iso/org/dod/internet/private/enterprises/.1166/.1/apex/.7/.1/.7/apexGbeConfigInterfaceRedundancyTable/apexGbeConfigInterfaceRedundancyEntry/apexGbeConfIfRedundEnable
apexGbeConfIfRedundEnable
OBJECT-TYPE
1.3.6.1.4.1.1166.1.31.7.1.7.2.1.2
Description
Enables GbE Interface Redundancy for ports pair. Failover is based on link status. If the primary GbE fails, the secondary GbE will become active and will start receiving content. There is no data rate comparison, as only one interface in the redundancy pair is active. The secondary GbE cannot be in use prior to enabling redundancy. TS redundancy may not be used at the same time as interface redundancy. Interface redundancy is not applicable when chassis redundancy is enabled. Once written, the change to this table will only take immediate effect after apexGbeConfIfRedundApplyChange is set to 'apply'. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via apexSaveConfig. @Config(config=yes, reboot=no) @Commit(param=apexGbeConfIfRedundApplyChange, value=2) @Save(apexSaveConfig, value=2) @File(gige_red.ini, type='ini')
Syntax
EnableDisableTYPE