MIB Viewer

bertLoopbackMask

OBJECT-TYPE
1.3.6.1.4.1.351.110.6.1.28.1.7
Access
read-only
Status
current
Sub-identifiers
0
Every loopback is represented by 2 bits of mask. Bits 0-5 are valid in this integer. The meaning of the mask can be understood from the example below: Loopback | SM | Test Medium | support | Port Far End Loopback | 1 | 1 Facility Loopback | 1 | 1 Metallic Loopback | 1 | 0 (Table contents applicable to FRSM-4T1) bertLoopbackMask = 011111 binary The column titles represent the variables bertLoopback depends on. The mask is represented in column major order.
Integer32