MIB Viewer

a3ComSysTokenRingPortACErrors

OBJECT-TYPE
1.3.6.1.4.1.43.29.4.13.2.1.10
Access
read-only
Status
mandatory
Sub-identifiers
0
This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
Counter