MIB Viewer

adslLineCodingGainOffset

OBJECT-TYPE
1.3.6.1.4.1.13464.1.5.1.1.1.1.19
Access
read-write
Status
current
Sub-identifiers
0
This parameter allows the user to control the Coding Gain of the CPE of the modem. The coding gain range is limited between 0dB and 7dB, a value of -1 lets the CPE choose the coding gain itself. The coding gain is expressed in entire dBs. The default value is -1.
INTEGER (-1..7)