MIB Viewer

dpPoeIfDetectStatus

OBJECT-TYPE
1.3.6.1.4.1.171.15.11.1.1.2.1.1.1
Access
read-only
Status
current
Sub-identifiers
0
This object indicates the operational status of the port PD detection. disabled(1) - PSE function is disabled. searching(2) - Remote PD is not connected. requesting(3) - Remote PD is inserted, but the PSE doesn't provide power yet. delivering(4) - Remote PD is now powering by PoE system. faulty(5) - Device detection or a powered device is in a faulty state.
INTEGER { disabled(1), searching(2), requesting(3), delivering(4), faulty(5) }