MIB Viewer

genEquipRadioCfgLinkShutDownOnRadioFailure

OBJECT-TYPE
1.3.6.1.4.1.2281.10.7.2.1.21
Access
read-write
Status
mandatory
Sub-identifiers
0
This parameter enables shutting down the link and initiating automatic state propagation upon a failure in each one of the radios. Radio failure condition is determined by user configurations and can be one of the following: Radio LOF, Link ID mismatch, Radio excessive BER, Radio signal degrade, Link ID mismatch.
EnableDisable