MIB Viewer

acVoiceECToneDetector

OBJECT-TYPE
1.3.6.1.4.1.5003.9.10.4.1.2.3.4
Access
read-write
Status
current
Sub-identifiers
0
Used to configure the Echo Canceler Tone Detector. Detects a 2100 Hz tone at the input signal to the TDM (received signal). Improves Echo Canceler operation accordingly. Detects 2100, 2100 with phase reversals and 2100 with AM. Improves the operation of the Echo Canceler by slowing adaptation when the signal is detected. This data is also used by the fax state machine. 0 = Disable 1 = Enable. Access: Online. AC INI-Param: ECEnableToneDetector
INTEGER { disable(0) , enable(1) }