MIB Viewer

fsErpsRingConfigGuardTime

OBJECT-TYPE
1.3.6.1.4.1.10876.101.2.40.2.3.1.2
Access
read-write
Status
current
Sub-identifiers
0
This object is used to configure the period for the guard timer of this ring. This timer is required to prevent reception of outdated R-APS messages. Guard timer will be started on reception of local clear SF event. R-APS messages (except R-APS event messages) received during the running of the guard timer will be discarded. The configured value of this timer is applicable only from the next start/re-start of the timer. The guard timer has a period from 0 to 1 hour, configurable in units of 1 millisecond. For example, to configure GuardTime as 1 second, configure the value as 1000.
Unsigned32 (0..3600000)