MIB Viewer

dsMplsPwCCType

OBJECT-TYPE
1.3.6.1.4.1.6296.9.1.1.2.28.1.3.1.1.2
Access
read-create
Status
current
Sub-identifiers
0
This variable indicates the CC type for VCCV negotiation. The CC type shall be control word (0x01) or router alert label (0x02) or pw-ttl (0x04) or combination of all three. Find below the value for configuring the CC type value with all the combination. 1 - Control word 2 - Router Alert Label 3 - Control word and Router Alert Label 4 - pw TTL 5 - Control word and pw TTL 6 - Router Alert Label and pw TTL 7 - Control word and Router Alert Label and pw TTL.
INTEGER (1..7)