MIB Viewer

ciscoTsStackSwitchPwrSupplyStatus

OBJECT-TYPE
1.3.6.1.4.1.9.5.32.2.1.1.30
Access
read-only
Status
mandatory
Sub-identifiers
0
The status of the power supply of the switch. The values have the following meanings: unknown(1) : The status is not known. internal-only(2) : The switch is not capable of redundant power. internal-no-backup(3) : The switch is capable of redundant power, but is currently operating on the internal supply with no RPS attached. internal-backup-will-reset(4) : The switch is capable of redundant power and is currently opertaing on the internal supply. A RPS is attached, but if the internal supply fails there will be a reset. external-no-backup(5) : The switch is capable of redundant power and is currently operating on a single external RPS connection. external-backup-no-reset(6) : The switch is capable of redundant power and is currently operating with a y-connected external RPS. If one supply in the RPS fails there will be no interuption of operation.
INTEGER { unknown(1), internal-only(2), internal-no-backup(3), internal-backup-will-reset(4), external-no-backup(5), external-backup-no-reset(6) }