MIB Viewer

apexGbeInputDataTsBufferDepth

OBJECT-TYPE
1.3.6.1.4.1.1166.1.31.7.1.1.8
Access
read-write
Status
current
Source
APEX-MIB
Sub-identifiers
0
GBE Input Data stream buffer depth. Amount of time in milliseconds that the GigE will buffer input streams that do not contain PCRs. This allows the GigE to buffer these streams to remove network jitter and then play them out with the packets equally spaced out. The buffer depth must be equal to or greater than the data stream smoothing period. Once written, the change to this parameter will take immediate effect. However, in order for the change to persist through subsequent reboots or power cycles, the change must be saved via the apexSaveConfig parameter. @Config(config=yes, reboot=no) @Save(apexSaveConfig, value=2) @File(bcmr.ini, type='ini')
Integer32(250..650)