MIB Viewer

cadCmRemoteQueryPollerInterval

OBJECT-TYPE
1.3.6.1.4.1.4998.1.1.55.1.1.2
Access
read-write
Status
current
Sub-identifiers
0
An interval between two polling cycles of the CMTS CM Poller. The poller will not start the next cycle until it finished polling for the last CM , even though the time has expired. If the cadCmRemoteQueryPollerInterval is too small with a large number of CMs, the poller would tie up the CPU and resources and possibly degrade the system's performance.
Unsigned32(30..86400)