MIB Viewer

acAnalogFxsMinFlashHookTime

OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.8.1.3.1.4
Access
read-write
Status
current
Sub-identifiers
0
Sets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIME
Unsigned32 (25..300)