cfgHmsEmsAddressStartTrapAssurance

OBJECT-TYPE
1.3.6.1.4.1.5802.1.3.1.2.2.1.1.1.1.3
Access
read-write
Status
current
Sub-identifiers
0
When this MIB is set to one, additional binding is appended to the cold or warm start Trap (HMS). The EMS must set the bound OID to 1 to acknowledge receipt of the trap. The DHT then uses the cfgEmsTimeout & cfgEmsRetry to resend the trap if necessary.