsOff | read-write | current | Set to TRUE to turn UPS off |
| 1.3.6.1.4.1.850.100.1.9 | NodetlUpsConfig | |||
| 1.3.6.1.4.1.850.100.1.9.1 | ScalartlUpsConfigBattReplDate | read-write | current | The date on which the battery was last replaced, in the format YYYYMMDD. |
| 1.3.6.1.4.1.850.100.1.9.2 | ScalartlUpsConfigTftpGetAddr | read-write | current | The IP address of the TFTP server you wish to acquire a config ini file from, non persistent, 0.0.0.0 when empty |
| 1.3.6.1.4.1.850.100.1.9.3 | ScalartlUpsConfigTftpGetAcction | read-write | current | setting this entry to get(1) will start a down load from the specified address, during the download this entry will read getting(2), when finished, the card wi… |
| 1.3.6.1.4.1.850.100.1.10 | NodetlUpsOutlet | |||
| 1.3.6.1.4.1.850.100.1.10.1 | ScalartlUpsOutletNumOutlets | read-only | current | The number of available Outlets in this device. |
| 1.3.6.1.4.1.850.100.1.10.2 | TabletlUpsOutletTable | not-accessible | current | A list of all device Outlets for all devices. |
| 1.3.6.1.4.1.850.100.1.10.2.1 | RowtlUpsOutletEntry | not-accessible | current | An entry containing Outlet information applicable to a particular device managed by this agent. |
| 1.3.6.1.4.1.850.100.1.10.2.1.1 | ColumntlUpsOutletIndex | read-only | current | This is the index number of this Outlet for the device indicated by tlDeviceIndex. |
| 1.3.6.1.4.1.850.100.1.10.2.1.2 | ColumntlUpsOutletState | read-only | current | The current state of the Outlet. |
| 1.3.6.1.4.1.850.100.1.10.2.1.3 | ColumntlUpsOutletType | read-only | current | This is a bit field that indicates the type of this Outlet. Bit Display 0 Battery Protected 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15 |
| 1.3.6.1.4.1.850.100.1.10.2.1.4 | ColumntlUpsOutletControl | read-write | current | Controls the state of the Outlet. |
| 1.3.6.1.4.1.850.100.1.10.2.1.5 | ColumntlUpsOutletName | read-write | current | A string identifying the devices attached to the output(s) of the device. |
| 1.3.6.1.4.1.850.100.1.10.2.1.6 | ColumntlUpsOutletRampAction | read-write | current | The ramp action to take on the Outlet. |
| 1.3.6.1.4.1.850.100.1.10.2.1.7 | ColumntlUpsOutletRampDataType | read-write | current | The type of data associated with ramp action. |
| 1.3.6.1.4.1.850.100.1.10.2.1.8 | ColumntlUpsOutletRampData | read-write | current | The data value associated with type of ramp data. |
| 1.3.6.1.4.1.850.100.1.10.2.1.9 | ColumntlUpsOutletShedAction | read-write | current | The shed action to take on the Outlet. |
| 1.3.6.1.4.1.850.100.1.10.2.1.10 | ColumntlUpsOutletShedDataType | read-write | current | The type of data associated with shed action. |
| 1.3.6.1.4.1.850.100.1.10.2.1.11 | ColumntlUpsOutletShedData | read-write | current | The data value associated with type of shed data. |
| 1.3.6.1.4.1.850.100.1.10.2.1.12 | ColumntlUpsOutletGroupNdx | read-write | current | tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped. |
| 1.3.6.1.4.1.850.100.1.10.3 | TabletlUpsOutletCurrentTable | not-accessible | current | A list of load currents. |
| 1.3.6.1.4.1.850.100.1.10.3.1 | RowtlUpsOutletCurrentEntry | not-accessible | current | An entry containing Outlet current information applicable to a particular device managed by this agent. |
| 1.3.6.1.4.1.850.100.1.10.3.1.1 | ColumntlUpsOutletCurrentIndex | read-only | current | This is the index number of this Outlet. |
| 1.3.6.1.4.1.850.100.1.10.3.1.2 | ColumntlUpsOutletCurrentValue | read-only | current | The value of this outlet's current, represented as 0.1A |
| 1.3.6.1.4.1.850.100.1.10.4 | TabletlUpsOutletPowerTable | not-accessible | current | A list of load power. |
| 1.3.6.1.4.1.850.100.1.10.4.1 | RowtlUpsOutletPowerEntry | not-accessible | current | An entry containing Outlet power information applicable to a particular device managed by this agent. |
| 1.3.6.1.4.1.850.100.1.10.4.1.1 | ColumntlUpsOutletPowerIndex | read-only | current | This is the index number of this Outlet. |
| 1.3.6.1.4.1.850.100.1.10.4.1.2 | ColumntlUpsOutletPowerValue | read-only | current | The value of this outlet's power in watts. |
| 1.3.6.1.4.1.850.100.1.11 | NodetlUpsOutletGroup | |||
| 1.3.6.1.4.1.850.100.1.11.1 | ScalartlUpsOutletNumOutletGroups | read-only | current | The number of available Outlet Groups in this device. |
| 1.3.6.1.4.1.850.100.1.11.2 | TabletlUpsOutletGroupTable | not-accessible | current | A list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups. |
| 1.3.6.1.4.1.850.100.1.11.2.1 | RowtlUpsOutletGroupEntry | not-accessible | current | An entry containing outlet group information applicable to a particular device managed by this agent |
| 1.3.6.1.4.1.850.100.1.11.2.1.1 | ColumntlUpsOutletGroupIndex | read-only | current | This is the index number of this load group for the device. |
| 1.3.6.1.4.1.850.100.1.11.2.1.2 | ColumntlUpsOutletGroupUnused | read-only | current | Unused placeholder |
| 1.3.6.1.4.1.850.100.1.11.2.1.3 | ColumntlUpsOutletGroupName | read-write | current | The name of this outlet group. |
| 1.3.6.1.4.1.850.100.1.11.2.1.4 | ColumntlUpsOutletGroupDesc | read-write | current | A description for this outlet group. |
| 1.3.6.1.4.1.850.100.1.11.2.1.5 | ColumntlUpsOutletGroupState | read-only | current | The current state of the outlet group. |
| 1.3.6.1.4.1.850.100.1.11.2.1.6 | ColumntlUpsOutletGroupControl | read-write | current | Controls the state of every outlet associated with the group. |
| 1.3.6.1.4.1.850.100.2 | NodetlUpsTraps | |||
| 1.3.6.1.4.1.850.100.2.3 | NotificationtlUpsTrapAlarmEntryAdded | current | This trap is sent each time an alarm is inserted into to the alarm table. | |
| 1.3.6.1.4.1.850.100.2.3 | NodetlUpsTrapAlarmEntryAddedV1 | This trap is sent each time an alarm is inserted into to the alarm table. | ||
| 1.3.6.1.4.1.850.100.2.4 | NotificationtlUpsTrapAlarmEntryRemoved | current | This trap is sent each time an alarm is removed from the alarm table. | |
| 1.3.6.1.4.1.850.100.2.4 | NodetlUpsTrapAlarmEntryRemovedV1 | This trap is sent each time an alarm is removed from the alarm table. | ||
| 1.3.6.1.4.1.850.101 | NodetlEnviroSense | |||
| 1.3.6.1.4.1.850.101.1 | NodetlEnvEnvironment | |||
| 1.3.6.1.4.1.850.101.1.1 | NodetlEnvTemperatureData | |||
| 1.3.6.1.4.1.850.101.1.1.1 | ScalartlEnvTemperatureC | read-only | current | The ambient temperature (C). |
| 1.3.6.1.4.1.850.101.1.1.2 | ScalartlEnvTemperatureF | read-only | current | The ambient temperature (F). |
| 1.3.6.1.4.1.850.101.1.1.3 | ScalartlEnvTemperatureLowLimit | read-write | current | The lower alarm limit for ambient temperature (F). |
| 1.3.6.1.4.1.850.101.1.1.4 | ScalartlEnvTemperatureHighLimit | read-write | current | The upper alarm limit for ambient temperature (F). |
| 1.3.6.1.4.1.850.101.1.1.5 | ScalartlEnvTemperatureInAlarm | read-only | current | Indicates whether or not temperature is in alarm. |
| 1.3.6.1.4.1.850.101.1.2 | NodetlEnvHumidityData | |||
| 1.3.6.1.4.1.850.101.1.2.1 | ScalartlEnvHumidity | read-only | current | The ambient humidity (%). |
| 1.3.6.1.4.1.850.101.1.2.2 | ScalartlEnvHumidityLowLimit | read-write | current | The lower alarm limit for ambient humidity (%). |
| 1.3.6.1.4.1.850.101.1.2.3 | ScalartlEnvHumidityHighLimit | read-write | current | The upper alarm limit for ambient humidity (%). |
| 1.3.6.1.4.1.850.101.1.2.4 | ScalartlEnvHumidityInAlarm | read-only | current | Indicates whether or not humidity is in alarm. |
| 1.3.6.1.4.1.850.101.2 | NodetlEnvContacts | |||
| 1.3.6.1.4.1.850.101.2.1 | TabletlEnvContactTable | not-accessible | current | A table of contacts. |
| 1.3.6.1.4.1.850.101.2.1.1 | RowtlEnvContactEntry | not-accessible | current | An entry containing information applicable to a particular contact. |
| 1.3.6.1.4.1.850.101.2.1.1.1 | ColumntlEnvContactIndex | read-only | current | The table row index for the contact. |
| 1.3.6.1.4.1.850.101.2.1.1.2 | ColumntlEnvContactName | read-write | current | The name or description of the contact. |
| 1.3.6.1.4.1.850.101.2.1.1.3 | ColumntlEnvContactStatus | read-only | current | The current status of the contact. |
| 1.3.6.1.4.1.850.101.2.1.1.4 | ColumntlEnvContactConfig | read-write | current | The configuration of the contact. |