MIB Viewer

dsx3PCV24HrThreshold

OBJECT-TYPE
1.3.6.1.4.1.351.110.4.4.1.2.1.1.17
Access
read-write
Status
current
Sub-identifiers
0
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval This object is not supported in CESM-T3/E3. This object is not applicable for E3 interface.
Integer32 (0..2147483647)