MIB Viewer

componentPowerDetailsStaticCap

OBJECT-TYPE
1.3.6.1.4.1.2.3.51.2.22.31.6.1.13
Access
read-only
Status
mandatory
Source
CME-MIB
Sub-identifiers
0
Component Module Details Table static capabilities list. This is a list of five power management capabilities that the component may or may not support. The list of power management capabilities is as follow: Power Measurement Power Capping Power Saving Dynamic Power Saving Extended Dynamic Power Saving The returned octet string contains 5 pairs of numeric characters separated by blank characters. Each of these pairs will consist of either '00' or '01'. '00' indicates that the capability is not there, '01' indicates that the capability is present on the component. The 5 pairs represent the capabilities of the 5 types listed above, in order, for this component in the table. Example response: '01 01 00 00 00' This component has the capability of Power Management and Power Capping, but does not support the last three types.
OCTET STRING