MIB Viewer

biboPPPLayer2Mode

OBJECT-TYPE
1.3.6.1.4.1.272.4.3.1.1.22
Access
read-write
Status
mandatory
Sub-identifiers
0
This object specifies the layer 2 mode to be used for a connection. It is only relevant, if the Encapsulation involves an LAPB protocol. This is the case for x25, x25-ppp, ip-lapb, lapb, x31-bchan, x75-ppp, x75btx-ppp, x25-nosig, v120-ppp. The Default value of this object is auto. For dialup connection, the layer 2 mode will than be DTE, on the calling side and DCE on the called side. For permanent connections, the layer 2 mode is set at lower layers (for example isdnChType in the isdnChTable). When this object is set to dte or dce, the layer 2 mode will always be DTE or DCE, regardless of the call direction or the settings at the lower layer.
INTEGER { auto(1), dte(2), dce(3) }