MIB Viewer

cpqFcaAccelBatteryStatus

OBJECT-TYPE
1.3.6.1.4.1.232.16.2.2.2.1.6
Access
read-only
Status
mandatory
Sub-identifiers
0
Array Accelerator Board Battery Status. This monitors the status of each battery pack on the board. The batteries can only recharge when the system has power applied. The following values are valid: Other (1) Indicates that the instrument agent does not recognize battery status. You may need to update your software. Ok (2) Indicates that a particular battery pack is fully charged. Charging (3) The battery power is less than 75%. The array controller is attempting to recharge the battery. A battery can take as long as 36 hours to fully recharge. After 36 hours, if the battery has not recharged, it is considered failed. Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Array Accelerator board needs to be serviced. Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly. Your Array Accelerator board should be serviced as soon as possible. NotPresent (6) There are no batteries associated with this controller.
INTEGER { other(1), ok(2), recharging(3), failed(4), degraded(5), notPresent(6) }