MIB Viewer

ciscoICsuDsuSw56kDialingStatus

OBJECT-TYPE
1.3.6.1.4.1.9.9.44.1.3.2.1.1
Access
read-only
Status
current
Sub-identifiers
0
This variable indicates the dialing status of units using switched connections. idle - on-hook and no call in progress. dialing - dialing a number. onLine - Online passing data. noWinkFromSwitch - No wink from switch (cleared after 5 seconds). Wink is a DC signalling method in which the polarity of the line is temporarily reversed and then returned to its original polarity as an acknowledgement. numberBusy - Number is busy (cleared after 5 seconds). noAnswer - No answer. (cleared after 5 seconds).
INTEGER { idle (1), dialing (2), online (3), noWinkFromSwitch (4), numberBusy (5), noAnswer (6) }