MIB Viewer

batteryAgingNotification

NOTIFICATION-TYPE
1.3.6.1.2.1.233.0.5
Status
current
Sub-identifiers
0
This notification can be generated when the actual capacity (batteryActualCapacity) falls below a threshold defined by object batteryAlarmLowCapacity or when the charging cycle count of the battery (batteryChargingCycleCount) exceeds the threshold defined by object batteryAlarmHighCycleCount. If the aging has been detected for a single cell or a set of cells of the battery and not for the entire battery, then object batteryCellIdentifier should be set to a value that identifies the cell or set of cells. Otherwise, the value of object batteryCellIdentifier should be set to the empty string when this notification is generated. This notification should not be sent again for the same battery or cell, respectively, before an indication of a maintenance action has been detected, such as a battery disconnection event or a reinitialization of the battery monitoring system.