MIB Viewer

channelBLoopback

OBJECT-TYPE
1.3.6.1.4.1.17713.6.7.9
Access
read-only
Status
current
Sub-identifiers
0
The loopback status of telecoms channel B. This is intended for installation testing and should be set to 'None' for normal operation. The wire connections to a unit can be tested by applying a 'Copper' loopback to the local unit. The wireless connection to the remote unit can be tested by applying a 'Wireless' loopback to the remote unit with no loopback on the local unit. NB: a change of state may generate an SNMP trap and/or SMTP email alert
INTEGER { none(0), copper(1), wireless(2) }