smartLion
55 objects
The MIB module for Hirschmann Control Room Switch
Imported Objects
| HMPRIV-MGMT-SNMP-MIB | hirschmann |
| RFC1155-SMI | internet |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.248.13 | Nodehiway | |||
| 1.3.6.1.4.1.248.13.8 | NodecontrolRoomSwitch | |||
| 1.3.6.1.4.1.248.13.8.1 | NodesmartLion | |||
| 1.3.6.1.4.1.248.13.8.1.0 | Identitycontact | The MIB module for Hirschmann Control Room Switch | ||
| 1.3.6.1.4.1.248.13.8.1.1 | NodeswFan1StatusChangeTrap | This trap is sent if the status of fan 1 has changed | ||
| 1.3.6.1.4.1.248.13.8.1.1 | NodeswitchInfo | |||
| 1.3.6.1.4.1.248.13.8.1.1.1 | ScalarswitchNumber | read-only | current | The total number of switches present on this system. |
| 1.3.6.1.4.1.248.13.8.1.1.2 | TableswitchInfoTable | not-accessible | current | Table of descriptive and status information about switches in this system. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1 | RowswitchInfoEntry | not-accessible | current | An entry in the table, containing information about a single switch in this system. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.1 | ColumnswUnitIndex | not-accessible | current | This object identifies the switch within the system for which this entry contains information. This value can never be greater than switchNumber. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.2 | ColumnswMainBoardHwVer | read-only | current | Hardware(PCB) version of the main board. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.3 | ColumnswMainBoardFwVer | read-only | current | Firmware version of the main board. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.4 | ColumnswAgentBoardHwVer | read-only | current | Hardware version of the agent board. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.5 | ColumnswAgentBoardFwVer | read-only | current | Firmware version of the agent board. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.6 | ColumnswAgentBoardPOSTCodeVer | read-only | current | POST code version of the agent board. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.7 | ColumnswPortNumber | read-only | current | The total port number of this switch ( including expansion slot). |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.8 | ColumnswPowerStatus | read-only | current | Indicates the switch using internalPower(1), redundantPower(2) or both(3) |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.9 | ColumnswExpansionSlot1 | read-only | current | Type of expansion module in this switch slot 1. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.10 | ColumnswExpansionSlot2 | read-only | current | Type of expansion module in this switch slot 2. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.11 | ColumnswRoleInSystem | read-only | current | Indicates the switch is master(1), backupMaster(2) or slave(3) in this system. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.12 | ColumnswFan1Status | read-only | current | Indicates the switch fan 1 is working properly or not. |
| 1.3.6.1.4.1.248.13.8.1.1.2.1.13 | ColumnswFan2Status | read-only | current | Indicates the switch fan 2 is working properly or not. |
| 1.3.6.1.4.1.248.13.8.1.2 | NodeswFan2StatusChangeTrap | This trap is sent if the status of fan 2 has changed | ||
| 1.3.6.1.4.1.248.13.8.1.2 | NodeswitchPortMgt | |||
| 1.3.6.1.4.1.248.13.8.1.2.1 | TableswitchPortMgtTable | not-accessible | current | Table of descriptive and status information about configuration of each switch ports(including expansion slot) in this system. |
| 1.3.6.1.4.1.248.13.8.1.2.1.1 | RowswitchPortMgtEntry | not-accessible | current | An entry in the table, containing information about configuration in one switch port of the switch. |
| 1.3.6.1.4.1.248.13.8.1.2.1.1.1 | ColumnswPortMgtIndex | not-accessible | current | This object identifies the port within the switch for which this entry contains information. |
| 1.3.6.1.4.1.248.13.8.1.2.1.1.2 | ColumnswPortMgtPortType | read-only | current | Indicates the port type. |
| 1.3.6.1.4.1.248.13.8.1.2.1.1.3 | ColumnswPortMgtSpeedDpxAdmin | read-write | current | Set the port speed and duplex mode as follows: halfDuplex10(1) - 10Mbps and half duplex mode fullDuplex10(2) - 10Mbps and full duplex mode halfDuplex100(3) - 1… |
| 1.3.6.1.4.1.248.13.8.1.2.1.1.4 | ColumnswPortMgtSpeedDpxInUse | read-only | current | The operating speed and duplex mode of the switched port. |
| 1.3.6.1.4.1.248.13.8.1.2.1.1.5 | ColumnswPortMgtFlowCtrlAdmin | read-write | current | (1) Flow control mechanism is enabled. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPr… |
| 1.3.6.1.4.1.248.13.8.1.2.1.1.6 | ColumnswPortMgtFlowCtrlInUse | read-only | current | (1) BackPressure flow control machanism is used. (2) IEEE 802.3 flow control machanism is used. (3) Flow control mechanism is disabled. |
| 1.3.6.1.4.1.248.13.8.1.3 | NodesystemSTAMgt | |||
| 1.3.6.1.4.1.248.13.8.1.3.1 | ScalarsystemSTAStatus | read-write | current | Global spanning tree status. (1) Spanning tree protocol is enabled. (2) Spanning tree protocol is disabled. |
| 1.3.6.1.4.1.248.13.8.1.4 | NodetftpDownloadMgt | |||
| 1.3.6.1.4.1.248.13.8.1.4.1 | ScalartftpDownloadServerIP | read-write | current | The IP address of a TFTP server from which a firmware image can be downloaded. |
| 1.3.6.1.4.1.248.13.8.1.4.2 | ScalartftpDownloadAgentBoardFwFileName | read-write | current | |
| 1.3.6.1.4.1.248.13.8.1.4.3 | ScalartftpDownloadAgentBoardFwDownloadFunction | read-write | current | BackupConfiguration(1):Back up switch configuration to tftp server and saving as a file. RestoreConfiguration(2):Restore configuration file from tftp server to… |
| 1.3.6.1.4.1.248.13.8.1.4.4 | ScalartftpDownloadStatus | read-write | current | Setting this object to active(1) triger the TFTP download action. Setting this object to notActive(2) has no effect. The system always returns the value notAct… |
| 1.3.6.1.4.1.248.13.8.1.5 | NoderestartMgt | |||
| 1.3.6.1.4.1.248.13.8.1.5.1 | ScalarrestartOptionPOST | read-write | current | Setting this object as enabled. The system will do POST when it restart |
| 1.3.6.1.4.1.248.13.8.1.5.2 | ScalarrestartOptionReloadFactoryDefault | read-write | current | Setting this object as enabled. The system will do factory reset when it restart |
| 1.3.6.1.4.1.248.13.8.1.5.3 | ScalarrestartOptionKeepIpSetting | read-write | current | Setting this object as enabled. The system will keep IP setting when it do factory reset. |
| 1.3.6.1.4.1.248.13.8.1.5.4 | ScalarrestartOptionKeepUserAuthentication | read-write | current | Setting this object as enabled. The system will keep user authentication setting when it do factory reset. |
| 1.3.6.1.4.1.248.13.8.1.5.5 | ScalarrestartAction | read-write | current | Setting this object to active(1) triger the system restart. Setting this object to notActive(2) has no effect. The system always returns the value notActive(2)… |
| 1.3.6.1.4.1.248.13.8.1.6 | NodeportMirrorMgt | |||
| 1.3.6.1.4.1.248.13.8.1.6.1 | ScalarportMirrorStatus | read-write | current | Port mirroring function status. (1) mirroring function is enabled. (2) mirroring function is disabled. |
| 1.3.6.1.4.1.248.13.8.1.6.2 | ScalarportMirrorSnifferPort | read-write | current | Port Id(1~26) of sniffer port to which all frames to/from mirrored ports are sent. Frames are only mirrored if the portMirrorStatus object is set to enabled(1). |
| 1.3.6.1.4.1.248.13.8.1.6.3 | ScalarportMirrorMirroredPort | read-write | current | The set of ports which are mirrored. The traffic of mirrored port will be 'copied' to sniffer port. |
| 1.3.6.1.4.1.248.13.8.1.6.4 | ScalarportMirrorMode | read-write | current | Port mirroring function mode. (1) mirroring rx and tx frame. (2) mirroring rx frame. (3) mirroring tx frame. |
| 1.3.6.1.4.1.248.13.8.1.7 | NodeigmpMgt | |||
| 1.3.6.1.4.1.248.13.8.1.7.1 | ScalarigmpStatus | read-write | current | Parameter to enable or disable IGMP snooping on the device. When enabled, the device will examine IGMP packets and set up filters for IGMP ports. |
| 1.3.6.1.4.1.248.13.8.1.7.2 | ScalarigmpQueryCount | read-write | current | Maximum number of queries that have not been heard on the system before the system starts taking action to solicit reports. |
| 1.3.6.1.4.1.248.13.8.1.7.3 | ScalarigmpReportDelay | read-write | current | Timeout value (seconds) between IGMP reports received on a port for an IP Multicast Address that can pass before the system sends an IGMP Query out the port an… |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING (SIZE (0..255)) PortList ::= OCTET STRING | current |