iso/org/dod/internet/private/enterprises/.232/.6/.2/.6/cpqHeTemperatureTable/cpqHeTemperatureEntry/cpqHeTemperatureThresholdType
cpqHeTemperatureThresholdType
OBJECT-TYPE
1.3.6.1.4.1.232.6.2.6.8.1.7
Description
This specifies the type of this instance of temperature sensor. This value will be one of the following: other(1) Temperature threshold type could not be determined. blowout(5) If a blowout(5) temperature sensor reaches its threshold, the fan or fans in the area of the temperature sensor will increase in speed in an attempt to reduce the temperature before a caution or critical threshold is reached. caution(9) If a caution(9) temperature sensor reaches its threshold, the cpqHeTemperatureCondition will be set to degraded(3) and the system will either continue or shutdown depending on the setting of cpqHeThermalDegradedAction. critical(15) If a critical(15) temperature sensor reaches its threshold, the cpqHeTemperatureCondition will be set to failed(4) and the system will shutdown. noreaction(16) this value will be defined when a threshold value is zero and system will not react on those sensor as those threshold sensors are meant for display purpose only.
Syntax
INTEGER { other(1), blowout(5), caution(9), critical(15), noreaction(16) }