MIB Viewer

cpIwfLineSignaling

OBJECT-TYPE
1.20.5.1.1.11
Access
read-write
Status
current
Sub-identifiers
0
This object defines the line signal coding for CAS. It represents four parameters, by two octet (nibble per parameter Bit 7 = MSB, Bit 0 = LSB ) as follows: RINGING Code- MSB nibble, default value is 0000 (h'0) NORMAL Code- 3rd nibble, default value is 0101 (h'5) ONHOOK Code- 2nd nibble, default value is 0101 (h'5) OFFHOOK Code- LSB nibble. default value is 1111 (h'F)
OCTET STRING