1.3.6.1.4.1.1166.1.31.7.1.4.1.3
Access
read-write
Status
current
Source
APEX-MIB
Sub-identifiers
0
This is the enable/disable of automatic switch back from Secondary to Primary for Gigabit Ethernet redundancy. When 'enabled', switch back to the Primary will automatically occur when the Primary is restored. When 'disabled', the user must force back to the Primary using apexGbeConfInRedundForceToPrimary or apexManRteGbeInRedForceSwitch. This parameter applies to all configured redundant pairs. Auto switch back to the primary will not occur if the user forced a failover to the secondary. Auto switch back only occurs after a non-forced failover event. Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via apexSaveConfig. @Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(gige_red.ini, type='ini')
EnableDisableTYPE