MIB Viewer

cmgModuleFaultMask

OBJECT-TYPE
1.3.6.1.4.1.6889.2.9.1.1.11.1.1.10
Access
read-only
Status
current
Sub-identifiers
0
Each bit of this value set to '1' indicates a specific fault in the module. Octets are numbered in the order in which they appear in the PDU. Bits are numbered from the most-significant leftmost bit in the octet (bit 0) to the least-significant rightmost bit (bit 7). Cajun numbering continues across octets, so that octet 1 bit 0 is called bit 8 in the Cajun scheme. That number is also shown below, with the octet value for each single bit set. Cajun Octet Octet bit# bit# value Meaning 0 0/0 0x80 Media module is in administrative busy-out. 1 0/1 0x40 One or more ports on this media module is in administrative busy-out. 2 0/2 0x20 Insertion sequence failed. 3 0/3 AWOH data module conflict. 4 0/4 0x08 Media module automatic reset occurred. 5 0/5 0x04 One or more power-on startup tests failed. 6 0/6 0x02 Media module parameter exchange failed. 7 0/7 Unsupported module enrolment. 8-15 1/0-7 Unused.