MIB Viewer

bbChanUpcCDVT

OBJECT-TYPE
1.3.6.1.4.1.351.110.5.2.7.1.1.1.13
Access
read-write
Status
current
Sub-identifiers
0
Compliant Cell Delay Variation. Also known as CDVT(0+1), Cell Delay Variation Tolerance, which specifies the maximum time period for accumulated violations of cell-arrival time parameters. This object applies to the First Leaky bucket for cells with Cell Loss Priority of 0 or 1. . Units: microseconds. . Applicable connection types: UBR, CBR, VBR, ABR . Default: CBR: 10000 Others: 250000
Integer32 (1..5000000)