MIB Viewer

cfgPsMeasurementSource

OBJECT-TYPE
1.3.6.1.4.1.5802.1.3.1.2.2.2.3.6
Access
read-write
Status
current
Sub-identifiers
0
This MIB object allow the user to select the source for the internal measurement on an XM2 power supply. The choice is either to derive the measurement data from the transponder's analog port (analogPort(1)) or from the transponder's digital interface bus (communicationPort(2)). Default value analogPort(1). The value of this MIB will be stored in non-volatile memory.
INTEGER {analogPort(1), communicationPort(2)}