MIB Viewer

fileServicesAction

OBJECT-TYPE
1.3.6.1.4.1.2544.1.12.2.1.8.1
Access
read-write
Status
current
Sub-identifiers
0
This object is write only. Setting this object initiates a file transfer Supported actions are: get-database(1) - Copy a backup database from a remote server and place it in the staging area. (See databaseAction) put-database(2) - Copy a backup database to a remote server. (See databaseAction) software-copy(3) - Transfer a software image file to the system and write it to the standby partition. get-sys-database(4) - Copy a system database from a remote server and place it in the staging area. (See databaseAction) put-sys-database(5) - Copy a system database to a remote server. (See databaseAction) get-defaultsvalue-file(6) - Transfer the Defaults Value file to the system. put-sysresetdebuginfo-file(7) - Transfer the System Reset Debug Information file to a remote server. put-securitylog-file(8) - Transfer the System Security Log Information file to a remote server. put-alarmlog-file(9) - Transfer the System Alarm Log Information file to a remote server. put-audit-file(10) - Transfer the System Audit Log Information file to a remote server. get-config-file(11) - Transfer the Configuration File from a remote server. put-config-file(12) - Transfer the Configuration File to a remote server. put-sat-result(13) - Transfer the SAT test result file to a remote server.
INTEGER { not-applicable(0), get-database(1), put-database(2), software-copy(3), get-sys-database(4), put-sys-database(5), get-defaultsvalue-file(6), put-sysresetdebuginfo-file(7), put-securitylog-file(8), put-alarmlog-file(9), put-auditlog-file(10), get-config-file(11), put-config-file(12), put-sat-result(13) }