MIB Viewer

arrisMtaDevPwrSupplyChargeState

OBJECT-TYPE
1.3.6.1.4.1.4115.1.3.3.1.3.3.6
Access
read-write
Status
current
Sub-identifiers
0
Causes the battery to be charged to the level that is specified by the data. The value of charge is expressed in 10 watt*minutes/count. In order for the battery to be charged to the correct level, issuing this command will cause the charger to enter a discharge/charge cycle. The initial default value for this parameter is 0.8 times the Rated Battery Capacity. This command should be used with discretion. (Only available on MODEL 5 and MODEL 6 modems. Not supported on TM508/512)
Integer32