MIB Viewer

apexAutoRebootEnable

OBJECT-TYPE
1.3.6.1.4.1.1166.1.31.1.1.1.4
Access
read-write
Status
current
Source
APEX-MIB
Sub-identifiers
0
Setting to 'enabled' allows the APEX to automatically reboot when specific APEX hardware errors occur. Setting this to Enabled will cause the APEX to automatically reboot upon specific HW faults, such as a GigE processor crash, or upon a Host processor watchdog event. When disabled, HW faults and watchdog events will not cause an automatic reboot. This is useful when it is necessary to debug the event (to allow time to gather status prior to manually rebooting). Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter. @Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(config.ini, type='ini')
EnableDisableTYPE